LRD07L6 Schneider Electric Industrial Automation Components

LRD07L6 on Powermatic Associates
Schneider Electric

Part#:LRD07L6

Manufacturer:Schneider Electric

Category:Industrial Automation Components

Product Lifecycle:Active

Product description

Schneider Electric LRD07L6 is a differential thermal overload relay belonging to the LRD sub-range, designed for direct connection to a contactor with outgoing cables connected via lugs and a control circuit utilizing screw-clamp terminals. This 3-pole device offers protection functions classified as Class 20, with a rated current range of 1.6-2.5 A. It features protection settings for thermal overload within the same range, supplemented by 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. The rated voltage for phase-to-phase operation spans up to 690 V at frequencies from 0 to 400Hz, with a minimum operating current of 1.6 A and a maximum of 2.5 A.

Product Details

  • Relay Application
    Motor protection
  • Auxiliary Contact Composition
    1 NO + 1 NC
  • Width
    1.77 in (45 mm)
  • Product Or Component Type
    Differential thermal overload relay
  • Thermal Protection Adjustment Range
    1.6…2.5 A
  • [Uimp] Rated Impulse Withstand Voltage
    6 kV
  • Range
    TeSys
  • Temperature Compensation
    -4…140 °F (-20…60 °C)
  • Phase Failure Sensitivity
    Tripping current 130 % of Ir on two phase, the last one at 0
  • Device Short Name
    LRD
  • Tripping Threshold
    1.14 +/- 0.06 Ir IEC 60947-4-1
  • Product Name
    TeSys LRD
  • Network Frequency
    0...400 Hz
  • Thermal Overload Class
    Class 20 IEC 60947-4-1
  • Depth
    2.99 in (76 mm)
  • [Ue] Rated Operational Voltage
    690 V AC 0...400 Hz power circuit IEC 60947-4-1
  • Net Weight
    0.32 lb(US) (0.144 kg)
  • [Ith] Conventional Free Air Thermal Current
    5 A signalling circuit
  • Height
    2.60 in (66 mm)
  • Network Type
    AC DC
  • Associated Fuse Rating
    4 A gG signalling circuit 4 A BS signalling circuit
  • Control Type
    Red push-button stop Blue push-button reset
  • Tightening Torque
    Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Power circuit 20.36 lbf.in (2.3 N.m) lugs-ring terminals M4
  • Permissible Current
    3 A 120 V AC-15 signalling circuit 0.22 A 125 V DC-13 signalling circuit
  • [Ui] Rated Insulation Voltage
    Power circuit 600 V CSA Power circuit 600 V UL Power circuit 690 V IEC 60947-4-1
  • Mounting Support
    Plate, with specific accessories Rail, with specific accessories Under contactor
  • Connections - Terminals
    Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible without cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 m
  • Product Compatibility
    LC1D09 LC1D25 LC1D32 LC1D38 LC1D12 LC1D18

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LRD07L6 on Powermatic Associates is $101.35. Order now.



Similar products from: Schneider Electric Industrial Automation Components

Manufacturer warranty

LRD07L6 Schneider Electric

$101.35

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$101.35

$101.35 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare LRD07L6 with other Industrial Automation Components products

Relay Application

Auxiliary Contact Composi...

Width

Product Or Component Type

Thermal Protection Adjust...

[Uimp] Rated Impulse With...

Range

Temperature Compensation

Phase Failure Sensitivity

Device Short Name

Selected product

LRD07L6
Backordered
LRD07L6
Schneider Electric

Schneider Electric LRD07L6 is a differential thermal overload relay belonging to the LRD sub-range, ...

Relay ApplicationMotor protection

Auxiliary Contact Composition1 NO + 1 NC

Width1.77 in (45 mm)

Product Or Component TypeDifferential thermal overloa...

Thermal Protection Adjustment Range1.6…2.5 A

[Uimp] Rated Impulse Withstand Voltage6 kV

RangeTeSys

Temperature Compensation-4…140 °F (-20…60 °C)

Phase Failure SensitivityTripping current 130 % of Ir...

Device Short NameLRD

LR9D08
1 in stock
LR9D08
Schneider Electric

Schneider Electric LR9D08 is an electronic thermal overload relay designed for direct connection to ...

Relay ApplicationMotor protection

Auxiliary Contact Composition-

Width-

Product Or Component TypeElectronic thermal overload ...

Thermal Protection Adjustment Range1.6…8 A

[Uimp] Rated Impulse Withstand Voltage-

RangeTeSys

Temperature Compensation-

Phase Failure Sensitivity-

Device Short NameLR9D

DF101
10 in stock
DF101
Schneider Electric

Schneider Electric - DF101

Relay Application-

Auxiliary Contact Composition-

Width-

Product Or Component TypeFuse carrier

Thermal Protection Adjustment Range-

[Uimp] Rated Impulse Withstand Voltage-

RangeTeSys

Temperature Compensation-

Phase Failure Sensitivity-

Device Short NameDF10

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

Recently viewed products

Relevant products

FAQ

What is the price of LRD07L6?
Purchase the LRD07L6 from Powermatic Associates at the price of $101.35. Order today.

Out if stock but available for backorder.

Schneider Electric LRD07L6 is a differential thermal overload relay belonging to the LRD sub-range, designed for direct connection to a contactor with outgoing cables connected via lugs and a control circuit utilizing screw-clamp terminals. This 3-pole device offers protection functions classified as Class 20, with a rated current range of 1.6-2.5 A. It features protection settings for thermal overload within the same range, supplemented by 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. The rated voltage for phase-to-phase operation spans up to 690 V at frequencies from 0 to 400Hz, with a minimum operating current of 1.6 A and a maximum of 2.5 A.

Similar products from: Industrial Automation Components

What can I help you find today?

Recommended parts