LRD02 Schneider Electric Industrial Automation Components

LRD02 on Powermatic Associates
Schneider Electric

Part#:LRD02

Manufacturer:Schneider Electric

Category:Industrial Automation Components

Product Lifecycle:Active

Product description

Schneider Electric LRD02, part of the LRD sub-range, features a differential thermal overload relay with a Class 10A protection function. It is designed for a 3 Pole configuration and supports a rated current of 0.16-0.25 A. The protection settings for thermal overload are adjustable between 0.16-0.25A. This part includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. Connection types include direct to contactor for upstream connections and screw-clamp for outgoing cables and the control circuit. The rated voltage for AC phase-to-phase, applicable up to 400Hz, is 690 V. The minimum and maximum currents are set at 0.16 A and 0.25 A, respectively.

Product Details

  • Height
    2.60 in (66 mm)
  • Thermal Overload Class
    Class 10A IEC 60947-4-1
  • [Ue] Rated Operational Voltage
    690 V AC 0...400 Hz power circuit IEC 60947-4-1
  • Thermal Protection Adjustment Range
    0.16…0.25 A
  • Phase Failure Sensitivity
    Tripping current 130 % of Ir on two phase, the last one at 0
  • Relay Application
    Motor protection
  • Product Name
    TeSys LRD
  • Tripping Threshold
    1.14 +/- 0.06 Ir IEC 60947-4-1
  • Range
    TeSys
  • Auxiliary Contact Composition
    1 NO + 1 NC
  • Product Or Component Type
    Differential thermal overload relay
  • [Uimp] Rated Impulse Withstand Voltage
    6 kV
  • Width
    1.77 in (45 mm)
  • [Ith] Conventional Free Air Thermal Current
    5 A signalling circuit
  • Depth
    2.76 in (70 mm)
  • Device Short Name
    LRD
  • Network Frequency
    0...400 Hz
  • Temperature Compensation
    -4…140 °F (-20…60 °C)
  • Net Weight
    0.27 lb(US) (0.124 kg)
  • Network Type
    DC AC
  • Permissible Current
    3 A 120 V AC-15 signalling circuit 0.22 A 125 V DC-13 signalling circuit
  • Control Type
    Red push-button stop Blue push-button reset
  • Tightening Torque
    Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals
  • Associated Fuse Rating
    4 A gG signalling circuit 4 A BS signalling circuit
  • Mounting Support
    Plate, with specific accessories Rail, with specific accessories Under contactor
  • [Ui] Rated Insulation Voltage
    Power circuit 600 V CSA Power circuit 600 V UL Power circuit 690 V IEC 60947-4-1
  • Connections - Terminals
    Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible without cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 m
  • Product Compatibility
    LC1D25 LC1D38 LC1D12 LC1D09 LC1D18 LC1D32

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LRD02 on Powermatic Associates is $96.23. Order now.



Similar products from: Schneider Electric Industrial Automation Components

Manufacturer warranty

LRD02 Schneider Electric

$96.23

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$96.23

$96.23 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare LRD02 with other Industrial Automation Components products

Height

Thermal Overload Class

[Ue] Rated Operational Vo...

Thermal Protection Adjust...

Phase Failure Sensitivity

Relay Application

Product Name

Tripping Threshold

Range

Auxiliary Contact Composi...

Selected product

LRD02
Backordered
LRD02
Schneider Electric

Schneider Electric LRD02, part of the LRD sub-range, features a differential thermal overload relay ...

Height2.60 in (66 mm)

Thermal Overload ClassClass 10A IEC 60947-4-1

[Ue] Rated Operational Voltage690 V AC 0...400 Hz power ci...

Thermal Protection Adjustment Range0.16…0.25 A

Phase Failure SensitivityTripping current 130 % of Ir...

Relay ApplicationMotor protection

Product NameTeSys LRD

Tripping Threshold1.14 +/- 0.06 Ir IEC 60947-4...

RangeTeSys

Auxiliary Contact Composition1 NO + 1 NC

LR9D08
1 in stock
LR9D08
Schneider Electric

Schneider Electric LR9D08 is an electronic thermal overload relay designed for direct connection to ...

Height-

Thermal Overload ClassClass 5…30

[Ue] Rated Operational Voltage-

Thermal Protection Adjustment Range1.6…8 A

Phase Failure Sensitivity-

Relay ApplicationMotor protection

Product NameTeSys LRD

Tripping Threshold-

RangeTeSys

Auxiliary Contact Composition-

M9F23204
3 in stock
M9F23204
Schneider Electric

Schneider Electric M9F23204 is a Miniature Circuit Breaker (MCB) within the C60SP sub-range, designe...

Height-

Thermal Overload Class-

[Ue] Rated Operational Voltage-

Thermal Protection Adjustment Range-

Phase Failure Sensitivity-

Relay Application-

Product NameMulti 9 C60

Tripping Threshold-

RangeMulti 9

Auxiliary Contact Composition-

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

Recently viewed products

Relevant products

FAQ

What is the price of LRD02?
Purchase the LRD02 from Powermatic Associates at the price of $96.23. Order today.

Out if stock but available for backorder.

Schneider Electric LRD02, part of the LRD sub-range, features a differential thermal overload relay with a Class 10A protection function. It is designed for a 3 Pole configuration and supports a rated current of 0.16-0.25 A. The protection settings for thermal overload are adjustable between 0.16-0.25A. This part includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. Connection types include direct to contactor for upstream connections and screw-clamp for outgoing cables and the control circuit. The rated voltage for AC phase-to-phase, applicable up to 400Hz, is 690 V. The minimum and maximum currents are set at 0.16 A and 0.25 A, respectively.

Similar products from: Industrial Automation Components

What can I help you find today?

Recommended parts