BJL26050 Schneider Electric Industrial Automation Components

BJL26050 on Powermatic Associates
Schneider Electric

Part#:BJL26050

Manufacturer:Schneider Electric

Category:Industrial Automation Components

Product Lifecycle:Active

Product description

Square D by Schneider Electric BJL26050 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJL sub-range, featuring a PowerPact B-Frame 100 TMD 2P 50A 600Y/347Vac 25kA design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes Everlink (Creep compensating) lugs for connections on both line and load sides, offering a degree of protection of IP40. The rated current is 50A, with a rated voltage (AC) of 600Vac 600Y/347Vac. It boasts a mechanical durability of 20,000 operations at no load and can be mounted on a DIN rail or as an individual unit on a plate. This 2-pole (2P) circuit breaker has dimensions of 137 mm in height, 80 mm in depth, and 54 mm in width. It falls under utilisation category A and features protection settings for over-current fixed at 50A, short-circuit hold current fixed at 480A, and short-circuit trip current fixed at 720A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. Protection functions include thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 50 AT. Its electrical durability with load is rated at 10,000 operations at 440Vac; In, and it has a frame current rating of 100 AF. The operating mode is toggle (manual), and it has a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Product Details

  • Range
    PowerPact
  • Breaking Capacity Code
    J
  • Suitability For Isolation
    Yes IEC 60947-2
  • Electrical Durability
    10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
  • Height
    5.39 in (137 mm)
  • Line Rated Current
    50 A
  • Number Of Poles
    2P
  • Depth
    3.15 in (80 mm)
  • Continuous Current Rating
    80 %
  • Device Application
    Distribution
  • Device Short Name
    BJ 050
  • Utilisation Category
    Category A
  • Connection Pitch
    1.06 in (27 mm)
  • 9 Mm Pitches
    6
  • Product Name
    PowerPact B
  • [Ui] Rated Insulation Voltage
    800 V IEC 60947-2
  • Product Or Component Type
    Circuit breaker
  • [Ue] Rated Operational Voltage
    690 V AC 50/60 Hz UL 489
  • Local Signalling
    for presence of auxiliary contacts flag (green)
  • Net Weight
    1.70 lb(US) (0.769 kg)
  • Trip Unit Technology
    Thermal-magnetic
  • Quantity Per Set
    Set of 1
  • Control Type
    Toggle
  • [Uimp] Rated Impulse Withstand Voltage
    8 kV IEC 60947-2
  • Power Wire Stripping Length
    0.79 in (20 mm)
  • Width
    2.13 in (54 mm)
  • Mechanical Durability
    20000 cycles IEC 947-1 Annex K ed 5.2
  • Color
    Grey (RAL 7016)
  • Tightening Torque
    44.25 lbf.in (5 N.m) 0.00…0.02 in² (2.5…16 mm²) (AWG 14...AWG 4) 79.66 lbf.in (9 N.m) 0.04…0.15 in² (25…95 mm²) (AWG 3...AWG 3/0)
  • Electrical Connection
    Everlink lug line Everlink lug load
  • Number Of Slots
    1 auxiliary switch OF plug-in) 1 voltage release MN or MX plug-in)
  • AWG Gauge
    AWG 6...AWG 2/0 fine stranded aluminium/copper AWG 14...AWG 3/0 rigid or stranded aluminium/copper
  • Mounting Mode
    Clip-on 35 x 15 mm symmetrical DIN rail) By screws plate)
  • [Ics] Rated Service Breaking Capacity
    100 kA 220...240 V AC 50/60 Hz IEC 60947-2 25 kA 500...525 V AC 50/60 Hz IEC 60947-2 2.5 kA 690 V AC 50/60 Hz IEC 60947-2 65 kA 380...415 V AC 50/60 Hz IEC 60947-2 65 kA 440 V AC 50/60 Hz IEC 60947-2
  • Breaking Capacity
    100 kA 208Y/120 V AC 50/60 Hz UL 489 100 kA 240 V AC 50/60 Hz UL 489 65 kA 480/277 V AC 50/60 Hz UL 489 65 kA 480 V AC 50/60 Hz UL 489 25 kA 600Y/347 V AC 50/60 Hz UL 489 50 kA 250 V DC UL 489

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of BJL26050 on Powermatic Associates is $1,403.00. Order now.



Similar products from: Schneider Electric Industrial Automation Components

Manufacturer warranty

BJL26050 Schneider Electric

$1,403.00

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,403.00

$1,403.00 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare BJL26050 with other Industrial Automation Components products

Range

Breaking Capacity Code

Suitability For Isolation

Electrical Durability

Height

Line Rated Current

Number Of Poles

Depth

Continuous Current Rating

Device Application

Selected product

BJL26050
Backordered
BJL26050
Schneider Electric

Square D by Schneider Electric BJL26050 is a Moulded Case Circuit Breaker (MCCB) within the PowerPac...

