LGL36400CU31X Schneider Electric Industrial Automation Components

LGL36400CU31X on Powermatic Associates
Schneider Electric

Part#:LGL36400CU31X

Manufacturer:Schneider Electric

Category:Industrial Automation Components

Product Lifecycle:Active

Product description

Square D by Schneider Electric LGL36400CU31X is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT LGL sub-range, featuring a PowerPact L-Frame 600 Micrologic 3.3 (LI) design. It is a 3-pole (3P) device with a rated current of 400A and offers long-time (L) and instantaneous (I) protection functions. The breaker is designed for individual unit mount on plate with lugs on both load and line sides for connection. It has a rated insulation voltage (Ui) of 750 V, a rated voltage (AC) of 600Vac 600Y/347Vac, and a rated operating voltage (Ue) of 690 V. The device's degree of protection is IP40, and it operates manually via a toggle. Protection settings are adjustable for overload (0.3...1 x In, 125A...400A) and short-circuit (1.5...12 x In, 600A...4800A) conditions. The MCCB has a net height of 382 mm, width of 153 mm, and depth of 171 mm. Its trip current rating is 400 AT, with a frame current rating of 600 AF. The short circuit breaking rating varies by voltage, up to 65kA at 240Vac under UL489 standards. The trip unit type is an electronic Micrologic Standard 3.3 (LI) with no display, and it has a rated impulse voltage (Uimp) of 8 kV. The utilisation category is A.

Product Details

  • Number Of Poles
    3P
  • Product Or Component Type
    Circuit breaker
  • Breaking Capacity Code
    G
  • Height
    11.3 in (287.02 mm)
  • Width
    5.5 in (139.70 mm)
  • Terminal Identifier
    AL600LS52K3
  • Continuous Current Rating
    100 %
  • Depth
    6.61 in (167.89 mm)
  • Tightening Torque
    442.54 lbf.in (50 N.m) 0.11…0.37 in² (70…240 mm²) (AWG 2/0...500 kcmil)
  • Electrical Connection
    Lugs load Lugs line

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LGL36400CU31X on Powermatic Associates is $5,945.00. Order now.



Similar products from: Schneider Electric Industrial Automation Components

Manufacturer warranty

LGL36400CU31X Schneider Electric

$5,945.00

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$5,945.00

$5,945.00 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare LGL36400CU31X with other Industrial Automation Components products

Number Of Poles

Product Or Component Type

Breaking Capacity Code

Height

Width

Terminal Identifier

Continuous Current Rating

Depth

Tightening Torque

Electrical Connection

Selected product

LGL36400CU31X
Backordered
LGL36400CU31X
Schneider Electric

Square D by Schneider Electric LGL36400CU31X is a Moulded Case Circuit Breaker (MCCB) within the Pow...

Number Of Poles3P

Product Or Component TypeCircuit breaker

Breaking Capacity CodeG

Height11.3 in (287.02 mm)

Width5.5 in (139.70 mm)

Terminal IdentifierAL600LS52K3

Continuous Current Rating100 %

Depth6.61 in (167.89 mm)

Tightening Torque442.54 lbf.in (50 N.m) 0.11…...

Electrical ConnectionLugs load Lugs line

LGL36400U31X
1 in stock
LGL36400U31X
Schneider Electric

Square D by Schneider Electric LGL36400U31X is a Moulded Case Circuit Breaker (MCCB) within the Powe...

Number Of Poles3P

Product Or Component TypeCircuit breaker

Breaking Capacity CodeG

Height11.3 in (287.02 mm)

Width5.5 in (139.70 mm)

Terminal IdentifierAL600LS52K3

Continuous Current Rating80 %

Depth6.61 in (167.89 mm)

Tightening Torque442.54 lbf.in (50 N.m) 0.11…...

Electrical ConnectionLugs load Lugs line

HGL36150U33X
2 in stock
HGL36150U33X
Schneider Electric

Square D by Schneider Electric HGL36150U33X is a Moulded Case Circuit Breaker (MCCB) within the Powe...

Number Of Poles3P

Product Or Component TypeCircuit breaker

Breaking Capacity CodeG

Height6.4 in (162.56 mm)

Width4.12 in (104.65 mm)

Terminal Identifier-

Continuous Current Rating80 %

Depth4.36 in (110.74 mm)

Tightening Torque44.25 lbf.in (5 N.m) 0.00…0....

