LC1D65AX7 Schneider Electric Industrial Automation Components

LC1D65AX7 on Powermatic Associates
Schneider Electric

Part#:LC1D65AX7

Manufacturer:Schneider Electric

Category:Industrial Automation Components

Product Lifecycle:Active

Product description

Schneider Electric LC1D65AX7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminals and screw connections. It is designed with 3 poles (3P; 3NO) and supports a rated current of 80A (AC-1) and 65A (440Vac; AC-3). This contactor is suitable for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection rated at IP20 and operates with a control voltage (AC) range of 480-660Vac (600Vac nominal; 50Hz; 0.8...1.1 x Uc) and 510-660Vac (600Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. It has a rated active power of up to 37kW across various AC-3 voltage ranges and supports rated power (HP) for motors ranging from 5HP to 50HP under UL/CSA standards for both single-phase and 3-phase connections. The mechanical durability of the LC1D65AX7 is rated at 6,000,000 operations, and its electrical durability with load is 1,400,000 operations. The rated voltage (AC) for phase-to-phase connections is 690 V.

Product Details

  • Standards
    CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
  • [Icw] Rated Short-Time Withstand Current
    520 A 104 °F (40 °C) - 10 s power circuit 900 A 104 °F (40 °C) - 1 s power circuit 110 A 104 °F (40 °C) - 10 min power circuit 260 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling cir
  • [Ui] Rated Insulation Voltage
    Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 690 V IEC 60947-4-1
  • Motor Power HP (UL / CSA)
    40 hp 460/480 V at AC 50/60 Hz for 3 phase 5 hp 115 V at AC 50/60 Hz for 1 phase 10 hp 230/240 V at AC 50/60 Hz for 1 phase 20 hp 200/208 V at AC 50/60 Hz for 3 phase 20 hp 230/240 V at AC 50/60 Hz for 3 phase 50 hp 575/600 V at A
  • Motor Power Kw
    11 kW 400 V AC 50/60 Hz AC-4) 18.5 kW 220...230 V AC 50/60 Hz AC-3) 30 kW 380...400 V AC 50/60 Hz AC-3) 37 kW 500 V AC 50/60 Hz AC-3) 37 kW 660...690 V AC 50/60 Hz AC-3)
  • Product Certifications
    CCC UL GOST CSA
  • Connections - Terminals
    Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)fle
  • Tightening Torque
    Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 70.81 lbf.in (8 N.m) EverLink BTR screw connectors 0.04…0.05 in² (25…35 mm²) hexagon
  • Associated Fuse Rating
    10 A gG signalling circuit IEC 60947-5-1 125 A gG <= 690 V type 1 power circuit 125 A gG <= 690 V type 2 power circuit
  • Irms Rated Making Capacity
    140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 1000 A 440 V power circuit IEC 60947
  • Utilisation Category
    AC-1 AC-4 AC-3
  • [Ie] Rated Operational Current
    80 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit 65 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
  • Electrical Durability
    1.4 Mcycles 80 A AC-1 <= 440 V 1.45 Mcycles 65 A AC-3 <= 440 V
  • Contactor Application
    Resistive load Motor control
  • Safety Reliability Level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • [Ith] Conventional Free Air Thermal Current
    10 A 140 °F (60 °C) signalling circuit 80 A 140 °F (60 °C) power circuit
  • Non-Overlap Time
    1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
  • Auxiliary Contacts Type
    Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
  • Hold-In Power Consumption In VA
    13 VA 60 Hz 0.3 68 °F (20 °C)) 15 VA 50 Hz 0.3 68 °F (20 °C))
  • Inrush Power In VA
    140 VA 60 Hz 0.75 68 °F (20 °C)) 160 VA 50 Hz 0.75 68 °F (20 °C))
  • [Ue] Rated Operational Voltage
    Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
  • Power Dissipation Per Pole
    9.6 W AC-1 6.3 W AC-3
  • Mounting Support
    Plate Rail
  • Operating Time
    4...19 ms opening 12...26 ms closing
  • Insulation Resistance
    > 10 MOhm signalling circuit
  • Minimum Switching Voltage
    17 V signalling circuit
  • Minimum Switching Current
    5 mA signalling circuit
  • Signalling Circuit Frequency
    25...400 Hz
  • Heat Dissipation
    4…5 W 50/60 Hz
  • Control Circuit Voltage Limits
    0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
  • Coil Technology
    Without built-in suppressor module
  • Maximum Operating Rate
    3600 cyc/h 140 °F (60 °C)
  • Mechanical Durability
    6 Mcycles
  • Front Cover
    With
  • Average Impedance
    1.5 mOhm - Ith 80 A 50 Hz power circuit
  • Auxiliary Contact Composition
    1 NO + 1 NC
  • [Uc] Control Circuit Voltage
    600 V AC 50/60 Hz
  • Rated Breaking Capacity
    1000 A 440 V power circuit IEC 60947
  • Overvoltage Category
    III
  • [Uimp] Rated Impulse Withstand Voltage
    6 kV IEC 60947
  • Control Circuit Type
    AC 50/60 Hz
  • Power Pole Contact Composition
    3 NO
  • Poles Description
    3P
  • Device Short Name
    LC1D
  • Product Or Component Type
    Contactor
  • Product Name
    TeSys D
  • Range
    TeSys

