LC1D40A6GD Schneider Electric Industrial Automation Components


Part#:LC1D40A6GD
Manufacturer:Schneider Electric
Category:Industrial Automation Components
Product Lifecycle:Active
Product description
Schneider Electric LC1D40A6GD is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminals and ring-lugs connections. It is designed with 3 poles (3P; 3NO) and has a rated current of 60A for AC-1 and 40A for AC-3 at 440Vac. This contactor is suitable for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection of IP20 and operates with a control voltage (DC) range of 94-156Vdc, nominally at 125Vdc. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. Its rated active power capacity spans from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3 operation. Additionally, it has 1 normally closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 30HP at 575-600Vac in three-phase operations, according to UL/CSA standards. The mechanical durability of the LC1D40A6GD is rated at 6 million operations at no load, and its electrical durability with load is rated at 1.5 million operations. The rated voltage for phase-to-phase connections is 690 V.
Product Details
- Motor Power Kw 18.5 kW 380...400 V AC 50/60 Hz AC-3) 11 kW 220...230 V AC 50/60 Hz AC-3) 22 kW 415...440 V AC 50/60 Hz AC-3) 22 kW 500 V AC 50/60 Hz AC-3) 30 kW 660...690 V AC 50/60 Hz AC-3) 9 kW 400 V AC 50/60 Hz AC-4)
- Motor Power HP (UL / CSA) 5 hp 230/240 V at AC 50/60 Hz for 1 phase 10 hp 230/240 V at AC 50/60 Hz for 3 phase 30 hp 575/600 V at AC 50/60 Hz for 3 phase 10 hp 200/208 V at AC 50/60 Hz for 3 phase 3 hp 115 V at AC 50/60 Hz for 1 phase 30 hp 460/480 V at AC
- [Ui] Rated Insulation Voltage Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 690 V IEC 60947-4-1
- [Icw] Rated Short-Time Withstand Current 320 A 104 °F (40 °C) - 10 s power circuit 720 A 104 °F (40 °C) - 1 s power circuit 72 A 104 °F (40 °C) - 10 min power circuit 165 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circ
- Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
- Product Certifications CSA UL CCC GOST
- Tightening Torque Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 53.10 lbf.in (6 N.m) lugs-ring terminals hexagonal 0.39 in (10 mm) M6
- Control Circuit Voltage Limits 0.1...0.3 Uc -40…158 °F (-40…70 °C) drop-out DC 0.75...1.25 Uc -40…140 °F (-40…60 °C) operational DC 1...1.25 Uc 140…158 °F (60…70 °C) operational DC
- Associated Fuse Rating 10 A gG signalling circuit IEC 60947-5-1 80 A gG <= 690 V type 1 power circuit 80 A gG <= 690 V type 2 power circuit
- Utilisation Category AC-1 AC-4 AC-3
- Irms Rated Making Capacity 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 800 A 440 V power circuit IEC 60947
- Electrical Durability 0.7 Mcycles 60 A AC-1 <= 440 V 1.5 Mcycles 40 A AC-3 <= 440 V
- Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Operating Time 42.5...57.5 ms closing 16...24 ms opening
- [Ie] Rated Operational Current 60 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit 40 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
- Connections - Terminals Control circuit lugs-ring terminals 0.31 in (8 mm)) Power circuit lugs-ring terminals 0.65 in (16.5 mm))
- Mounting Support Rail Plate
- Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
- Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
- [Ith] Conventional Free Air Thermal Current 10 A 140 °F (60 °C) signalling circuit 60 A 140 °F (60 °C) power circuit
- Power Dissipation Per Pole 2.4 W AC-3 5.4 W AC-1
- Contactor Application Resistive load Motor control
- [Ue] Rated Operational Voltage Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
- Signalling Circuit Frequency 25...400 Hz
- Minimum Switching Voltage 17 V signalling circuit
- Time Constant 34 ms
- Hold-In Power Consumption In W 7.4 W 68 °F (20 °C)
- Coil Technology Built-in bidirectional peak limiting diode suppressor
- Minimum Switching Current 5 mA signalling circuit
- Insulation Resistance > 10 MOhm signalling circuit
- Inrush Power In W 19 W 68 °F (20 °C))
- Maximum Operating Rate 3600 cyc/h 140 °F (60 °C)
- Mechanical Durability 10 Mcycles
- Front Cover With
- Average Impedance 1.5 mOhm - Ith 60 A 50 Hz power circuit
- Rated Breaking Capacity 800 A 440 V power circuit IEC 60947
- [Uc] Control Circuit Voltage 125 V DC
- Auxiliary Contact Composition 1 NO + 1 NC
- Overvoltage Category III
- [Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947
- Control Circuit Type DC standard
- Power Pole Contact Composition 3 NO
- Product Name TeSys D
- Poles Description 3P
- Device Short Name LC1D
- Product Or Component Type Contactor
- Range TeSys
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LC1D40A6GD on Powermatic Associates is $369.09. Order now.
LC1D40A6GD Related Documents
Similar products from: Schneider Electric Industrial Automation Components
Manufacturer warranty
LC1D40A6GD Schneider Electric
$369.09
Your price can be lower.
Log in or Create account to check your discount
Select Qty:
$369.09
$369.09 each
Average response time: 11 minutes
Worldwide Shipping and Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare LC1D40A6GD with other Industrial Automation Components products
Motor Power Kw
Motor Power HP (UL / CSA)
[Ui] Rated Insulation Vol...
[Icw] Rated Short-Time Wi...
Standards
Product Certifications
Tightening Torque
Control Circuit Voltage L...
Associated Fuse Rating
Utilisation Category
Selected product

LC1D40A6GD
Schneider Electric
Schneider Electric LC1D40A6GD is a magnetic contactor from the Deca sub-range featuring EverLink(TM)...
Motor Power Kw18.5 kW 380...400 V AC 50/60...
Motor Power HP (UL / CSA)5 hp 230/240 V at AC 50/60 H...
[Ui] Rated Insulation VoltagePower circuit 600 V CSA Powe...
[Icw] Rated Short-Time Withstand Current320 A 104 °F (40 °C) - 10 s ...
StandardsCSA C22.2 No 14 EN 60947-4-1...
Product CertificationsCSA UL CCC GOST
Tightening TorqueControl circuit 15.05 lbf.in...
Control Circuit Voltage Limits0.1...0.3 Uc -40…158 °F (-40...
Associated Fuse Rating10 A gG signalling circuit I...
Utilisation CategoryAC-1 AC-4 AC-3
About the manufacturer
Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...
Recently viewed products
Relevant products
FAQ
What is the price of LC1D40A6GD?
Purchase the LC1D40A6GD from Powermatic Associates at the price of $369.09. Order today.
Out if stock but available for backorder.
Schneider Electric LC1D40A6GD is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminals and ring-lugs connections. It is designed with 3 poles (3P; 3NO) and has a rated current of 60A for AC-1 and 40A for AC-3 at 440Vac. This contactor is suitable for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection of IP20 and operates with a control voltage (DC) range of 94-156Vdc, nominally at 125Vdc. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. Its rated active power capacity spans from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3 operation. Additionally, it has 1 normally closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 30HP at 575-600Vac in three-phase operations, according to UL/CSA standards. The mechanical durability of the LC1D40A6GD is rated at 6 million operations at no load, and its electrical durability with load is rated at 1.5 million operations. The rated voltage for phase-to-phase connections is 690 V.
Similar products from: Industrial Automation Components
What can I help you find today?