Product description

Square D by Schneider Electric BGF26050 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGF sub-range. It features a PowerPact B-Frame 100 TMD 2P-2t design, with a rated current of 50A and a rated voltage of 600Vac 600Y/347Vac. The breaker is designed for fixed busbar connection with a term. nut kit on both line and load sides, offering a degree of protection of IP40. It has a mechanical durability of 15,000 operations and can be mounted on a DIN rail or as an individual unit on a plate. This 2-pole (2P) device has a net height of 137 mm, a net depth of 80 mm, and a net width of 54 mm. It operates in utilisation category A and features over-current protection fixed at 50A, short-circuit hold current fixed at 480A, and short-circuit trip current fixed at 720A. The rated insulation voltage (Ui) is 800 V, with a rated operating voltage (Ue) of 525 V. It provides thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 50 AT. The electrical durability with load is 10,000 operations at 440Vac. Its frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies with voltage, up to 65kA at 240Vac and down to 18kA at 600Y/347Vac, including a 20kA rating at 250Vdc, all under UL489. The trip unit type is thermal-magnetic (fixed) without a display.

Product Details

  • Device Application
    Distribution
  • [Uimp] Rated Impulse Withstand Voltage
    8 kV IEC 60947-2
  • Mechanical Durability
    15000 cycles IEC 947-1 Annex K ed 5.2
  • Electrical Connection
    Terminal nut ON and OFF end
  • Line Rated Current
    50 A
  • [Ue] Rated Operational Voltage
    525 V AC 50/60 Hz UL 489
  • Power Wire Stripping Length
    0.79 in (20 mm)
  • Range
    PowerPact
  • Utilisation Category
    Category A
  • Product Or Component Type
    Circuit breaker
  • Protected Poles Description
    2t
  • Continuous Current Rating
    80 %
  • Electrical Durability
    10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
  • Color
    Gray RAL 7016)
  • Number Of Poles
    2P
  • Breaking Capacity Code
    G
  • Connection Pitch
    1.06 in (27 mm)
  • Control Type
    Toggle
  • Trip Unit Name
    TM-D
  • Height
    5.39 in (137 mm)
  • Device Short Name
    BG 050
  • Product Name
    PowerPact B
  • [Ui] Rated Insulation Voltage
    800 V IEC 60947-2
  • Local Signalling
    for presence of auxiliary contacts flag (green)
  • Width
    2.13 in (54 mm)
  • Suitability For Isolation
    Yes conforming to IEC 60947-2
  • Trip Unit Technology
    Thermal-magnetic
  • Net Weight
    1.47 lb(US) (0.669 kg)
  • 9 Mm Pitches
    6
  • Depth
    3.15 in (80 mm)
  • Quantity Per Set
    Set of 1
  • Number Of Slots
    1 auxiliary switch OF plug-in) 1 voltage release MN or MX plug-in)
  • AWG Gauge
    AWG 14...AWG 8 aluminium/copper AWG 6...AWG 3/0 aluminium/copper
  • Tightening Torque
    44.25 lbf.in (5 N.m) 0.00…0.02 in² (2.5…16 mm²) (AWG 14...AWG 4) 79.66 lbf.in (9 N.m) 0.04…0.15 in² (25…95 mm²) (AWG 3...AWG 3/0)
  • Mounting Mode
    Clip-on 35 mm symmetrical DIN rail) By screws plate)
  • [Ics] Rated Service Breaking Capacity
    65 kA 220...240 V AC 50/60 Hz IEC 60947-2 18 kA 500...525 V AC 50/60 Hz IEC 60947-2 35 kA 380...415 V AC 50/60 Hz IEC 60947-2 35 kA 440 V AC 50/60 Hz IEC 60947-2
  • Breaking Capacity
    65 kA 208Y/120 V AC 50/60 Hz UL 489 65 kA 240 V AC 50/60 Hz UL 489 35 kA 480/277 V AC 50/60 Hz UL 489 35 kA 480 V AC 50/60 Hz UL 489 20 kA 250 V DC UL 489 18 kA 600Y/347 V AC 50/60 Hz UL 489

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Similar products from: Schneider Electric Electronic Components

Manufacturer warranty

BGF26050 Schneider Electric

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare BGF26050 with other Electronic Components products

Device Application

[Uimp] Rated Impulse With...

