BJA161251 Schneider Electric Molded Case Circuit Breakers (MCCB)

BJA161251 on Powermatic Associates
Schneider Electric

Part#:BJA161251

Manufacturer:Schneider Electric

Category:Molded Case Circuit Breakers (MCCB)

Product Lifecycle:Active

Product description

Square D by Schneider Electric BJA161251 is a moulded case circuit breaker (MCCB) within the PowerPacT BJA sub-range. It features a PowerPact B-Frame 125 TMD 1P 125A 600Y/347Vac 25kA I-line design with an I-line connection (A phase) and is rated for an impulse voltage of 8 kV. This MCCB has an IP40 degree of protection and supports a rated current of 125A with a rated voltage of 600Vac 600Y/347Vac. It offers mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism for robust attachment. The unit is a 1-pole (1P) device with dimensions of 137 mm in height, 89 mm in depth, and 27 mm in width. It falls under utilisation category A and features over-current protection fixed at 125A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage for DC applications is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. Protection functions include thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 125 AT. Its electrical durability with load is rated for 10,000 operations at 240Vac; In, and it has a frame current rating of 125 AF. The operating mode is manual toggle, and it has a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display.

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Manufacturer warranty

BJA161251 Schneider Electric

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

About the Product Category

An MCCB, or Molded Case Circuit Breaker, is an electrical safety device that automatically disconnects electrical power when it identifies an overload, short circuit, or ground fault. Its purpose is to safeguard an electrical circuit from harm due to excessive current caused by an overload or short circuit.

Molded Case Circuit Breakers (MCCB)

Recently viewed products

Relevant products

BJA160351 on Powermatic Associates

BJA160351

Verified stock: 0

Square D by Schneider Electric BJA160351 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJA sub-range, featuring a PowerPact B-Frame 100 TMD 1P 35A 600Y/347Vac 25kA I-line A 80% rated design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection (A phase) with a degree of protection rated at IP40. The rated current is 35A, with a rated voltage (AC) of 600Vac 600Y/347Vac. This MCCB offers mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism for robust attachment. It is a 1-pole (1P) device with dimensions of 137 mm in height, 89 mm in depth, and 27 mm in width. The utilisation category is A, and it features over-current protection fixed at 35A, short-circuit hold current protection fixed at 400A, and short-circuit trip current protection fixed at 600A. The rated voltage (DC) is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 35 AT. Its electrical durability with load is 10,000 operations at 240Vac; In, and it has a frame current rating of 100 AF. The operating mode is toggle (manual), and it has a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

BJA160501 on Powermatic Associates

BJA160501

Verified stock: 0

Square D by Schneider Electric BJA160501 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJA sub-range, featuring a PowerPact B-Frame 100 TMD 1P 50A 600Y/347Vac 25kA I-line A 80% rated design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection (A phase) with a degree of protection rated at IP40. The rated current is 50A, with a rated voltage (AC) of 600Vac 600Y/347Vac. This MCCB is designed for mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism for robust attachment. It is a 1-pole (1P) device with dimensions of 137 mm in height, 89 mm in depth, and 27 mm in width. The utilisation category is A, and it offers protection settings including over-current fixed at 50A, short-circuit hold current fixed at 480A, and short-circuit trip current fixed at 720A. The rated voltage (DC) is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 50 AT. Its electrical durability with load is 10,000 operations at 240Vac; In, and it has a frame current rating of 100 AF. The operating mode is toggle (manual), and it has a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

FAQ

Out if stock but available for backorder.

Square D by Schneider Electric BJA161251 is a moulded case circuit breaker (MCCB) within the PowerPacT BJA sub-range. It features a PowerPact B-Frame 125 TMD 1P 125A 600Y/347Vac 25kA I-line design with an I-line connection (A phase) and is rated for an impulse voltage of 8 kV. This MCCB has an IP40 degree of protection and supports a rated current of 125A with a rated voltage of 600Vac 600Y/347Vac. It offers mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism for robust attachment. The unit is a 1-pole (1P) device with dimensions of 137 mm in height, 89 mm in depth, and 27 mm in width. It falls under utilisation category A and features over-current protection fixed at 125A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage for DC applications is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. Protection functions include thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 125 AT. Its electrical durability with load is rated for 10,000 operations at 240Vac; In, and it has a frame current rating of 125 AF. The operating mode is manual toggle, and it has a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display.

What can I help you find today?

Recommended parts