Schneider Electric M9F52140 is a Miniature Circuit Breaker (MCB) within the C60BPR sub-range, designed to comply with UL489 standards. This MCB features a single pole configuration and is rated for a current of 40A. It has a rated insulation voltage (Ui) of 500 V and a rated impulse voltage (Uimp) of 6 kV. The short circuit breaking rating is specified as 10kA AIR for 120Vac, 240Vac, and 60Vdc. The rated voltage for AC phase-to-phase connections is 440 V. This model protects a single pole and is characterized by a C tripping curve.

Product Details

  • Breaking Capacity
    3 kA Icu 415 V AC EN/IEC 60947-2 10 kA Icu 240 V AC EN/IEC 60947-2 20 kA Icu 60 V DC EN/IEC 60947-2 3 kA Icu 415 V AC GB 14048.2 10 kA Icu 240 V AC GB 14048.2 20 kA Icu 60 V DC GB 14048.2 10 kA AIR 60 V DC UL 489 10 kA A
  • [Ics] Rated Service Breaking Capacity
    2.25 kA 75 % EN/IEC 60947-2 - 415 V AC 7.5 kA 75 % EN/IEC 60947-2 - 240 V AC 2.25 kA 75 % GB 14048.2 - 415 V AC 7.5 kA 75 % GB 14048.2 - 240 V AC 15 kA 75 % GB 14048.2 - 60 V DC 15 kA 75 % EN/IEC 60947-2 - 60 V DC
  • Standards
    EN/IEC 60947-2 GB 14048.2 UL 489 CSA C22.2 No 5
  • Product Certifications
    IEC CCC CSA UL
  • [Ue] Rated Operational Voltage
    240 V AC 50/60 Hz 415 V AC 50/60 Hz 60 V DC
  • Magnetic Tripping Limit
    8.5 x In +/- 20 % AC 12 x In +/- 20 % DC
  • Network Type
    AC DC
  • Earth-Leakage Protection
    Without
  • Tightening Torque
    17.70 lbf.in (2 N.m) top or bottom
  • Connections - Terminals
    Ring terminal top or bottom)
  • Provision For Padlocking
    Padlockable
  • Depth
    2.83 in (72 mm)
  • Color
    Gray
  • Electrical Durability
    10000 cycles
  • 9 Mm Pitches
    2
  • Height
    5.00 in (127 mm)
  • Contact Position Indicator
    Yes
  • Mechanical Durability
    20000 cycles
  • Width
    0.71 in (18 mm)
  • Mounting Mode
    Clip-on
  • Local Signalling
    ON/OFF indication
  • Mounting Support
    DIN rail
  • [Uimp] Rated Impulse Withstand Voltage
    6 kVEN/IEC 60947-2
  • [Ui] Rated Insulation Voltage
    500 V AC EN/IEC 60947-2
  • Product Or Component Type
    Miniature circuit-breaker
  • Control Type
    Toggle
  • Suitability For Isolation
    Yes EN/IEC 60947-2
  • Curve Code
    C
  • Trip Unit Technology
    Thermal-magnetic
  • Poles Description
    1P
  • Number Of Protected Poles
    1
  • Device Short Name
    C60BPR
  • Line Rated Current
    40 A 77 °F (25 °C) EN/IEC 60947-2
  • Product Name
    Multi 9 C60
  • Device Application
    Distribution
  • Range
    Multi 9

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of M9F52140 on Powermatic Associates is $126.00. Order now.



Similar products from: Schneider Electric Industrial Automation Components

Manufacturer warranty

M9F52140 Schneider Electric

$126.00

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$126.00

$126.00 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare M9F52140 with other Industrial Automation Components products

Breaking Capacity

[Ics] Rated Service Break...

Standards

Product Certifications

[Ue] Rated Operational Vo...

Magnetic Tripping Limit

Network Type

Earth-Leakage Protection

Tightening Torque

Connections - Terminals

Selected product

M9F52140
Backordered
M9F52140
Schneider Electric

Schneider Electric M9F52140 is a Miniature Circuit Breaker (MCB) within the C60BPR sub-range, design...

Breaking Capacity3 kA Icu 415 V AC EN/IEC 609...

[Ics] Rated Service Breaking Capacity2.25 kA 75 % EN/IEC 60947-2 ...

StandardsEN/IEC 60947-2 GB 14048.2 UL...

Product CertificationsIEC CCC CSA UL

[Ue] Rated Operational Voltage240 V AC 50/60 Hz 415 V AC 5...

Magnetic Tripping Limit8.5 x In +/- 20 % AC 12 x In...

Network TypeAC DC

Earth-Leakage ProtectionWithout

Tightening Torque17.70 lbf.in (2 N.m) top or ...

Connections - TerminalsRing terminal top or bottom)

M9F22163
5 in stock
M9F22163
Schneider Electric

Schneider Electric M9F22163 is a Miniature Circuit Breaker (MCB) within the C60SP sub-range, designe...

Breaking Capacity-

[Ics] Rated Service Breaking Capacity-

Standards-

Product Certifications-

[Ue] Rated Operational Voltage-

Magnetic Tripping Limit-

Network TypeAC DC

Earth-Leakage Protection-

Tightening Torque-

Connections - Terminals-

M9F52130
1 in stock
M9F52130
Schneider Electric

Schneider Electric M9F52130 is a Miniature Circuit Breaker (MCB) within the C60BPR sub-range, design...

Breaking Capacity-

[Ics] Rated Service Breaking Capacity-

Standards-

Product Certifications-

[Ue] Rated Operational Voltage-

Magnetic Tripping Limit-

Network TypeDC AC

Earth-Leakage Protection-

Tightening Torque-

Connections - Terminals-

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

Recently viewed products

Relevant products

FAQ

What is the price of M9F52140?
Purchase the M9F52140 from Powermatic Associates at the price of $126.00. Order today.

Out if stock but available for backorder.

Schneider Electric M9F52140 is a Miniature Circuit Breaker (MCB) within the C60BPR sub-range, designed to comply with UL489 standards. This MCB features a single pole configuration and is rated for a current of 40A. It has a rated insulation voltage (Ui) of 500 V and a rated impulse voltage (Uimp) of 6 kV. The short circuit breaking rating is specified as 10kA AIR for 120Vac, 240Vac, and 60Vdc. The rated voltage for AC phase-to-phase connections is 440 V. This model protects a single pole and is characterized by a C tripping curve.

Similar products from: Industrial Automation Components

What can I help you find today?

Recommended parts