BGA261251 Schneider Electric Industrial Automation Components


Part#:BGA261251
Manufacturer:Schneider Electric
Category:Industrial Automation Components
Product Lifecycle:Active
Product description
Square D by Schneider Electric BGA261251 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGA sub-range, featuring a PowerPact B-Frame 125 TMD 2P 125A design for 600Y/347Vac with an 18kA I-line AB 80% rating. It has an I-line connection for AB phases and offers a degree of protection rated at IP40. The rated current is 125A, with a rated voltage for AC at 600Vac 600Y/347Vac. This MCCB has a mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism. It is a 2-pole (2P) device with dimensions of 137 mm in height, 89 mm in depth, and 54 mm in width. The utilisation category is A, and it features over-current protection fixed at 125A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage for DC is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 125 AT. Its electrical durability with load is 10,000 operations at 440Vac; In, and it has a frame current rating of 125 AF. The operating mode is toggle (manual), and it has a short circuit breaking rating of 65kA at 240Vac, 35kA at 480Vac, 35kA at 480Y/277Vac, 18kA at 600Y/347Vac, and 20kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.
Product Details
- Product Or Component Type Circuit breaker
- Control Type Toggle
- Electrical Durability 10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
- [Ue] Rated Operational Voltage 525 V AC 50/60 Hz UL 489
- Range PowerPact
- Suitability For Isolation Yes IEC 60947-2
- Power Wire Stripping Length 0.79 in (20 mm)
- Phase Connection AB
- Local Signalling for presence of auxiliary contacts flag (green)
- Color Grey (RAL 7016)
- Number Of Poles 2P
- Trip Unit Technology Thermal-magnetic
- Device Application Distribution
- Continuous Current Rating 80 %
- Height 5.39 in (137 mm)
- AWG Gauge AWG 14...AWG 2/0 aluminium/copper
- Width 2.13 in (54 mm)
- Device Short Name BG 125
- [Ui] Rated Insulation Voltage 800 V IEC 60947-2
- Line Rated Current 125 A
- [Uimp] Rated Impulse Withstand Voltage 8 kV IEC 60947-2
- Connection Pitch 1.06 in (27 mm)
- Depth 3.50 in (89 mm)
- Product Name PowerPact B
- Breaking Capacity Code G
- Utilisation Category Category A
- Mounting Height 3.00 in (76.2 mm)
- Net Weight 2.10 lb(US) (0.952 kg)
- Mechanical Durability 20000 cycles IEC 947-1 Annex K ed 5.2
- Mounting Mode I-Line
- 9 Mm Pitches 6
- Quantity Per Set Set of 1
- Electrical Connection I-Line connection line Lugs load
- Number Of Slots 1 auxiliary switch OF plug-in) 1 voltage release MN or MX plug-in)
- Tightening Torque 31.86…38.94 lbf.in (3.6…4.4 N.m) 0.00…0.01 in² (2.5…6 mm²) (AWG 14...AWG 10) 44.25…54.87 lbf.in (5…6.2 N.m) 0.02…0.11 in² (10…70 mm²) (AWG 8...AWG 2/0)
- [Ics] Rated Service Breaking Capacity 65 kA 220...240 V AC 50/60 Hz IEC 60947-2 18 kA 500...525 V AC 50/60 Hz IEC 60947-2 35 kA 380...415 V AC 50/60 Hz IEC 60947-2 35 kA 440 V AC 50/60 Hz IEC 60947-2
- Breaking Capacity 65 kA 208Y/120 V AC 50/60 Hz UL 489 65 kA 240 V AC 50/60 Hz UL 489 35 kA 480/277 V AC 50/60 Hz UL 489 35 kA 480 V AC 50/60 Hz UL 489 20 kA 250 V DC UL 489 18 kA 600Y/347 V AC 50/60 Hz UL 489
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of BGA261251 on Powermatic Associates is $2,105.00. Order now.
BGA261251 Related Documents
Similar products from: Schneider Electric Industrial Automation Components
Manufacturer warranty
BGA261251 Schneider Electric
$2,105.00
Your price can be lower.
Log in or Create account to check your discount
Select Qty:
$2,105.00
$2,105.00 each
Average response time: 11 minutes
Worldwide Shipping and Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare BGA261251 with other Industrial Automation Components products
Product Or Component Type
Control Type
Electrical Durability
[Ue] Rated Operational Vo...
Range
Suitability For Isolation
Power Wire Stripping Leng...
Phase Connection
Local Signalling
Color
Selected product

BGA261251
Schneider Electric
Square D by Schneider Electric BGA261251 is a Moulded Case Circuit Breaker (MCCB) within the PowerPa...
Product Or Component TypeCircuit breaker
Control TypeToggle
Electrical Durability10000 cycles IEC 947-1 Annex...
[Ue] Rated Operational Voltage525 V AC 50/60 Hz UL 489
RangePowerPact
Suitability For IsolationYes IEC 60947-2
Power Wire Stripping Length0.79 in (20 mm)
Phase ConnectionAB
Local Signallingfor presence of auxiliary co...
ColorGrey (RAL 7016)
About the manufacturer
Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...
Recently viewed products
Relevant products
FAQ
What is the price of BGA261251?
Purchase the BGA261251 from Powermatic Associates at the price of $2,105.00. Order today.
Out if stock but available for backorder.
Square D by Schneider Electric BGA261251 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGA sub-range, featuring a PowerPact B-Frame 125 TMD 2P 125A design for 600Y/347Vac with an 18kA I-line AB 80% rating. It has an I-line connection for AB phases and offers a degree of protection rated at IP40. The rated current is 125A, with a rated voltage for AC at 600Vac 600Y/347Vac. This MCCB has a mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism. It is a 2-pole (2P) device with dimensions of 137 mm in height, 89 mm in depth, and 54 mm in width. The utilisation category is A, and it features over-current protection fixed at 125A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage for DC is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 125 AT. Its electrical durability with load is 10,000 operations at 440Vac; In, and it has a frame current rating of 125 AF. The operating mode is toggle (manual), and it has a short circuit breaking rating of 65kA at 240Vac, 35kA at 480Vac, 35kA at 480Y/277Vac, 18kA at 600Y/347Vac, and 20kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.
Similar products from: Industrial Automation Components
What can I help you find today?