LC1D50A6F7 Schneider Electric Industrial Automation Components

LC1D50A6F7 on Powermatic Associates
Schneider Electric

Part#:LC1D50A6F7

Manufacturer:Schneider Electric

Category:Industrial Automation Components

Product Lifecycle:Active

Product description

Schneider Electric LC1D50A6F7 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminal design for ring-lugs connections. This 3-pole (3P; 3NO) contactor supports a rated current of 80A in AC-1 and 50A in 440Vac AC-3 applications. It is designed for DIN rail mounting with a net width of 55 mm and offers an IP20 degree of protection. The control voltage (AC) ranges from 88-121Vac at 50Hz and 93.5-121Vac at 60Hz, with a rated operating voltage (Ue) of 690 V. It includes 1 normally open (NO) and 1 normally closed (NC) auxiliary contacts, with a contacts type of 1NO+1NC instantaneous aux. The rated impulse voltage (Uimp) is 6 kV, and it has a rated active power of up to 33kW in 660-690Vac AC-3 applications. The rated power in horsepower (HP) varies from 3HP in 115Vac single-phase to 40HP in 575-600Vac 3-phase applications, under UL/CSA standards. This contactor is built to withstand 6,000,000 mechanical operations at no load and 1,450,000 electrical operations with load, with a phase-to-phase rated voltage of 690 V.

Product Details

  • Minimum Switching Current
    5 mA signalling circuit
  • Power Pole Contact Composition
    3 NO
  • [Uimp] Rated Impulse Withstand Voltage
    6 kV IEC 60947
  • Front Cover
    With
  • Minimum Switching Voltage
    17 V signalling circuit
  • Range
    TeSys
  • [Uc] Control Circuit Voltage
    110 V AC 50/60 Hz
  • Rated Breaking Capacity
    900 A 440 V power circuit IEC 60947
  • Insulation Resistance
    > 10 MOhm for signalling circuit
  • Coil Technology
    Without built-in suppressor module
  • Product Or Component Type
    Contactor
  • Control Circuit Type
    AC at 50/60 Hz
  • Heat Dissipation
    4…5 W 50/60 Hz
  • Poles Description
    3P
  • Average Impedance
    1.5 mOhm - Ith 80 A 50 Hz power circuit
  • Mechanical Durability
    6 Mcycles
  • Product Name
    TeSys D
  • Auxiliary Contact Composition
    1 NO + 1 NC
  • Maximum Operating Rate
    3600 cyc/h 140 °F (60 °C)
  • Device Short Name
    LC1D
  • Overvoltage Category
    III
  • [Ui] Rated Insulation Voltage
    Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 690 V IEC 60947-4-1
  • Signalling Circuit Frequency
    25...400 Hz
  • Inrush Power In VA
    140 VA 60 Hz 0.75 68 °F (20 °C)) 160 VA 50 Hz 0.75 68 °F (20 °C))
  • Contactor Application
    Resistive load Motor control
  • [Ith] Conventional Free Air Thermal Current
    10 A 140 °F (60 °C) signalling circuit 80 A 140 °F (60 °C) power circuit
  • Auxiliary Contacts Type
    Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
  • Operating Time
    4...19 ms opening 12...26 ms closing
  • Electrical Durability
    1.45 Mcycles 50 A AC-3 <= 440 V 1.1 Mcycles 80 A AC-1 <= 440 V
  • [Ue] Rated Operational Voltage
    Power circuit: <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
  • Safety Reliability Level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Mounting Support
    Rail Plate
  • Power Dissipation Per Pole
    3.7 W AC-3 9.6 W AC-1
  • [Ie] Rated Operational Current
    50 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit 80 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
  • Non-Overlap Time
    1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
  • Connections - Terminals
    Control circuit lugs-ring terminals 0.31 in (8 mm)) Power circuit lugs-ring terminals 0.65 in (16.5 mm))
  • Hold-In Power Consumption In VA
    13 VA 60 Hz 0.3 68 °F (20 °C)) 15 VA 50 Hz 0.3 68 °F (20 °C))
  • Associated Fuse Rating
    10 A gG signalling circuit IEC 60947-5-1 100 A gG <= 690 V type 1 power circuit 100 A gG <= 690 V type 2 power circuit
  • Utilisation Category
    AC-3 AC-1 AC-4
  • Tightening Torque
    Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 53.10 lbf.in (6 N.m) lugs-ring terminals hexagonal 0.39 in (10 mm) M6
  • Irms Rated Making Capacity
    140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 900 A 440 V power circuit IEC 60947
  • Control Circuit Voltage Limits
    0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
  • [Icw] Rated Short-Time Withstand Current
    400 A 104 °F (40 °C) - 10 s power circuit 810 A 104 °F (40 °C) - 1 s power circuit 84 A 104 °F (40 °C) - 10 min power circuit 208 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circ
  • Motor Power HP (UL / CSA)
    3 hp 115 V at AC 50/60 Hz for 1 phase 7.5 hp 230/240 V at AC 50/60 Hz for 1 phase 15 hp 200/208 V at AC 50/60 Hz for 3 phase 15 hp 230/240 V at AC 50/60 Hz for 3 phase 40 hp 460/480 V at AC 50/60 Hz for 3 phase 40 hp 575/600 V at
  • Standards
    CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
  • Motor Power Kw
    15 kW 220...230 V AC 50/60 Hz AC-3) 22 kW 380...400 V AC 50/60 Hz AC-3) 30 kW 500 V AC 50/60 Hz AC-3) 33 kW 660...690 V AC 50/60 Hz AC-3) 25 kW 415 V AC 50/60 Hz AC-3) 30 kW 440 V AC 50/60 Hz AC-3) 11 kW 400 V AC 50/60 Hz AC-
  • Product Certifications
    GOST DNV RINA CSA CCC UL LROS (Lloyds register of shipping) BV GL

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LC1D50A6F7 on Powermatic Associates is $330.09. Order now.