Mechanical Durability

Electrical Connection

Line Rated Current

[Ue] Rated Operational Vo...

Power Wire Stripping Leng...

Range

Utilisation Category

Product Or Component Type

Selected product

BGF26050
Backordered
BGF26050
Schneider Electric

Square D by Schneider Electric BGF26050 is a Moulded Case Circuit Breaker (MCCB) within the PowerPac...

Device ApplicationDistribution

[Uimp] Rated Impulse Withstand Voltage8 kV IEC 60947-2

Mechanical Durability15000 cycles IEC 947-1 Annex...

Electrical ConnectionTerminal nut ON and OFF end

Line Rated Current50 A

[Ue] Rated Operational Voltage525 V AC 50/60 Hz UL 489

Power Wire Stripping Length0.79 in (20 mm)

RangePowerPact

Utilisation CategoryCategory A

Product Or Component TypeCircuit breaker

BJF36035
7 in stock
BJF36035
Schneider Electric

Square D by Schneider Electric BJF36035 is a Moulded Case Circuit Breaker (MCCB) within the PowerPac...

Device ApplicationDistribution

[Uimp] Rated Impulse Withstand Voltage8 kV IEC 60947-2

Mechanical Durability-

Electrical Connection-

Line Rated Current35 A

[Ue] Rated Operational Voltage-

Power Wire Stripping Length-

RangePowerPact

Utilisation Category-

Product Or Component TypeCircuit breaker

M9U31110
1 in stock
M9U31110
Schneider Electric

Schneider Electric M9U31110 is a Miniature Circuit Breaker (MCB) designed specifically for DC loads,...

Device ApplicationDistribution

[Uimp] Rated Impulse Withstand Voltage6 kVEN/IEC 60947-2

Mechanical Durability-

Electrical Connection-

Line Rated Current10 A 77 °F (25 °C) EN/IEC 60...

[Ue] Rated Operational Voltage-

Power Wire Stripping Length-

RangeMulti 9

Utilisation Category-

Product Or Component TypeMiniature circuit-breaker

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

Recently viewed products

Relevant products

BGF26020 on Powermatic Associates

BGF26020

Verified stock: 0

Square D by Schneider Electric BGF26020 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGF sub-range, featuring a PowerPact B-Frame 100 TMD 2P-2t design. It has a rated current of 20A and operates at a rated voltage of 600Vac 600Y/347Vac, with a rated impulse voltage (Uimp) of 8 kV. The connection type is a terminal nut kit for fixed busbar connection on both line and load sides, offering a degree of protection of IP40. This MCCB has a mechanical durability of 15,000 operations and can be mounted either on a DIN rail or as an individual unit on a plate. It is a 2-pole (2P) device with dimensions of 137 mm in height, 80 mm in depth, and 54 mm in width. The utilisation category is A, and it features over-current protection fixed at 20A, short-circuit hold current protection fixed at 400A, and short-circuit trip current protection fixed at 600A. The rated voltage for DC applications is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. It offers thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 20 AT. The electrical durability with load is 10,000 operations at 440Vac. The frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies with voltage, achieving 65kA at 240Vac, 35kA at 480Vac, 35kA at 480Y/277Vac, and 18kA at both 600Y/347Vac and 250Vdc, all under UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display.

Schneider Electric

BGF26100 on Powermatic Associates

BGF26100

Verified stock: 0

Square D by Schneider Electric BGF26100 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGF sub-range, featuring a PowerPact B-Frame 100 TMD 2P-2t design. It has a rated current of 100A and operates at a rated voltage of 600Vac 600Y/347Vac, with a rated impulse voltage (Uimp) of 8 kV. The connection type is a terminal nut kit for fixed busbar connection on both line and load sides, offering a degree of protection of IP40. This MCCB has a mechanical durability of 15,000 operations and can be mounted either on a DIN rail or as an individual unit on a plate. It has 2 poles (2P) and falls under the utilization category A. The dimensions are 137 mm in height, 80 mm in depth, and 54 mm in width. Its protection settings include over-current fixed at 100A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage for DC applications is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. It provides thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 100 AT. The electrical durability with load is 10,000 operations at 440Vac. The frame current rating is 100 AF, and it operates via a toggle (manual). The short circuit breaking rating varies with voltage: 65kA at 240Vac, 35kA at 480Vac and 480Y/277Vac, and 18kA at 600Y/347Vac, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display.

