BJL16060 Schneider Electric Industrial Automation Components

BJL16060 on Powermatic Associates
Schneider Electric

Part#:BJL16060

Manufacturer:Schneider Electric

Category:Industrial Automation Components

Product Lifecycle:Active

Product description

Square D by Schneider Electric BJL16060 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJL sub-range, featuring a PowerPact B-Frame 100 TMD 1P-1t 60A 600Y/347Vac 25kA design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes Everlink (Creep compensating) lugs for connections on both line and load sides, offering a degree of protection of IP40. The rated current is 60A, with a rated voltage (AC) of 600Vac 600Y/347Vac. It is designed for mechanical durability of 15,000 operations at no load and can be mounted on a DIN rail or individually on a plate. This 1-pole (1P) circuit breaker has dimensions of 137 mm in height, 80 mm in depth, and 27 mm in width. It falls under utilisation category A and features protection settings for over-current fixed at 60A, short-circuit hold current fixed at 640A, and short-circuit trip current fixed at 960A. The rated voltage (DC) is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. Its protection functions include thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 60 AT. The electrical durability with load is rated for 10,000 operations at 240Vac; In, and it has a frame current rating of 100 AF. The operating mode is manual toggle, and it has a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all in accordance with UL489. The trip unit type is thermal-magnetic (fixed) with no display.

Product Details

  • Device Short Name
    BJ 060
  • Trip Unit Technology
    Thermal-magnetic
  • Color
    Grey (RAL 7016)
  • Product Name
    PowerPact B
  • [Ics] Rated Service Breaking Capacity
    65 kA 220...240 V AC 50/60 Hz IEC 60947-2
  • Electrical Durability
    10000 cycles IEC 947-1 Annex K ed 5.2 In
  • Range
    PowerPact
  • Suitability For Isolation
    Yes conforming to IEC 60947-2
  • Line Rated Current
    60 A
  • Trip Unit Name
    TM-D
  • Quantity Per Set
    Set of 1
  • Protected Poles Description
    1t
  • [Ui] Rated Insulation Voltage
    800 V IEC 60947-2
  • Power Wire Stripping Length
    0.79 in (20 mm)
  • Product Or Component Type
    Circuit breaker
  • [Uimp] Rated Impulse Withstand Voltage
    8 kV IEC 60947-2
  • Mechanical Durability
    15000 cycles IEC 947-1 Annex F ed 5.2
  • Height
    5.39 in (137 mm)
  • Number Of Poles
    1P
  • Connection Pitch
    1.06 in (27 mm)
  • Width
    1.06 in (27 mm)
  • Device Application
    Distribution
  • Continuous Current Rating
    80 %
  • Utilisation Category
    Category A
  • Depth
    3.15 in (80 mm)
  • Breaking Capacity Code
    J
  • Control Type
    Toggle
  • Net Weight
    1.12 lb(US) (0.51 kg)
  • 9 Mm Pitches
    3
  • Mounting Mode
    Clip-on 35 mm symmetrical DIN rail) By screws plate)
  • Electrical Connection
    Everlink lug line Everlink lug load
  • Tightening Torque
    44.25 lbf.in (5 N.m) 0.00…0.02 in² (2.5…16 mm²) (AWG 14...AWG 4) 79.66 lbf.in (9 N.m) 0.04…0.15 in² (25…95 mm²) (AWG 3...AWG 3/0)
  • AWG Gauge
    AWG 6...AWG 2/0 fine stranded aluminium/copper AWG 14...AWG 3/0 rigid or stranded aluminium/copper
  • [Ue] Rated Operational Voltage
    240 V AC 50/60 Hz UL 489 AC DC
  • Breaking Capacity
    100 kA 208Y/120 V AC 50/60 Hz UL 489 100 kA 240 V AC 50/60 Hz UL 489 65 kA 480Y/277 V AC 50/60 Hz UL 489 25 kA 600Y/347 V AC 50/60 Hz UL 489 50 kA 125 V DC UL 489

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of BJL16060 on Powermatic Associates is $874.50. Order now.



