Schneider Electric LC1D95E7 is a magnetic contactor from the Deca sub-range, featuring screw connections and designed with 3 poles (3P; 3NO). It has a rated current of 125A for AC-1 and 95A for 440Vac in AC-3 conditions. This contactor is suitable for DIN rail mounting and has a net width of 85 mm. It offers a degree of protection rated at IP20 and operates with a control voltage (AC) range of 38.4-52.8Vac (48Vac nominal; 50Hz; 0.8...1.1 x Uc) and 40.8-52.8Vac (48Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is up to 1000 V, and it includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 8 kV. Its rated active power ranges from 25kW at 220-230Vac to 55kW at 500Vac in AC-3 conditions, and it supports various rated powers in horsepower (HP) for different voltages and phases, including 7.5HP at 115Vac and up to 60HP at 575-600Vac. The mechanical durability of the LC1D95E7 is rated at 4,000,000 operations, and its electrical durability with load is 1,200,000 operations. The rated voltage for phase-to-phase connections is 1000 V.

Product Details

  • Product Certifications
    IECEE CB Scheme UL CSA CCC EAC LROS (Lloyds register of shipping) RINA BV DNV-GL
  • Standards
    EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4
  • [Icw] Rated Short-Time Withstand Current
    1100 A 104 °F (40 °C) - 1 s power circuit 800 A 104 °F (40 °C) - 10 s power circuit 400 A 104 °F (40 °C) - 1 min power circuit 135 A 104 °F (40 °C) - 10 min power circuit 140 A - 100 ms signalling circuit 120 A - 500 ms signalling
  • [Ui] Rated Insulation Voltage
    Power circuit 1000 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
  • Motor Power Kw
    25 kW 220...230 V AC 50 Hz AC-3) 45 kW 380...400 V AC 50 Hz AC-3) 45 kW 415...440 V AC 50 Hz AC-3) 55 kW 500 V AC 50 Hz AC-3) 45 kW 660...690 V AC 50 Hz AC-3) 45 kW 1000 V AC 50 Hz AC-3)
  • Motor Power HP (UL / CSA)
    7.5 hp 115 V at AC 60 Hz for 1 phase 15 hp 230/240 V at AC 60 Hz for 1 phase 25 hp 200/208 V at AC 60 Hz for 3 phase 30 hp 230/240 V at AC 60 Hz for 3 phase 60 hp 460/480 V at AC 60 Hz for 3 phase 60 hp 575/600 V at AC 60 Hz for 3
  • Control Circuit Voltage Limits
    0.8...1.1 Uc -40…131 °F (-40…55 °C) operational AC 50 Hz 0.85...1.1 Uc -40…131 °F (-40…55 °C) operational AC 60 Hz 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 1...1.1 Uc 131…158 °F (55…70 °C) operational AC 50/60 Hz
  • Tightening Torque
    Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.21 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm Power circuit 106.21 lbf.in
  • Connections - Terminals
    Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flex
  • Irms Rated Making Capacity
    1100 A 440 V AC power circuit IEC 60947 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1
  • Utilisation Category
    AC-4 AC-1 AC-3
  • Associated Fuse Rating
    10 A gG signalling circuit IEC 60947-5-1 200 A gG <= 690 V type 1 power circuit 160 A gG <= 690 V type 2 power circuit
  • Auxiliary Contacts Type
    Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
  • Mounting Support
    Rail Plate
  • Operating Time
    20...35 ms closing 6...20 ms opening
  • Hold-In Power Consumption In VA
    26 VA 60 Hz 0.3 68 °F (20 °C)) 26 VA 50 Hz 0.3 68 °F (20 °C))
  • [Ie] Rated Operational Current
    95 A 140 °F (60 °C)) <= 440 V AC-3 power circuit 125 A 140 °F (60 °C)) <= 690 V AC-1 power circuit
  • Inrush Power In VA
    245 VA 60 Hz 0.75 68 °F (20 °C)) 245 VA 50 Hz 0.75 68 °F (20 °C))
  • Power Dissipation Per Pole
    12.5 W AC-1 7.2 W AC-3
  • [Ith] Conventional Free Air Thermal Current
    10 A 140 °F (60 °C) signalling circuit 125 A 140 °F (60 °C) power circuit
  • Safety Reliability Level
    B10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1 B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1
  • Non-Overlap Time
    1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
  • Contactor Application
    Motor control Resistive load
  • Electrical Durability
    1.2 Mcycles 95 A AC-3 1.3 Mcycles 125 A AC-1
  • Insulation Resistance
    > 10 MOhm signalling circuit
  • Minimum Switching Voltage
    17 V signalling circuit
  • Coil Technology
    Without built-in suppressor module
  • Minimum Switching Current
    5 mA signalling circuit
  • Signalling Circuit Frequency
    25...400 Hz
  • Heat Dissipation
    6…10 W 50/60 Hz
  • Mechanical Durability
    4 Mcycles
  • Maximum Operating Rate
    3600 cyc/h 140 °F (60 °C)
  • Front Cover
    With
  • Average Impedance
    0.8 mOhm - Ith 125 A 50 Hz power circuit
  • Rated Breaking Capacity
    1100 A 440 V power circuit IEC 60947
  • [Uimp] Rated Impulse Withstand Voltage
    8 kV IEC 60947
  • [Uc] Control Circuit Voltage
    48 V AC 50/60 Hz
  • Auxiliary Contact Composition
    1 NO + 1 NC
  • Control Circuit Type
    AC 50/60 Hz
  • Overvoltage Category
    III
  • [Ue] Rated Operational Voltage
    Power circuit 1000 V AC 25...400 Hz
  • Power Pole Contact Composition
    3 NO
  • Product Or Component Type
    Contactor
  • Poles Description
    3P
  • Device Short Name
    LC1D
  • Product Name
    TeSys D
  • Range
    TeSys

