Product description

Schneider Electric LC1D386M7 is a magnetic contactor from the Deca sub-range, designed with ring-lugs connections and three poles (3P; 3NO). It has a rated current of 50A for AC-1 and 38A for 440Vac in AC-3 conditions. This contactor is suitable for DIN rail mounting and has a net width of 45 mm. It offers a degree of protection of IP20 and operates within control voltage ranges of 176-242Vac at 50Hz and 187-242Vac at 60Hz, with a nominal voltage of 220Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV, and it can handle rated active power ranging from 9kW at 220-230Vac to 18.5kW at 660-690Vac in AC-3 conditions. It also features 1 normally closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) varies from 2HP at 115Vac in single-phase to 25HP at 575-600Vac in three-phase, according to UL/CSA standards. Its mechanical durability is rated at 15 million operations at no load, and its electrical durability is rated at 1.4 million operations with load. The rated voltage for phase-to-phase is 690 V.

Product Details

  • Device Short Name
    LC1D
  • Product Name
    TeSys D
  • Rated Breaking Capacity
    550 A 440 V power circuit IEC 60947
  • Power Pole Contact Composition
    3 NO
  • Average Impedance
    2 mOhm - Ith 50 A 50 Hz power circuit
  • Auxiliary Contact Composition
    1 NO + 1 NC
  • Insulation Resistance
    > 10 MOhm signalling circuit
  • Poles Description
    3P
  • Range
    TeSys
  • Maximum Operating Rate
    3600 cyc/h 140 °F (60 °C)
  • Control Circuit Type
    AC 50/60 Hz
  • Product Or Component Type
    Contactor
  • Overvoltage Category
    III
  • [Uimp] Rated Impulse Withstand Voltage
    6 kV IEC 60947
  • [Uc] Control Circuit Voltage
    220 V AC 50/60 Hz
  • Heat Dissipation
    2…3 W 50/60 Hz
  • Coil Technology
    Without built-in suppressor module
  • Front Cover
    With
  • Minimum Switching Current
    5 mA signalling circuit
  • Mechanical Durability
    15 Mcycles
  • Signalling Circuit Frequency
    25...400 Hz
  • Minimum Switching Voltage
    17 V signalling circuit
  • [Ue] Rated Operational Voltage
    Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
  • [Ie] Rated Operational Current
    50 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit 38 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
  • Hold-In Power Consumption In VA
    7.5 VA 60 Hz 0.3 68 °F (20 °C)) 7 VA 50 Hz 0.3 68 °F (20 °C))
  • Non-Overlap Time
    1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
  • Mounting Support
    Rail Plate
  • Electrical Durability
    1.4 Mcycles 50 A AC-1 <= 440 V 1.4 Mcycles 38 A AC-3 <= 440 V
  • Safety Reliability Level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Power Dissipation Per Pole
    5 W AC-1 3 W AC-3
  • Contactor Application
    Resistive load Motor control
  • Operating Time
    4...19 ms opening 12...22 ms closing
  • [Ith] Conventional Free Air Thermal Current
    10 A 140 °F (60 °C) signalling circuit 50 A 140 °F (60 °C) power circuit
  • Inrush Power In VA
    70 VA 60 Hz 0.75 68 °F (20 °C)) 70 VA 50 Hz 0.75 68 °F (20 °C))
  • Auxiliary Contacts Type
    Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
  • Connections - Terminals
    Control circuit lugs-ring terminals 0.31 in (8 mm)) Power circuit lugs-ring terminals 0.39 in (10 mm))
  • Associated Fuse Rating
    10 A gG signalling circuit IEC 60947-5-1 63 A gG <= 690 V type 1 power circuit 63 A gG <= 690 V type 2 power circuit
  • Irms Rated Making Capacity
    140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 550 A 440 V power circuit IEC 60947
  • Utilisation Category
    AC-4 AC-1 AC-3
  • Control Circuit Voltage Limits
    0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
  • Tightening Torque
    Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 22.13 lbf.in (2.5 N.m) lugs-ring terminals flat Ø 8 mm M4 Power circuit 2
  • Motor Power HP (UL / CSA)
    10 hp 230/240 V at AC 50/60 Hz for 3 phase 10 hp 200/208 V at AC 50/60 Hz for 3 phase 5 hp 240 V at AC 50/60 Hz for 1 phase 20 hp 480 V at AC 50/60 Hz for 3 phase 25 hp 600 V at AC 50/60 Hz for 3 phase
  • Standards
    CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
  • Motor Power Kw
    18.5 kW 500 V AC 50/60 Hz AC-3) 18.5 kW 660...690 V AC 50/60 Hz AC-3) 7.5 kW 400 V AC 50/60 Hz AC-4) 18.5 kW 380...400 V AC 50/60 Hz AC-3) 9 kW 220...230 V AC 50/60 Hz AC-3) 18.5 kW 415...440 V AC 50/60 Hz AC-3)
  • [Ui] Rated Insulation Voltage
    Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 690 V IEC 60947-4-1
  • [Icw] Rated Short-Time Withstand Current
    60 A 104 °F (40 °C) - 10 min power circuit 430 A 104 °F (40 °C) - 1 s power circuit 150 A 104 °F (40 °C) - 1 min power circuit 310 A 104 °F (40 °C) - 10 s power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circ
  • Product Certifications
    LROS (Lloyds register of shipping) GOST RINA BV GL CCC CSA DNV UL

