Schneider Electric - BDA34060Y6

Product Details

  • Breaking Capacity
    25 kA 208Y/120 V AC 50/60 Hz UL 489 25 kA 240 V AC 50/60 Hz UL 489 18 kA 480/277 V AC 50/60 Hz UL 489 18 kA 480 V AC 50/60 Hz UL 489 14 kA 600Y/347 V AC 50/60 Hz UL 489 10 kA 250 V DC UL 489
  • [Ics] Rated Service Breaking Capacity
    25 kA 220...240 V AC 50/60 Hz IEC 60947-2 14 kA 500...525 V AC 50/60 Hz IEC 60947-2 18 kA 380...415 V AC 50/60 Hz IEC 60947-2 18 kA 440 V AC 50/60 Hz IEC 60947-2
  • Number Of Slots
    1 auxiliary switch OF plug-in) 1 voltage release MN or MX plug-in) 1 alarm switch SD plug-in)
  • Electrical Connection
    I-Line connection line Lugs load
  • Tightening Torque
    31.86…38.94 lbf.in (3.6…4.4 N.m) 0.00…0.01 in² (2.5…6 mm²) (AWG 14...AWG 10) 44.25…54.87 lbf.in (5…6.2 N.m) 0.02…0.11 in² (10…70 mm²) (AWG 8...AWG 2/0)
  • Quantity Per Set
    Set of 1
  • Net Weight
    2.90 lb(US) (1.315 kg)
  • Local Signalling
    for presence of auxiliary contacts flag (green)
  • Phase Connection
    CBA
  • Depth
    3.50 in (89 mm)
  • Width
    3.19 in (81 mm)
  • Height
    5.39 in (137 mm)
  • 9 Mm Pitches
    9
  • Mounting Height
    4.49 in (114 mm)
  • Power Wire Stripping Length
    0.79 in (20 mm)
  • Color
    Gray RAL 7016)
  • Mounting Mode
    I-Line
  • AWG Gauge
    AWG 14...AWG 2/0 aluminium/copper
  • Connection Pitch
    1.06 in (27 mm)
  • Mechanical Durability
    20000 cycles IEC 947-1 Annex K ed 5.2
  • Electrical Durability
    10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
  • Utilisation Category
    Category A
  • [Ui] Rated Insulation Voltage
    800 V IEC 60947-2
  • Suitability For Isolation
    Yes conforming to IEC 60947-2
  • [Uimp] Rated Impulse Withstand Voltage
    8 kV IEC 60947-2
  • Continuous Current Rating
    80 %
  • Trip Unit Technology
    Thermal-magnetic
  • [Ue] Rated Operational Voltage
    525 V AC 50/60 Hz UL 489
  • Breaking Capacity Code
    D
  • Control Type
    Toggle
  • Device Short Name
    BD 060
  • Product Name
    PowerPact B
  • Device Application
    Distribution
  • Line Rated Current
    60 A
  • Product Or Component Type
    Circuit breaker
  • Number Of Poles
    3P
  • Range
    PowerPact

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Similar products from: Schneider Electric Industrial Automation Components

Manufacturer warranty

BDA34060Y6 Schneider Electric

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare BDA34060Y6 with other Industrial Automation Components products

Breaking Capacity

[Ics] Rated Service Break...

Number Of Slots

Electrical Connection

Tightening Torque

Quantity Per Set

Net Weight

Local Signalling

Phase Connection

Depth

Selected product

BDA34060Y6
Backordered
BDA34060Y6
Schneider Electric

Schneider Electric - BDA34060Y6

Breaking Capacity25 kA 208Y/120 V AC 50/60 Hz...

[Ics] Rated Service Breaking Capacity25 kA 220...240 V AC 50/60 H...

Number Of Slots1 auxiliary switch OF plug-i...

Electrical ConnectionI-Line connection line Lugs ...

Tightening Torque31.86…38.94 lbf.in (3.6…4.4 ...

Quantity Per SetSet of 1

Net Weight2.90 lb(US) (1.315 kg)

Local Signallingfor presence of auxiliary co...

Phase ConnectionCBA

Depth3.50 in (89 mm)

BDL36020
16 in stock
BDL36020
Schneider Electric

Square D by Schneider Electric BDL36020 is a Moulded Case Circuit Breaker (MCCB) within the PowerPac...

Breaking Capacity25 kA 208Y/120 V AC 50/60 Hz...

[Ics] Rated Service Breaking Capacity25 kA 220...240 V AC 50/60 H...

Number Of Slots-

Electrical Connection-

Tightening Torque-

Quantity Per Set-

Net Weight-

Local Signalling-

Phase Connection-

Depth-

BDF36015
4 in stock
BDF36015
Schneider Electric

Square D by Schneider Electric BDF36015 is a Moulded Case Circuit Breaker (MCCB) within the PowerPac...

Breaking Capacity25 kA 208Y/120 V AC 50/60 Hz...

[Ics] Rated Service Breaking Capacity25 kA 220...240 V AC 50/60 H...

Number Of Slots-

Electrical Connection-

Tightening Torque-

Quantity Per Set-

Net Weight-

Local Signalling-

Phase Connection-

Depth-

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

Recently viewed products

Relevant products

BDA34110Y on Powermatic Associates

BDA34110Y

Verified stock: 0

Square D by Schneider Electric BDA34110Y is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDA sub-range, featuring a PowerPact B-Frame 125 TMD design for 3-phase applications with a 110A rating at 480Y/277Vac and an 18kA interrupting capacity. It is equipped with an I-line connection for ABC phases, offering an IP40 degree of protection. This MCCB has a rated impulse voltage of 8 kV and supports a rated current of 110A with a mechanical durability of 20,000 operations when unloaded. It is designed for mounting on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism, ensuring a robust attachment. The unit has three poles (3P), with dimensions of 137 mm in height, 89 mm in depth, and 81 mm in width. It falls under utilisation category A and features over-current protection fixed at 110A, short-circuit hold current protection fixed at 1000A, and short-circuit trip current protection fixed at 1500A. The rated voltage for DC applications is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. Protection functions include thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 110 AT. Its electrical durability with load is rated for 10,000 operations at 440Vac. The frame current rating is 125 AF, and it operates via a toggle (manual) mechanism. The short circuit breaking rating varies by voltage, with 25kA at 240Vac, 18kA at both 480Vac and 480Y/277Vac, 14kA at 600Y/347Vac, and 10kA at 250Vdc, according to UL489 standards. The trip unit employs a thermal-magnetic technology without a display.

Schneider Electric

FAQ

Out if stock but available for backorder.

Schneider Electric - BDA34060Y6

Similar products from: Industrial Automation Components

What can I help you find today?

Recommended parts