Electrical ConnectionLugs load Lugs line

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

Recently viewed products

Relevant products

LGL36600U53XENAAUOYH1 on Powermatic Associates

LGL36600U53XENAAUOYH1

Verified stock: 2

Square D by Schneider Electric LGL36600U53XENAAUOYH1 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT LGL sub-range. It features a factory-installed 24Vdc undervoltage (U/V) trip release coil and a factory-installed 1A/1B (1NO+1NC) auxiliary switch OF wire harness. Designed for PowerPacT L-Frame, this 3-pole (3P) breaker has a rated current of 600A and operates at a rated voltage of 600Vac and 600Y/347Vac, with a rated insulation voltage (Ui) of 750V. It offers long-time (L), short-time with fixed time delay (S), instantaneous (I), and Zone Selective Interlocking (ZSI) protection functions. The breaker is equipped with lugs on both load and line sides for connection and is designed for individual unit mount on plate. It has a net height of 382mm, width of 153mm, depth of 171mm, and offers a degree of protection of IP40. The operating mode is manual toggle, with protection settings adjustable for overload, short-circuit with time delay, and instantaneous protection against short-circuit. The control voltage for the undervoltage trip coil allows circuit breaker opening at 35% to 70% of its rated control voltage, with closing permitted when the supply voltage reaches 85% of rated control voltage. The rated operating voltage (Ue) is 690V, with a rated impulse voltage (Uimp) of 8kV. The trip current rating is 600 AT, with a frame current rating of 600 AF. It has a short circuit breaking rating of up to 65kA at 240Vac under UL489 standards. The trip unit type is an electronic Micrologic Energy 5.3E (LSI) with an LCD display, offering comprehensive measurement functions for current, voltage, power, energy metering, power quality, and harmonic analysis. The utilisation category is A.

Schneider Electric

LGL36400CU44X on Powermatic Associates

LGL36400CU44X

Verified stock: 0

Square D by Schneider Electric LGL36400CU44X is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT LGL sub-range, designed as a PowerPact L-Frame 600 Micrologic 6.3A (LSIG) 3P 400A 600Vac 18kA with lugs 100% rated for connections on both load and line sides. It features three poles (3P) and offers protection functions including Long-time (L), Short-time with fixed time delay (S), Instantaneous (I), Ground fault (G), and Zone Selective Interlocking (ZSI). The rated current is 400A, with a rated insulation voltage (Ui) of 750 V, and a rated voltage (AC) of 600Vac 600Y/347Vac. It is designed for individual unit mount on plate, with dimensions of 382 mm in height, 153 mm in width, and 171 mm in depth, and has an IP40 degree of protection. The operating mode is manual toggle, with protection settings adjustable for overload (L), short-circuit with time delay (S), instantaneous protection against short-circuit (I), and earth fault (G). The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 400 AT, with a frame current rating of 600 AF, and a short circuit breaking rating varying from 65kA at 240Vac to 20kA at 500Vdc, according to UL489 standards. The trip unit type features electronic technology with a Micrologic 6.3A (LSIG) series, providing LSIG protection and an LCD display. Its measurement function includes current measurements for phases and neutral, RMS instantaneous current, current unbalance between phases, highest RMS current of the 3 phases, ground fault current, and demand/peak current values on all 3 phases plus neutral, with a calculation window adjustable between 5-60 minutes. The utilisation category is A.

Schneider Electric

FAQ

What is the price of LGL36400CU31X?
Purchase the LGL36400CU31X from Powermatic Associates at the price of $5,945.00. Order today.

Out if stock but available for backorder.

Square D by Schneider Electric LGL36400CU31X is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT LGL sub-range, featuring a PowerPact L-Frame 600 Micrologic 3.3 (LI) design. It is a 3-pole (3P) device with a rated current of 400A and offers long-time (L) and instantaneous (I) protection functions. The breaker is designed for individual unit mount on plate with lugs on both load and line sides for connection. It has a rated insulation voltage (Ui) of 750 V, a rated voltage (AC) of 600Vac 600Y/347Vac, and a rated operating voltage (Ue) of 690 V. The device's degree of protection is IP40, and it operates manually via a toggle. Protection settings are adjustable for overload (0.3...1 x In, 125A...400A) and short-circuit (1.5...12 x In, 600A...4800A) conditions. The MCCB has a net height of 382 mm, width of 153 mm, and depth of 171 mm. Its trip current rating is 400 AT, with a frame current rating of 600 AF. The short circuit breaking rating varies by voltage, up to 65kA at 240Vac under UL489 standards. The trip unit type is an electronic Micrologic Standard 3.3 (LI) with no display, and it has a rated impulse voltage (Uimp) of 8 kV. The utilisation category is A.

Similar products from: Industrial Automation Components

What can I help you find today?

Recommended parts