PILZ-890150 Pilz Voltage Relays

PILZ-890150 on Powermatic Associates
Pilz

Part#:PILZ-890150

Manufacturer:Pilz

Category:Voltage Relays

Product Lifecycle:Active

Product description

Pilz PILZ-890150 is a protection unit designed for true power monitoring with a relay that supports 9 different measuring ranges. It features adjustable switching for underload and overload thresholds, along with customizable monitoring reaction time and start-up suppression time. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and is rated for an 18A measuring current. The safety output contacts ratings vary from 0.1A to 5A at 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), to 0.1A-1.5A at 24Vdc (DC-13) and 0.1A-1.8A at 230Vac (AC-15). Connection is established via fixed screw terminal connections. The supply voltage can range from 27.5-264.5Vac for AC and 93.5-287.5Vdc for DC, covering nominal voltages of 110Vac/120Vac/220Vac/230Vac and 110Vdc/120Vdc/220Vdc/250Vdc respectively. The S1WP sub-range model has dimensions of W22.5mm, with a degree of protection rated at IP40. It can handle a frequency measuring range of 0-1kHz and is constructed with a PPO housing. This unit is designed for both single-phase (1AC) and 3-phase (3AC) input networks, with a rated voltage for AC measuring voltage up to 415Vac/dc. The net width and depth are 22.5 mm and 121 mm, respectively, with a power consumption of 5 VA. It is capable of storage in ambient air temperatures ranging from -40 to +85°C. The digital outputs include 1 x auxiliary output (SPDT-NO/NC contacts) suitable for resistive loads, and it features 1 x analog input for current measurement and 1 x analog input for voltage measurement. The protection functions include underpower and overpower monitoring, complemented by 1 x analog output for voltage and current monitoring.

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Manufacturer warranty

PILZ-890150 Pilz

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

About the manufacturer

Pilz

Powermatic Associates is an authorized Pilz distributor, committed to bringing you the highest standards in industrial automation and safety technology. Pilz is a renowned manufacturer specializing in innovative solutions for safe automation. Their expertise lies in developing products that secure your machinery and processes, ensuring high productivity while safeguarding both human workers and eq...

Recently viewed products

BGA34060Y on Powermatic Associates

BGA34060Y

Schneider Electric

Square D by Schneider Electric BGA34060Y is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGA sub-range, featuring a PowerPact B-Frame 100 TMD 3P 60A 480Y/277Vac 35kA I-line design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection for ABC phases. With a degree of protection rated at IP40, this MCCB has a rated current of 60A and supports a rated voltage (AC) of 480Vac and 480Y/277Vac. It is designed for mechanical durability of 20,000 operations at no load and offers a mounting mode that mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism for robust attachment. The unit features 3 poles (3P), with dimensions of 137 mm in height, 89 mm in depth, and 81 mm in width. It falls under utilisation category A and offers protection settings including over-current fixed at 60A, short-circuit hold current fixed at 640A, and short-circuit trip current fixed at 960A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 60 AT. Its electrical durability with load is rated for 10,000 operations at 440Vac; In, and it has a frame current rating of 100 AF. The operating mode is toggle (manual), and it has a short circuit breaking rating of 65kA at 240Vac, 35kA at 480Vac, 35kA at 480Y/277Vac, 14kA at 600Y/347Vac, and 20kA at 250Vdc, all in accordance with UL489. The trip unit type is thermal-magnetic (fixed) with no display.

0 in stock

FAQ

Out if stock but available for backorder.

Pilz PILZ-890150 is a protection unit designed for true power monitoring with a relay that supports 9 different measuring ranges. It features adjustable switching for underload and overload thresholds, along with customizable monitoring reaction time and start-up suppression time. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and is rated for an 18A measuring current. The safety output contacts ratings vary from 0.1A to 5A at 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), to 0.1A-1.5A at 24Vdc (DC-13) and 0.1A-1.8A at 230Vac (AC-15). Connection is established via fixed screw terminal connections. The supply voltage can range from 27.5-264.5Vac for AC and 93.5-287.5Vdc for DC, covering nominal voltages of 110Vac/120Vac/220Vac/230Vac and 110Vdc/120Vdc/220Vdc/250Vdc respectively. The S1WP sub-range model has dimensions of W22.5mm, with a degree of protection rated at IP40. It can handle a frequency measuring range of 0-1kHz and is constructed with a PPO housing. This unit is designed for both single-phase (1AC) and 3-phase (3AC) input networks, with a rated voltage for AC measuring voltage up to 415Vac/dc. The net width and depth are 22.5 mm and 121 mm, respectively, with a power consumption of 5 VA. It is capable of storage in ambient air temperatures ranging from -40 to +85°C. The digital outputs include 1 x auxiliary output (SPDT-NO/NC contacts) suitable for resistive loads, and it features 1 x analog input for current measurement and 1 x analog input for voltage measurement. The protection functions include underpower and overpower monitoring, complemented by 1 x analog output for voltage and current monitoring.

What can I help you find today?

Recommended parts