Schneider Electric

BGF26025 on Powermatic Associates

BGF26025

Verified stock: 0

Square D by Schneider Electric BGF26025 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGF sub-range, featuring a PowerPact B-Frame 100 TMD 2P-2t design with a rated current of 25A and a rated voltage of 600Vac 600Y/347Vac. It has a rated impulse voltage (Uimp) of 8 kV and offers a connection via Term. nut kit for fixed busbar connection on both line and load sides. The degree of protection provided is IP40. This MCCB has a mechanical durability of 15,000 operations and can be mounted either on a DIN rail or as an individual unit on a plate. It is a 2-pole (2P) device with dimensions of 137 mm in height, 80 mm in depth, and 54 mm in width. The utilisation category is A. It features over-current protection fixed at 25A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage for DC applications is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. Protection functions include thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 25 AT. Its electrical durability with load is rated at 10,000 operations at 440Vac. The frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies with voltage: 65kA at 240Vac, 35kA at 480Vac and 480Y/277Vac, and 18kA at 600Y/347Vac, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

BGF26060 on Powermatic Associates

BGF26060

Verified stock: 0

Square D by Schneider Electric BGF26060 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGF sub-range, featuring a PowerPact B-Frame 100 TMD 2P-2t 60A 600Y/347Vac 18kA terminal nut 80% rated design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes a terminal nut kit for fixed busbar connection on both line and load sides. The degree of protection offered is IP40, with a rated current of 60A and a rated voltage (AC) of 600Vac 600Y/347Vac. This MCCB is designed for fixed mounting on DIN rail or as an individual unit mount on a plate, featuring 2 poles (2P). It has a net height of 137 mm, a net depth of 80 mm, and a net width of 54 mm. The utilisation category is A. Protection settings include over-current fixed at 60A, short-circuit hold current fixed at 640A, and short-circuit trip current fixed at 960A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. Protection functions encompass thermal protection (overload) and magnetic protection (short-circuit), with a trip current rating of 60 AT. It has an electrical durability (with load) of 10,000 operations at 440Vac; In, and a frame current rating of 100 AF. The operating mode is toggle (manual), and it has a short circuit breaking rating of 65kA at 240Vac, 35kA at 480Vac, 35kA at 480Y/277Vac, and 18kA at 600Y/347Vac under UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

FAQ

Out if stock but available for backorder.

Square D by Schneider Electric BGF26050 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGF sub-range. It features a PowerPact B-Frame 100 TMD 2P-2t design, with a rated current of 50A and a rated voltage of 600Vac 600Y/347Vac. The breaker is designed for fixed busbar connection with a term. nut kit on both line and load sides, offering a degree of protection of IP40. It has a mechanical durability of 15,000 operations and can be mounted on a DIN rail or as an individual unit on a plate. This 2-pole (2P) device has a net height of 137 mm, a net depth of 80 mm, and a net width of 54 mm. It operates in utilisation category A and features over-current protection fixed at 50A, short-circuit hold current fixed at 480A, and short-circuit trip current fixed at 720A. The rated insulation voltage (Ui) is 800 V, with a rated operating voltage (Ue) of 525 V. It provides thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 50 AT. The electrical durability with load is 10,000 operations at 440Vac. Its frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies with voltage, up to 65kA at 240Vac and down to 18kA at 600Y/347Vac, including a 20kA rating at 250Vdc, all under UL489. The trip unit type is thermal-magnetic (fixed) without a display.

Similar products from: Electronic Components

What can I help you find today?

Recommended parts