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LC1D95E7 on Powermatic Associates is $589.15. Order now.



Similar products from: Schneider Electric Industrial Automation Components

Manufacturer warranty

LC1D95E7 Schneider Electric

$589.15

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$589.15

$589.15 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare LC1D95E7 with other Industrial Automation Components products

Product Certifications

Standards

[Icw] Rated Short-Time Wi...

[Ui] Rated Insulation Vol...

Motor Power Kw

Motor Power HP (UL / CSA)

Control Circuit Voltage L...

Tightening Torque

Connections - Terminals

Irms Rated Making Capacit...

Selected product

LC1D95E7
Backordered
LC1D95E7
Schneider Electric

Schneider Electric LC1D95E7 is a magnetic contactor from the Deca sub-range, featuring screw connect...

Product CertificationsIECEE CB Scheme UL CSA CCC E...

StandardsEN/IEC 60947-1 EN/IEC 60947-...

[Icw] Rated Short-Time Withstand Current1100 A 104 °F (40 °C) - 1 s ...

[Ui] Rated Insulation VoltagePower circuit 1000 V IEC 609...

Motor Power Kw25 kW 220...230 V AC 50 Hz A...

Motor Power HP (UL / CSA)7.5 hp 115 V at AC 60 Hz for...

Control Circuit Voltage Limits0.8...1.1 Uc -40…131 °F (-40...

Tightening TorqueControl circuit 10.62 lbf.in...

Connections - TerminalsControl circuit screw clamp ...

Irms Rated Making Capacity1100 A 440 V AC power circui...

LC1D95M7
17 in stock
LC1D95M7
Schneider Electric

Schneider Electric LC1D95M7 is a magnetic contactor from the Deca sub-range, featuring screw connect...

Product Certifications-

Standards-

[Icw] Rated Short-Time Withstand Current-

[Ui] Rated Insulation Voltage-

Motor Power Kw25 kW 220...230 V AC 50 Hz A...

Motor Power HP (UL / CSA)7.5 hp 115 V at AC 60 Hz for...

Control Circuit Voltage Limits-

Tightening Torque-

Connections - Terminals-

Irms Rated Making Capacity-

LC1D956BD
2 in stock
LC1D956BD
Schneider Electric

Schneider Electric LC1D956BD is a magnetic contactor from the Deca sub-range, designed for ring-lugs...

Product Certifications-

Standards-

[Icw] Rated Short-Time Withstand Current-

[Ui] Rated Insulation Voltage-

Motor Power Kw25 kW 220...230 V AC 50 Hz A...

Motor Power HP (UL / CSA)7.5 hp 115 V at AC 60 Hz for...

Control Circuit Voltage Limits-

Tightening Torque-

Connections - Terminals-

Irms Rated Making Capacity-

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

Recently viewed products

Relevant products

FAQ

What is the price of LC1D95E7?
Purchase the LC1D95E7 from Powermatic Associates at the price of $589.15. Order today.

Out if stock but available for backorder.

Schneider Electric LC1D95E7 is a magnetic contactor from the Deca sub-range, featuring screw connections and designed with 3 poles (3P; 3NO). It has a rated current of 125A for AC-1 and 95A for 440Vac in AC-3 conditions. This contactor is suitable for DIN rail mounting and has a net width of 85 mm. It offers a degree of protection rated at IP20 and operates with a control voltage (AC) range of 38.4-52.8Vac (48Vac nominal; 50Hz; 0.8...1.1 x Uc) and 40.8-52.8Vac (48Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is up to 1000 V, and it includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 8 kV. Its rated active power ranges from 25kW at 220-230Vac to 55kW at 500Vac in AC-3 conditions, and it supports various rated powers in horsepower (HP) for different voltages and phases, including 7.5HP at 115Vac and up to 60HP at 575-600Vac. The mechanical durability of the LC1D95E7 is rated at 4,000,000 operations, and its electrical durability with load is 1,200,000 operations. The rated voltage for phase-to-phase connections is 1000 V.