LRD02 Schneider Electric Industrial Automation Components


Part#:LRD02
Manufacturer:Schneider Electric
Category:Industrial Automation Components
Product Lifecycle:Active
Product description
Schneider Electric LRD02, part of the LRD sub-range, features a differential thermal overload relay with a Class 10A protection function. It is designed for a 3 Pole configuration and supports a rated current of 0.16-0.25 A. The protection settings for thermal overload are adjustable between 0.16-0.25A. This part includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. Connection types include direct to contactor for upstream connections and screw-clamp for outgoing cables and the control circuit. The rated voltage for AC phase-to-phase, applicable up to 400Hz, is 690 V. The minimum and maximum currents are set at 0.16 A and 0.25 A, respectively.
Product Details
- Height 2.60 in (66 mm)
- Thermal Overload Class Class 10A IEC 60947-4-1
- [Ue] Rated Operational Voltage 690 V AC 0...400 Hz power circuit IEC 60947-4-1
- Thermal Protection Adjustment Range 0.16…0.25 A
- Phase Failure Sensitivity Tripping current 130 % of Ir on two phase, the last one at 0
- Relay Application Motor protection
- Product Name TeSys LRD
- Tripping Threshold 1.14 +/- 0.06 Ir IEC 60947-4-1
- Range TeSys
- Auxiliary Contact Composition 1 NO + 1 NC
- Product Or Component Type Differential thermal overload relay
- [Uimp] Rated Impulse Withstand Voltage 6 kV
- Width 1.77 in (45 mm)
- [Ith] Conventional Free Air Thermal Current 5 A signalling circuit
- Depth 2.76 in (70 mm)
- Device Short Name LRD
- Network Frequency 0...400 Hz
- Temperature Compensation -4…140 °F (-20…60 °C)
- Net Weight 0.27 lb(US) (0.124 kg)
- Network Type DC AC
- Permissible Current 3 A 120 V AC-15 signalling circuit 0.22 A 125 V DC-13 signalling circuit
- Control Type Red push-button stop Blue push-button reset
- Tightening Torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals
- Associated Fuse Rating 4 A gG signalling circuit 4 A BS signalling circuit
- Mounting Support Plate, with specific accessories Rail, with specific accessories Under contactor
- [Ui] Rated Insulation Voltage Power circuit 600 V CSA Power circuit 600 V UL Power circuit 690 V IEC 60947-4-1
- Connections - Terminals Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible without cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 m
- Product Compatibility LC1D25 LC1D38 LC1D12 LC1D09 LC1D18 LC1D32
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LRD02 on Powermatic Associates is $96.23. Order now.
LRD02 Related Documents
Similar products from: Schneider Electric Industrial Automation Components
Manufacturer warranty
LRD02 Schneider Electric
$96.23
Your price can be lower.
Log in or Create account to check your discount
Select Qty:
$96.23
$96.23 each
Average response time: 11 minutes
Worldwide Shipping and Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare LRD02 with other Industrial Automation Components products
Height
Thermal Overload Class
[Ue] Rated Operational Vo...
Thermal Protection Adjust...
Phase Failure Sensitivity
Relay Application
Product Name
Tripping Threshold
Range
Auxiliary Contact Composi...
Selected product

LRD02
Schneider Electric
Schneider Electric LRD02, part of the LRD sub-range, features a differential thermal overload relay ...
Height2.60 in (66 mm)
Thermal Overload ClassClass 10A IEC 60947-4-1
[Ue] Rated Operational Voltage690 V AC 0...400 Hz power ci...
Thermal Protection Adjustment Range0.16…0.25 A
Phase Failure SensitivityTripping current 130 % of Ir...
Relay ApplicationMotor protection
Product NameTeSys LRD
Tripping Threshold1.14 +/- 0.06 Ir IEC 60947-4...
RangeTeSys
Auxiliary Contact Composition1 NO + 1 NC
About the manufacturer
Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...
Recently viewed products
Relevant products
FAQ
What is the price of LRD02?
Purchase the LRD02 from Powermatic Associates at the price of $96.23. Order today.
Out if stock but available for backorder.
Schneider Electric LRD02, part of the LRD sub-range, features a differential thermal overload relay with a Class 10A protection function. It is designed for a 3 Pole configuration and supports a rated current of 0.16-0.25 A. The protection settings for thermal overload are adjustable between 0.16-0.25A. This part includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. Connection types include direct to contactor for upstream connections and screw-clamp for outgoing cables and the control circuit. The rated voltage for AC phase-to-phase, applicable up to 400Hz, is 690 V. The minimum and maximum currents are set at 0.16 A and 0.25 A, respectively.
Similar products from: Industrial Automation Components
What can I help you find today?