Similar products from: Schneider Electric Industrial Automation Components

Manufacturer warranty

LC1D50A6F7 Schneider Electric

$330.09

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$330.09

$330.09 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare LC1D50A6F7 with other Industrial Automation Components products

Minimum Switching Current

Power Pole Contact Compos...

[Uimp] Rated Impulse With...

Front Cover

Minimum Switching Voltage

Range

[Uc] Control Circuit Volt...

Rated Breaking Capacity

Insulation Resistance

Coil Technology

Selected product

LC1D50A6F7
Backordered
LC1D50A6F7
Schneider Electric

Schneider Electric LC1D50A6F7 is a magnetic contactor from the Deca sub-range featuring EverLink(TM)...

Minimum Switching Current5 mA signalling circuit

Power Pole Contact Composition3 NO

[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947

Front CoverWith

Minimum Switching Voltage17 V signalling circuit

RangeTeSys

[Uc] Control Circuit Voltage110 V AC 50/60 Hz

Rated Breaking Capacity900 A 440 V power circuit IE...

Insulation Resistance> 10 MOhm for signalling cir...

Coil TechnologyWithout built-in suppressor ...

LC1D40ABD
2 in stock
LC1D40ABD
Schneider Electric

Schneider Electric LC1D40ABD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM)...

Minimum Switching Current-

Power Pole Contact Composition3 NO

[Uimp] Rated Impulse Withstand Voltage-

Front Cover-

Minimum Switching Voltage-

RangeTeSys

[Uc] Control Circuit Voltage24 V DC

Rated Breaking Capacity-

Insulation Resistance-

Coil Technology-

LC1D126BL
7 in stock
LC1D126BL
Schneider Electric

Schneider Electric LC1D126BL is a magnetic contactor from the Deca sub-range designed with a low-con...

Minimum Switching Current-

Power Pole Contact Composition3 NO

[Uimp] Rated Impulse Withstand Voltage-

Front Cover-

Minimum Switching Voltage-

RangeTeSys

[Uc] Control Circuit Voltage24 V DC

Rated Breaking Capacity-

Insulation Resistance-

Coil Technology-

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

Recently viewed products

LGF36600U31XAAUOYH1 on Powermatic Associates

LGF36600U31XAAUOYH1

Schneider Electric

Square D by Schneider Electric LGF36600U31XAAUOYH1 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT LGF sub-range. It features a factory-installed 24Vdc undervoltage (U/V) trip release coil and a factory-installed 1A/1B (1NO+1NC) auxiliary switch OF wire harness. Designed for PowerPacT L-Frame 600 Micrologic 3.3 (LI), this 3-pole (3P) circuit breaker is rated for 600A and 600Vac, with a busbar rating of 80% and an 18kA busbar. It offers long-time (L) and instantaneous (I) protection functions, with a rated insulation voltage (Ui) of 750 V and a rated voltage (AC) of 600Vac 600Y/347Vac. The unit is designed for individual unit mount on plate, with a net height of 382 mm, width of 153 mm, and depth of 171 mm. It has an IP40 degree of protection and operates manually via a toggle. Protection settings include L - Protection against overload adjustable from 0.3 to 1 x In (50A to 150A) and I - Instantaneous protection against short-circuit adjustable from 1.5 to 11 x In (900A to 6600A). The control voltage (AC) specification indicates that the circuit breaker opens instantaneously when the undervoltage trip supply voltage drops between 35% and 70% of its rated control voltage, allowing closing when the supply voltage reaches 85% of rated control voltage. The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 600 AT, with a frame current rating of 600 AF. It has a short circuit breaking rating of 65kA at 240Vac, 35kA at 480Vac, 35kA at 480Y/277Vac, 18kA at 600Vac, 18kA at 600Y/347Vac, and 20kA at 500Vdc, all according to UL489 standards. The trip unit type is an electronic Micrologic Standard 3.3 (LI) with LI protection and no display, categorized under utilisation category A.

5 in stock

Relevant products

FAQ

What is the price of LC1D50A6F7?
Purchase the LC1D50A6F7 from Powermatic Associates at the price of $330.09. Order today.

Out if stock but available for backorder.

Schneider Electric LC1D50A6F7 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminal design for ring-lugs connections. This 3-pole (3P; 3NO) contactor supports a rated current of 80A in AC-1 and 50A in 440Vac AC-3 applications. It is designed for DIN rail mounting with a net width of 55 mm and offers an IP20 degree of protection. The control voltage (AC) ranges from 88-121Vac at 50Hz and 93.5-121Vac at 60Hz, with a rated operating voltage (Ue) of 690 V. It includes 1 normally open (NO) and 1 normally closed (NC) auxiliary contacts, with a contacts type of 1NO+1NC instantaneous aux. The rated impulse voltage (Uimp) is 6 kV, and it has a rated active power of up to 33kW in 660-690Vac AC-3 applications. The rated power in horsepower (HP) varies from 3HP in 115Vac single-phase to 40HP in 575-600Vac 3-phase applications, under UL/CSA standards. This contactor is built to withstand 6,000,000 mechanical operations at no load and 1,450,000 electrical operations with load, with a phase-to-phase rated voltage of 690 V.

Similar products from: Industrial Automation Components

What can I help you find today?

Recommended parts