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LC1D386M7 on Powermatic Associates is $243.60. Order now.



Similar products from: Schneider Electric Industrial Automation Components

Manufacturer warranty

LC1D386M7 Schneider Electric

$243.60

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$243.60

$243.60 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare LC1D386M7 with other Industrial Automation Components products

Device Short Name

Product Name

Rated Breaking Capacity

Power Pole Contact Compos...

Average Impedance

Auxiliary Contact Composi...

Insulation Resistance

Poles Description

Range

Maximum Operating Rate

Selected product

LC1D386M7
Backordered
LC1D386M7
Schneider Electric

Schneider Electric LC1D386M7 is a magnetic contactor from the Deca sub-range, designed with ring-lug...

Device Short NameLC1D

Product NameTeSys D

Rated Breaking Capacity550 A 440 V power circuit IE...

Power Pole Contact Composition3 NO

Average Impedance2 mOhm - Ith 50 A 50 Hz powe...

Auxiliary Contact Composition1 NO + 1 NC

Insulation Resistance> 10 MOhm signalling circuit

Poles Description3P

RangeTeSys

Maximum Operating Rate3600 cyc/h 140 °F (60 °C)

LC1D40ABD
2 in stock
LC1D40ABD
Schneider Electric

Schneider Electric LC1D40ABD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM)...

Device Short NameLC1D

Product NameTeSys D

Rated Breaking Capacity-

Power Pole Contact Composition3 NO

Average Impedance-

Auxiliary Contact Composition-

Insulation Resistance-

Poles Description3P

RangeTeSys

Maximum Operating Rate-

LC1D50A6BD
2 in stock
LC1D50A6BD
Schneider Electric

Schneider Electric LC1D50A6BD is a magnetic contactor from the Deca sub-range, featuring an EverLink...

Device Short NameLC1D

Product NameTeSys D

Rated Breaking Capacity-

Power Pole Contact Composition3 NO

Average Impedance-

Auxiliary Contact Composition-

Insulation Resistance-

Poles Description3P

RangeTeSys

Maximum Operating Rate-

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

Recently viewed products

Relevant products

FAQ

What is the price of LC1D386M7?
Purchase the LC1D386M7 from Powermatic Associates at the price of $243.60. Order today.

Out if stock but available for backorder.

Schneider Electric LC1D386M7 is a magnetic contactor from the Deca sub-range, designed with ring-lugs connections and three poles (3P; 3NO). It has a rated current of 50A for AC-1 and 38A for 440Vac in AC-3 conditions. This contactor is suitable for DIN rail mounting and has a net width of 45 mm. It offers a degree of protection of IP20 and operates within control voltage ranges of 176-242Vac at 50Hz and 187-242Vac at 60Hz, with a nominal voltage of 220Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV, and it can handle rated active power ranging from 9kW at 220-230Vac to 18.5kW at 660-690Vac in AC-3 conditions. It also features 1 normally closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) varies from 2HP at 115Vac in single-phase to 25HP at 575-600Vac in three-phase, according to UL/CSA standards. Its mechanical durability is rated at 15 million operations at no load, and its electrical durability is rated at 1.4 million operations with load. The rated voltage for phase-to-phase is 690 V.

Similar products from: Industrial Automation Components

What can I help you find today?

Recommended parts