Schneider Electric LC1D40A6M7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and ring-lugs connections. This 3-pole (3P; 3NO) contactor has a rated current of 60A for AC-1 and 40A for 440Vac in AC-3 conditions. It is designed for DIN rail mounting and has a net width of 55 mm. The degree of protection provided is IP20. The control voltage (AC) ranges from 176-242Vac at 50Hz and 187-242Vac at 60Hz, with a nominal voltage of 220Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. Its rated active power reaches up to 30kW for 660-690Vac in AC-3 conditions, and it also features 1 normally closed (NC) auxiliary contact with a contacts type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 30HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of this contactor is up to 6,000,000 operations, and its electrical durability with load is 1,500,000 operations. The rated voltage (AC) phase-to-phase is 690 V.

Product Details

  • Power Pole Contact Composition
    3 NO
  • Auxiliary Contact Composition
    1 NO + 1 NC
  • Rated Breaking Capacity
    800 A 440 V power circuit IEC 60947
  • Heat Dissipation
    4…5 W 50/60 Hz
  • [Uc] Control Circuit Voltage
    220 V AC 50/60 Hz
  • Front Cover
    With
  • Minimum Switching Current
    5 mA signalling circuit
  • Product Name
    TeSys D
  • Average Impedance
    1.5 mOhm - Ith 60 A 50 Hz power circuit
  • Mechanical Durability
    6 Mcycles
  • Minimum Switching Voltage
    17 V signalling circuit
  • [Uimp] Rated Impulse Withstand Voltage
    6 kV IEC 60947
  • Insulation Resistance
    > 10 MOhm signalling circuit
  • Range
    TeSys
  • Control Circuit Type
    AC 50/60 Hz
  • Coil Technology
    Without built-in suppressor module
  • Device Short Name
    LC1D
  • Maximum Operating Rate
    3600 cyc/h 140 °F (60 °C)
  • Poles Description
    3P
  • Product Or Component Type
    Contactor
  • Overvoltage Category
    III
  • Signalling Circuit Frequency
    25...400 Hz
  • Mounting Support
    Plate Rail
  • Power Dissipation Per Pole
    2.4 W AC-3 5.4 W AC-1
  • [Ue] Rated Operational Voltage
    Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
  • [Ie] Rated Operational Current
    60 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit 40 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
  • Contactor Application
    Resistive load Motor control
  • Hold-In Power Consumption In VA
    13 VA 60 Hz 0.3 68 °F (20 °C)) 15 VA 50 Hz 0.3 68 °F (20 °C))
  • [Ith] Conventional Free Air Thermal Current
    10 A 140 °F (60 °C) signalling circuit 60 A 140 °F (60 °C) power circuit
  • Safety Reliability Level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Inrush Power In VA
    140 VA 60 Hz 0.75 68 °F (20 °C)) 160 VA 50 Hz 0.75 68 °F (20 °C))
  • Auxiliary Contacts Type
    Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
  • Operating Time
    4...19 ms opening 12...26 ms closing
  • Non-Overlap Time
    1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
  • Connections - Terminals
    Control circuit lugs-ring terminals 0.31 in (8 mm)) Power circuit lugs-ring terminals 0.65 in (16.5 mm))
  • Electrical Durability
    1.4 Mcycles 60 A AC-1 <= 440 V 1.5 Mcycles 40 A AC-3 <= 440 V
  • Utilisation Category
    AC-1 AC-3 AC-4
  • Associated Fuse Rating
    10 A gG signalling circuit IEC 60947-5-1 80 A gG <= 690 V type 1 power circuit 80 A gG <= 690 V type 2 power circuit
  • Irms Rated Making Capacity
    140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 800 A 440 V power circuit IEC 60947
  • Tightening Torque
    Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 53.10 lbf.in (6 N.m) lugs-ring terminals hexagonal 0.39 in (10 mm) M6
  • Control Circuit Voltage Limits
    0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
  • Product Certifications
    CSA UL GOST CCC
  • [Ui] Rated Insulation Voltage
    Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 690 V IEC 60947-4-1
  • Standards
    CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
  • Motor Power HP (UL / CSA)
    5 hp 230/240 V at AC 50/60 Hz for 1 phase 10 hp 230/240 V at AC 50/60 Hz for 3 phase 30 hp 575/600 V at AC 50/60 Hz for 3 phase 10 hp 200/208 V at AC 50/60 Hz for 3 phase 3 hp 115 V at AC 50/60 Hz for 1 phase 30 hp 460/480 V at AC
  • Motor Power Kw
    18.5 kW 380...400 V AC 50/60 Hz AC-3) 11 kW 220...230 V AC 50/60 Hz AC-3) 22 kW 415...440 V AC 50/60 Hz AC-3) 22 kW 500 V AC 50/60 Hz AC-3) 30 kW 660...690 V AC 50/60 Hz AC-3) 9 kW 400 V AC 50/60 Hz AC-4)
  • [Icw] Rated Short-Time Withstand Current
    320 A 104 °F (40 °C) - 10 s power circuit 720 A 104 °F (40 °C) - 1 s power circuit 72 A 104 °F (40 °C) - 10 min power circuit 165 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circ

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LC1D40A6M7 on Powermatic Associates is $292.93. Order now.