Similar products from: Schneider Electric Industrial Automation Components

Manufacturer warranty

BJL16060 Schneider Electric

$874.50

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$874.50

$874.50 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare BJL16060 with other Industrial Automation Components products

Device Short Name

Trip Unit Technology

Color

Product Name

[Ics] Rated Service Break...

Electrical Durability

Range

Suitability For Isolation

Line Rated Current

Trip Unit Name

Selected product

BJL16060
Backordered
BJL16060
Schneider Electric

Square D by Schneider Electric BJL16060 is a Moulded Case Circuit Breaker (MCCB) within the PowerPac...

Device Short NameBJ 060

Trip Unit TechnologyThermal-magnetic

ColorGrey (RAL 7016)

Product NamePowerPact B

[Ics] Rated Service Breaking Capacity65 kA 220...240 V AC 50/60 H...

Electrical Durability10000 cycles IEC 947-1 Annex...

RangePowerPact

Suitability For IsolationYes conforming to IEC 60947-...

Line Rated Current60 A

Trip Unit NameTM-D

BDF36015
4 in stock
BDF36015
Schneider Electric

Square D by Schneider Electric BDF36015 is a Moulded Case Circuit Breaker (MCCB) within the PowerPac...

Device Short NameBD 015

Trip Unit Technology-

Color-

Product NamePowerPact B

[Ics] Rated Service Breaking Capacity25 kA 220...240 V AC 50/60 H...

Electrical Durability-

RangePowerPact

Suitability For Isolation-

Line Rated Current15 A

Trip Unit Name-

BDF36100
7 in stock
BDF36100
Schneider Electric

Square D by Schneider Electric BDF36100 is a Moulded Case Circuit Breaker (MCCB) within the PowerPac...

Device Short NameBD 100

Trip Unit Technology-

Color-

Product NamePowerPact B

[Ics] Rated Service Breaking Capacity25 kA 220...240 V AC 50/60 H...

Electrical Durability-

RangePowerPact

Suitability For Isolation-

Line Rated Current100 A

Trip Unit Name-

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

Recently viewed products

Relevant products

BJL16090 on Powermatic Associates

BJL16090

Verified stock: 0

Square D by Schneider Electric BJL16090 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJL sub-range, featuring a PowerPact B-Frame 100 TMD 1P-1t 90A 600Y/347Vac 25kA with lugs rated at 80%. It has a rated impulse voltage (Uimp) of 8 kV and utilizes Everlink (Creep compensating) lugs for both line and load connections, ensuring a secure connection. This MCCB is designed with an IP40 degree of protection and supports a rated current of 90A with a rated voltage (AC) of 600Vac 600Y/347Vac. It boasts a mechanical durability of 15,000 operations at no load and can be mounted either on a DIN rail or as an individual unit on a plate. The device is a 1-pole (1P) unit with dimensions of 137 mm in height, 80 mm in depth, and 27 mm in width. It falls under the utilisation category A and offers protection settings including over-current fixed at 90A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage (DC) is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. Its protection functions include thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 90 AT. The electrical durability with load is rated for 10,000 operations at 240Vac; In, and the frame current rating is 100 AF. The operating mode is manual toggle, and it has a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all in accordance with UL489. The trip unit type is thermal-magnetic (fixed) without a display.