RangePowerPact

Breaking Capacity CodeJ

Suitability For IsolationYes IEC 60947-2

Electrical Durability10000 cycles IEC 947-1 Annex...

Height5.39 in (137 mm)

Line Rated Current50 A

Number Of Poles2P

Depth3.15 in (80 mm)

Continuous Current Rating80 %

Device ApplicationDistribution

BDF36015
4 in stock
BDF36015
Schneider Electric

Square D by Schneider Electric BDF36015 is a Moulded Case Circuit Breaker (MCCB) within the PowerPac...

RangePowerPact

Breaking Capacity CodeD

Suitability For Isolation-

Electrical Durability-

Height-

Line Rated Current15 A

Number Of Poles3P

Depth-

Continuous Current Rating-

Device ApplicationDistribution

BDL36020
16 in stock
BDL36020
Schneider Electric

Square D by Schneider Electric BDL36020 is a Moulded Case Circuit Breaker (MCCB) within the PowerPac...

RangePowerPact

Breaking Capacity CodeD

Suitability For Isolation-

Electrical Durability-

Height-

Line Rated Current20 A

Number Of Poles3P

Depth-

Continuous Current Rating-

Device ApplicationDistribution

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

Recently viewed products

Relevant products

BJL26040LU on Powermatic Associates

BJL26040LU

Verified stock: 0

Square D by Schneider Electric BJL26040LU is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJL sub-range, featuring a PowerPact B-Frame 100 TMD 2P 40A 600Y/347Vac design with a 25kA rating and lugs with control wire on the end rated at 80%. It has an Everlink (Creep compensating) connection type with lugs on both line and load sides and a Control Wire terminal (CWT) on the line side only. This MCCB offers an IP40 degree of protection, a rated current of 40A, and a rated voltage of 600Vac 600Y/347Vac. It is designed for 20000 operations of mechanical durability at no load and can be mounted on a DIN rail or as an individual unit on a plate. The device has 2 poles (2P), dimensions of 137 mm in height, 80 mm in depth, and 54 mm in width. It falls under utilisation category A and offers protection settings including over-current fixed at 40A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage for DC applications is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. Its protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 40 AT. The electrical durability with load is rated for 10000 operations at 440Vac; In. The frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies with voltage, offering 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all under UL489. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

BJL26125LU on Powermatic Associates

BJL26125LU

Verified stock: 0

Square D by Schneider Electric BJL26125LU is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJL sub-range, featuring a PowerPact B-Frame 125 TMD 2P design. It has a rated current of 125A and operates at a rated voltage of 600Vac 600Y/347Vac, with a rated impulse voltage (Uimp) of 8 kV. The connection type includes Everlink (Creep compensating) lugs on both line and load sides, plus a Control Wire terminal (CWT) on the line side only. It offers a degree of protection of IP40 and is designed for mounting either fixed on DIN rail or as an individual unit mount on plate. This 2-pole (2P) circuit breaker has a net height of 137 mm, a net depth of 80 mm, and a net width of 54 mm. It is categorized under utilisation category A. The protection settings include over-current fixed at 125A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. It features thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 125 AT. The electrical durability with load is rated for 10,000 operations at 440Vac; In, and it has a mechanical durability of 20,000 operations at no load. The frame current rating is 125 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies with voltage, including 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, and 25kA at 600Y/347Vac under UL489 standards, with a 50kA rating at 250Vdc. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

FAQ

What is the price of BJL26050?
Purchase the BJL26050 from Powermatic Associates at the price of $1,403.00. Order today.

Out if stock but available for backorder.

Square D by Schneider Electric BJL26050 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJL sub-range, featuring a PowerPact B-Frame 100 TMD 2P 50A 600Y/347Vac 25kA design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes Everlink (Creep compensating) lugs for connections on both line and load sides, offering a degree of protection of IP40. The rated current is 50A, with a rated voltage (AC) of 600Vac 600Y/347Vac. It boasts a mechanical durability of 20,000 operations at no load and can be mounted on a DIN rail or as an individual unit on a plate. This 2-pole (2P) circuit breaker has dimensions of 137 mm in height, 80 mm in depth, and 54 mm in width. It falls under utilisation category A and features protection settings for over-current fixed at 50A, short-circuit hold current fixed at 480A, and short-circuit trip current fixed at 720A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. Protection functions include thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 50 AT. Its electrical durability with load is rated at 10,000 operations at 440Vac; In, and it has a frame current rating of 100 AF. The operating mode is toggle (manual), and it has a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.