Similar products from: Schneider Electric Industrial Automation Components

Manufacturer warranty

LC1D40A6M7 Schneider Electric

$292.93

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$292.93

$292.93 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare LC1D40A6M7 with other Industrial Automation Components products

Power Pole Contact Compos...

Auxiliary Contact Composi...

Rated Breaking Capacity

Heat Dissipation

[Uc] Control Circuit Volt...

Front Cover

Minimum Switching Current

Product Name

Average Impedance

Mechanical Durability

Selected product

LC1D40A6M7
Backordered
LC1D40A6M7
Schneider Electric

Schneider Electric LC1D40A6M7 is a magnetic contactor from the Deca sub-range, featuring an EverLink...

Power Pole Contact Composition3 NO

Auxiliary Contact Composition1 NO + 1 NC

Rated Breaking Capacity800 A 440 V power circuit IE...

Heat Dissipation4…5 W 50/60 Hz

[Uc] Control Circuit Voltage220 V AC 50/60 Hz

Front CoverWith

Minimum Switching Current5 mA signalling circuit

Product NameTeSys D

Average Impedance1.5 mOhm - Ith 60 A 50 Hz po...

Mechanical Durability6 Mcycles

LC1D40ABD
2 in stock
LC1D40ABD
Schneider Electric

Schneider Electric LC1D40ABD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM)...

Power Pole Contact Composition3 NO

Auxiliary Contact Composition-

Rated Breaking Capacity-

Heat Dissipation-

[Uc] Control Circuit Voltage24 V DC

Front Cover-

Minimum Switching Current-

Product NameTeSys D

Average Impedance-

Mechanical Durability-

DFCC2
14 in stock
DFCC2
Schneider Electric

Schneider Electric - DFCC2

Power Pole Contact Composition-

Auxiliary Contact Composition-

Rated Breaking Capacity-

Heat Dissipation-

[Uc] Control Circuit Voltage-

Front Cover-

Minimum Switching Current-

Product NameTeSys DF

Average Impedance-

Mechanical Durability-

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

Recently viewed products

Relevant products

FAQ

What is the price of LC1D40A6M7?
Purchase the LC1D40A6M7 from Powermatic Associates at the price of $292.93. Order today.

Out if stock but available for backorder.

Schneider Electric LC1D40A6M7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and ring-lugs connections. This 3-pole (3P; 3NO) contactor has a rated current of 60A for AC-1 and 40A for 440Vac in AC-3 conditions. It is designed for DIN rail mounting and has a net width of 55 mm. The degree of protection provided is IP20. The control voltage (AC) ranges from 176-242Vac at 50Hz and 187-242Vac at 60Hz, with a nominal voltage of 220Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. Its rated active power reaches up to 30kW for 660-690Vac in AC-3 conditions, and it also features 1 normally closed (NC) auxiliary contact with a contacts type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 30HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of this contactor is up to 6,000,000 operations, and its electrical durability with load is 1,500,000 operations. The rated voltage (AC) phase-to-phase is 690 V.

Similar products from: Industrial Automation Components

What can I help you find today?

Recommended parts

AFP0RC32T on Powermatic Associates

AFP0RC32T

Panasonic

Panasonic AFP0RC32T is a CPU unit within the C32 sub-range, featuring an integrated Programmable Logic Controller (PLC) with transistor outputs. It offers memory backup and self-diagnostic functions. The unit connects via a MIL connector and mini USB, and is designed for DIN rail mounting. It supports the RS-232 communication protocol and can handle up to 128 x I/O points and 3 x expansion units. The memory capacity is 32K steps for programs and 32765 words / 32K words for data, supporting up to 4096 x I/O points. It includes 16 x digital inputs (24Vdc; Sink/Source; with 6 x high-speed 50kHz counters) and 16 x digital outputs (24Vdc; NPN; 200mA transistor; with 4 x 50kHz Pulse outputs/axes + 4 x 4.8kHz; 1000 resolution PWM channels). There are also 6 x analog inputs (RTD Pt100 / RTD Pt1000 / RTD Ni1000 / Resistance; with 0.1K/°F / 0.01K/°F resolution). Programming is supported in Ladder diagram (LD), Structured text (ST), Function block diagram (FBD), Sequential function chart (SFC), and Instruction list (IL). It features an 8-character password setting for program upload protection. Processing times are 80ns/step for basic instructions up to 3000 steps, with a minimum of 2.2µs, and 320ns/step for high-level instructions up to 3000 steps, with a minimum of 580ns/step for basic instructions after 3000 steps. Operating modes include periodical interrupt (0.5ms-1.5s) execution, interrupt program execution, constant scan execution, and program edition during RUN download in RUN mode.

5 in stock