Schneider Electric

BJL16035 on Powermatic Associates

BJL16035

Verified stock: 0

Square D by Schneider Electric BJL16035 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJL sub-range, featuring a PowerPact B-Frame 100 TMD 1P-1t 35A 600Y/347Vac 25kA design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes Everlink (Creep compensating) lugs for connections on both line and load sides, offering a degree of protection of IP40. The rated current is 35A, with a rated voltage (AC) of 600Vac 600Y/347Vac. It is designed for mechanical durability of 15,000 operations at no load and can be mounted on a DIN rail or as an individual unit on a plate. This 1-pole (1P) circuit breaker has dimensions of 137 mm in height, 80 mm in depth, and 27 mm in width. It falls under utilisation category A and features protection settings for over-current fixed at 35A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage (DC) is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 35 AT. Its electrical durability with load is rated for 10,000 operations at 240Vac; In, and it has a frame current rating of 100 AF. The operating mode is toggle (manual), and it has a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

BJL16015 on Powermatic Associates

BJL16015

Verified stock: 0

Square D by Schneider Electric BJL16015 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJL sub-range, featuring a PowerPact B-Frame 100 TMD 1P-1t 15A 600Y/347Vac 25kA design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes Everlink (Creep compensating) lugs for connections on both line and load sides, offering a degree of protection of IP40. The rated current is 15A, with a rated voltage (AC) of 600Vac 600Y/347Vac. It is designed for mechanical durability up to 15,000 operations at no load and can be mounted either on a DIN rail or as an individual unit on a plate. This 1-pole (1P) circuit breaker has dimensions of 137 mm in height, 80 mm in depth, and 27 mm in width. It falls under utilisation category A and features protection settings including over-current fixed at 15A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage (DC) is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. Its protection functions include thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 15 AT. The electrical durability with load is rated for 10,000 operations at 240Vac; In, and the frame current rating is 100 AF. The operating mode is toggle (manual), and it has a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

BJL16050 on Powermatic Associates

BJL16050

Verified stock: 0

Square D by Schneider Electric BJL16050 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJL sub-range, featuring a PowerPact B-Frame 100 TMD 1P-1t 50A 600Y/347Vac 25kA design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes Everlink (Creep compensating) lugs for connections on both line and load sides, offering a degree of protection of IP40. The rated current is 50A, with a rated voltage (AC) of 600Vac 600Y/347Vac. It is designed for mechanical durability of 15,000 operations at no load and can be mounted on a DIN rail or as an individual unit on a plate. This 1-pole (1P) circuit breaker has dimensions of 137 mm in height, 80 mm in depth, and 27 mm in width. It falls under utilisation category A and features protection settings for over-current fixed at 50A, short-circuit hold current fixed at 480A, and short-circuit trip current fixed at 720A. The rated voltage (DC) is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. Its protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 50 AT. The electrical durability with load is rated for 10,000 operations at 240Vac; In, and the frame current rating is 100 AF. It operates via a toggle (manual) mode, with a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, and 25kA at 600Y/347Vac under UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

FAQ

What is the price of BJL16060?
Purchase the BJL16060 from Powermatic Associates at the price of $874.50. Order today.

Out if stock but available for backorder.

Square D by Schneider Electric BJL16060 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJL sub-range, featuring a PowerPact B-Frame 100 TMD 1P-1t 60A 600Y/347Vac 25kA design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes Everlink (Creep compensating) lugs for connections on both line and load sides, offering a degree of protection of IP40. The rated current is 60A, with a rated voltage (AC) of 600Vac 600Y/347Vac. It is designed for mechanical durability of 15,000 operations at no load and can be mounted on a DIN rail or individually on a plate. This 1-pole (1P) circuit breaker has dimensions of 137 mm in height, 80 mm in depth, and 27 mm in width. It falls under utilisation category A and features protection settings for over-current fixed at 60A, short-circuit hold current fixed at 640A, and short-circuit trip current fixed at 960A. The rated voltage (DC) is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. Its protection functions include thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 60 AT. The electrical durability with load is rated for 10,000 operations at 240Vac; In, and it has a frame current rating of 100 AF. The operating mode is manual toggle, and it has a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all in accordance with UL489. The trip unit type is thermal-magnetic (fixed) with no display.

Similar products from: Industrial Automation Components

What can I help you find today?

Recommended parts