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LC1D65AX7 on Powermatic Associates is $369.84. Order now.



Similar products from: Schneider Electric Industrial Automation Components

Manufacturer warranty

LC1D65AX7 Schneider Electric

$369.84

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$369.84

$369.84 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare LC1D65AX7 with other Industrial Automation Components products

Standards

[Icw] Rated Short-Time Wi...

[Ui] Rated Insulation Vol...

Motor Power HP (UL / CSA)

Motor Power Kw

Product Certifications

Connections - Terminals

Tightening Torque

Associated Fuse Rating

Irms Rated Making Capacit...

Selected product

LC1D65AX7
Backordered
LC1D65AX7
Schneider Electric

Schneider Electric LC1D65AX7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM)...

StandardsCSA C22.2 No 14 EN 60947-4-1...

[Icw] Rated Short-Time Withstand Current520 A 104 °F (40 °C) - 10 s ...

[Ui] Rated Insulation VoltagePower circuit 600 V CSA Powe...

Motor Power HP (UL / CSA)40 hp 460/480 V at AC 50/60 ...

Motor Power Kw11 kW 400 V AC 50/60 Hz AC-4...

Product CertificationsCCC UL GOST CSA

Connections - TerminalsControl circuit screw clamp ...

Tightening TorqueControl circuit 15.05 lbf.in...

Associated Fuse Rating10 A gG signalling circuit I...

Irms Rated Making Capacity140 A AC signalling circuit ...

LC1D65AG7
5 in stock
LC1D65AG7
Schneider Electric

Schneider Electric LC1D65AG7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM)...

Standards-

[Icw] Rated Short-Time Withstand Current-

[Ui] Rated Insulation Voltage-

Motor Power HP (UL / CSA)40 hp 460/480 V at AC 50/60 ...

Motor Power Kw11 kW 400 V AC 50/60 Hz AC-4...

Product Certifications-

Connections - Terminals-

Tightening Torque-

Associated Fuse Rating-

Irms Rated Making Capacity-

LC1D95M7
17 in stock
LC1D95M7
Schneider Electric

Schneider Electric LC1D95M7 is a magnetic contactor from the Deca sub-range, featuring screw connect...

Standards-

[Icw] Rated Short-Time Withstand Current-

[Ui] Rated Insulation Voltage-

Motor Power HP (UL / CSA)7.5 hp 115 V at AC 60 Hz for...

Motor Power Kw25 kW 220...230 V AC 50 Hz A...

Product Certifications-

Connections - Terminals-

Tightening Torque-

Associated Fuse Rating-

Irms Rated Making Capacity-

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

Recently viewed products

Relevant products

FAQ

What is the price of LC1D65AX7?
Purchase the LC1D65AX7 from Powermatic Associates at the price of $369.84. Order today.

Out if stock but available for backorder.

Schneider Electric LC1D65AX7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminals and screw connections. It is designed with 3 poles (3P; 3NO) and supports a rated current of 80A (AC-1) and 65A (440Vac; AC-3). This contactor is suitable for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection rated at IP20 and operates with a control voltage (AC) range of 480-660Vac (600Vac nominal; 50Hz; 0.8...1.1 x Uc) and 510-660Vac (600Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. It has a rated active power of up to 37kW across various AC-3 voltage ranges and supports rated power (HP) for motors ranging from 5HP to 50HP under UL/CSA standards for both single-phase and 3-phase connections. The mechanical durability of the LC1D65AX7 is rated at 6,000,000 operations, and its electrical durability with load is 1,400,000 operations. The rated voltage (AC) for phase-to-phase connections is 690 V.

Similar products from: Industrial Automation Components

What can I help you find today?

Recommended parts