Product description
Schneider Electric LC1D25V7 is a magnetic contactor from the Deca sub-range, featuring screw connections and designed with 3 poles (3P; 3NO). It has a rated current of 40A (AC-1) and 25A (440Vac; AC-3), with a mounting mode suitable for DIN rail installation. The net width of the contactor is 45 mm, and it offers a degree of protection rated at IP20. The control voltage (AC) ranges from 320-440Vac (400Vac nominal; 50Hz; 0.8...1.1 x Uc) to 340-440Vac (400Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, with a contacts type of 1NO+1NC instantaneous aux. The rated impulse voltage (Uimp) is 6 kV, and the rated active power (kW) spans from 5.5kW at 220-230Vac (AC-3) up to 15kW at 660-690Vac (AC-3). The rated power (HP) varies from 2HP at 115Vac (single-phase; 50Hz/60Hz; UL/CSA) to 20HP at 575-600Vac (3-phase; 50Hz/60Hz; UL/CSA). This contactor is designed for mechanical durability of 15,000,000 operations and electrical durability of 1,600,000 operations with load, supporting a phase-to-phase rated voltage (AC) of 690 V.
Product Details
- Poles Description 3P
- Product Or Component Type Contactor
- Device Short Name LC1D
- Overvoltage Category III
- Insulation Resistance > 10 MOhm signalling circuit
- Product Name TeSys D
- Auxiliary Contact Composition 1 NO + 1 NC
- Rated Breaking Capacity 450 A 440 V power circuit IEC 60947
- Front Cover With
- Mechanical Durability 15 Mcycles
- Power Pole Contact Composition 3 NO
- [Uc] Control Circuit Voltage 400 V AC 50/60 Hz
- Maximum Operating Rate 3600 cyc/h 140 °F (60 °C)
- Minimum Switching Current 5 mA signalling circuit
- Control Circuit Type AC 50/60 Hz
- Heat Dissipation 2…3 W 50/60 Hz
- [Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947
- Minimum Switching Voltage 17 V signalling circuit
- Coil Technology Without built-in suppressor module
- Signalling Circuit Frequency 25...400 Hz
- Range TeSys
- Average Impedance 2 mOhm - Ith 40 A 50 Hz power circuit
- Mounting Support Plate Rail
- Inrush Power In VA 70 VA 60 Hz 0.75 68 °F (20 °C)) 70 VA 50 Hz 0.75 68 °F (20 °C))
- [Ie] Rated Operational Current 25 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit 40 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
- [Ith] Conventional Free Air Thermal Current 10 A 140 °F (60 °C) signalling circuit 40 A 140 °F (60 °C) power circuit
- Power Dissipation Per Pole 3.2 W AC-1 1.25 W AC-3
- [Ue] Rated Operational Voltage Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
- Hold-In Power Consumption In VA 7.5 VA 60 Hz 0.3 68 °F (20 °C)) 7 VA 50 Hz 0.3 68 °F (20 °C))
- Electrical Durability 1.65 Mcycles 25 A AC-3 <= 440 V 1.4 Mcycles 40 A AC-1 <= 440 V
- Contactor Application Resistive load Motor control
- Operating Time 12...22 ms closing 4...19 ms opening
- Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
- Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
- Utilisation Category AC-3 AC-4 AC-1
- Connections - Terminals Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)fl
- Irms Rated Making Capacity 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 450 A 440 V power circuit IEC 60947
- Associated Fuse Rating 10 A gG signalling circuit IEC 60947-5-1 63 A gG <= 690 V type 1 power circuit 40 A gG <= 690 V type 2 power circuit
- Control Circuit Voltage Limits 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
- Tightening Torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals flat Ø 6 mm Power circuit 22.13 lb
- [Ui] Rated Insulation Voltage Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
- Motor Power HP (UL / CSA) 3 hp 230/240 V at AC 50/60 Hz for 1 phase 2 hp 115 V at AC 50/60 Hz for 1 phase 7.5 hp 230/240 V at AC 50/60 Hz for 3 phase 15 hp 460/480 V at AC 50/60 Hz for 3 phase 20 hp 575/600 V at AC 50/60 Hz for 3 phase 7.5 hp 200/208 V at
- Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
- [Icw] Rated Short-Time Withstand Current 240 A 104 °F (40 °C) - 10 s power circuit 380 A 104 °F (40 °C) - 1 s power circuit 50 A 104 °F (40 °C) - 10 min power circuit 120 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circ
- Motor Power Kw 5.5 kW 220...230 V AC 50/60 Hz AC-3) 11 kW 380...400 V AC 50/60 Hz AC-3) 11 kW 415...440 V AC 50/60 Hz AC-3) 15 kW 500 V AC 50/60 Hz AC-3) 15 kW 660...690 V AC 50/60 Hz AC-3) 5.5 kW 400 V AC 50/60 Hz AC-4)
- Product Certifications GOST CCC RINA CSA GL LROS (Lloyds register of shipping) UL DNV BV
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LC1D25V7 on Powermatic Associates is $187.94. Order now.
LC1D25V7 Related Documents
Similar products from: Schneider Electric Industrial Automation Components
Manufacturer warranty
LC1D25V7 Schneider Electric
$187.94
Your price can be lower.
Log in or Create account to check your discount
Select Qty:
$187.94
$187.94 each
Average response time: 11 minutes
Worldwide Shipping and Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare LC1D25V7 with other Industrial Automation Components products
Poles Description
Product Or Component Type
Device Short Name
Overvoltage Category
Insulation Resistance
Product Name
Auxiliary Contact Composi...
Rated Breaking Capacity
Front Cover
Mechanical Durability
Selected product

LC1D25V7
Schneider Electric
Schneider Electric LC1D25V7 is a magnetic contactor from the Deca sub-range, featuring screw connect...
Poles Description3P
Product Or Component TypeContactor
Device Short NameLC1D
Overvoltage CategoryIII
Insulation Resistance> 10 MOhm signalling circuit
Product NameTeSys D
Auxiliary Contact Composition1 NO + 1 NC
Rated Breaking Capacity450 A 440 V power circuit IE...
Front CoverWith
Mechanical Durability15 Mcycles
About the manufacturer
Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...
Recently viewed products
Relevant products
FAQ
What is the price of LC1D25V7?
Purchase the LC1D25V7 from Powermatic Associates at the price of $187.94. Order today.
Out if stock but available for backorder.
Schneider Electric LC1D25V7 is a magnetic contactor from the Deca sub-range, featuring screw connections and designed with 3 poles (3P; 3NO). It has a rated current of 40A (AC-1) and 25A (440Vac; AC-3), with a mounting mode suitable for DIN rail installation. The net width of the contactor is 45 mm, and it offers a degree of protection rated at IP20. The control voltage (AC) ranges from 320-440Vac (400Vac nominal; 50Hz; 0.8...1.1 x Uc) to 340-440Vac (400Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, with a contacts type of 1NO+1NC instantaneous aux. The rated impulse voltage (Uimp) is 6 kV, and the rated active power (kW) spans from 5.5kW at 220-230Vac (AC-3) up to 15kW at 660-690Vac (AC-3). The rated power (HP) varies from 2HP at 115Vac (single-phase; 50Hz/60Hz; UL/CSA) to 20HP at 575-600Vac (3-phase; 50Hz/60Hz; UL/CSA). This contactor is designed for mechanical durability of 15,000,000 operations and electrical durability of 1,600,000 operations with load, supporting a phase-to-phase rated voltage (AC) of 690 V.
Similar products from: Industrial Automation Components