Schneider Electric LC1DT80AN7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections for secure installation. This 4-pole (4P; 4NO) contactor is designed to handle a rated current of 80A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection rated at IP20. The control voltage for AC ranges between 332-456Vac (415Vac nominal; 50Hz; 0.8...1.1 x Uc) and 353-456Vac (415Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with the contacts type being 1NO+1NC instantaneous auxiliaries. The LC1DT80AN7 is designed for mechanical durability up to 6 million operations at no load, and it has a rated impulse voltage (Uimp) of 6 kV. The rated voltage (AC) for phase-to-phase connections is 690 V.
Product Details
- Product Certifications GOST BV CSA LROS (Lloyds register of shipping) CCC UL DNV GL RINA
- Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
- [Ui] Rated Insulation Voltage Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 690 V IEC 60947-4-1
- [Icw] Rated Short-Time Withstand Current 520 A 104 °F (40 °C) - 10 s power circuit 900 A 104 °F (40 °C) - 1 s power circuit 110 A 104 °F (40 °C) - 10 min power circuit 260 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling cir
- Control Circuit Voltage Limits 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
- Connections - Terminals Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)fle
- Associated Fuse Rating 10 A gG signalling circuit IEC 60947-5-1 125 A gG <= 690 V type 1 power circuit 125 A gG <= 690 V type 2 power circuit
- Irms Rated Making Capacity 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 1000 A 440 V power circuit IEC 60947
- Tightening Torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 70.81 lbf.in (8 N.m) screw clamp terminals 0.04…0.05 in² (25…35 mm²) hexagonal 0.16
- Inrush Power In VA 140 VA 60 Hz 0.75 68 °F (20 °C)) 160 VA 50 Hz 0.75 68 °F (20 °C))
- Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Hold-In Power Consumption In VA 13 VA 60 Hz 0.3 68 °F (20 °C)) 15 VA 50 Hz 0.3 68 °F (20 °C))
- Operating Time 4...19 ms opening 12...26 ms closing
- Mounting Support Rail Plate
- [Ith] Conventional Free Air Thermal Current 10 A 140 °F (60 °C) signalling circuit 80 A 140 °F (60 °C) power circuit
- Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
- Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
- [Ue] Rated Operational Voltage Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
- Heat Dissipation 4…5 W 50/60 Hz
- Minimum Switching Current 5 mA signalling circuit
- Insulation Resistance > 10 MOhm for signalling circuit
- Minimum Switching Voltage 17 V signalling circuit
- Signalling Circuit Frequency 25...400 Hz
- Coil Technology Without built-in suppressor module
- Maximum Operating Rate 3600 cyc/h 140 °F (60 °C)
- Mechanical Durability 6 Mcycles
- Front Cover With
- Power Dissipation Per Pole 10.2 W AC-1
- Electrical Durability 1.4 Mcycles 80 A AC-1 <= 440 V
- Average Impedance 1.6 mOhm - Ith 80 A 50 Hz power circuit
- Rated Breaking Capacity 1000 A 440 V power circuit IEC 60947
- [Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947
- Auxiliary Contact Composition 1 NO + 1 NC
- Control Circuit Type AC at 50/60 Hz
- Overvoltage Category III
- [Uc] Control Circuit Voltage 415 V AC 50/60 Hz
- [Ie] Rated Operational Current 80 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
- Range TeSys
- Device Short Name LC1D
- Contactor Application Resistive load
- Utilisation Category AC-1
- Product Or Component Type Contactor
- Poles Description 4P
- Product Name TeSys D
- Power Pole Contact Composition 4 NO
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LC1DT80AN7 on Powermatic Associates is $535.55. Order now.
LC1DT80AN7 Related Documents
Similar products from: Schneider Electric Industrial Automation Components
Manufacturer warranty
LC1DT80AN7 Schneider Electric
$535.55
Your price can be lower.
Log in or Create account to check your discount
Select Qty:
$535.55
$535.55 each
Average response time: 11 minutes
Worldwide Shipping and Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare LC1DT80AN7 with other Industrial Automation Components products
Product Certifications
Standards
[Ui] Rated Insulation Vol...
[Icw] Rated Short-Time Wi...
Control Circuit Voltage L...
Connections - Terminals
Associated Fuse Rating
Irms Rated Making Capacit...
Tightening Torque
Inrush Power In VA
Selected product

LC1DT80AN7
Schneider Electric
Schneider Electric LC1DT80AN7 is a magnetic contactor from the Deca sub-range, featuring an EverLink...
Product CertificationsGOST BV CSA LROS (Lloyds reg...
StandardsCSA C22.2 No 14 EN 60947-4-1...
[Ui] Rated Insulation VoltagePower circuit 600 V CSA Powe...
[Icw] Rated Short-Time Withstand Current520 A 104 °F (40 °C) - 10 s ...
Control Circuit Voltage Limits0.3...0.6 Uc -40…158 °F (-40...
Connections - TerminalsControl circuit screw clamp ...
Associated Fuse Rating10 A gG signalling circuit I...
Irms Rated Making Capacity140 A AC signalling circuit ...
Tightening TorqueControl circuit 15.05 lbf.in...
Inrush Power In VA140 VA 60 Hz 0.75 68 °F (20 ...
About the manufacturer
Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...
Recently viewed products
Relevant products
FAQ
What is the price of LC1DT80AN7?
Purchase the LC1DT80AN7 from Powermatic Associates at the price of $535.55. Order today.
Out if stock but available for backorder.
Schneider Electric LC1DT80AN7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections for secure installation. This 4-pole (4P; 4NO) contactor is designed to handle a rated current of 80A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection rated at IP20. The control voltage for AC ranges between 332-456Vac (415Vac nominal; 50Hz; 0.8...1.1 x Uc) and 353-456Vac (415Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with the contacts type being 1NO+1NC instantaneous auxiliaries. The LC1DT80AN7 is designed for mechanical durability up to 6 million operations at no load, and it has a rated impulse voltage (Uimp) of 6 kV. The rated voltage (AC) for phase-to-phase connections is 690 V.
Similar products from: Industrial Automation Components
What can I help you find today?