HGA260251 Schneider Electric Electronic Components


Part#:HGA260251
Manufacturer:Schneider Electric
Category:Electronic Components
Product Lifecycle:Active
Product description
Square D by Schneider Electric HGA260251 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT HGA sub-range, designed as a PowerPact H-Frame 150 TMD 2P 25A 600Vac/500Vdc 18kA I-line AB with an 80% rating. It features a 2-pole (2P) configuration with I-line connection (AB phases) for mounting. This MCCB offers thermal protection for overload scenarios and magnetic protection against short-circuits, with a rated current of 25A. The rated insulation voltage (Ui) is 750 V, with AC rated voltages of 600Vac and 600Y/347Vac, and a DC rated voltage of 500Vdc. It mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism, ensuring a robust attachment. The net dimensions are 163 mm in height, 104 mm in width, and 86 mm in depth, with an IP40 degree of protection. Operation is manual via a toggle, with over-current protection fixed at 25A and short-circuit protection settings fixed at 350A for hold current and 750A for trip current. The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 25 AT, with a frame current rating of 150 AF. Short circuit breaking ratings include 65kA at 240Vac, 35kA at 480Vac and 480Y/277Vac, 18kA at 600Vac and 600Y/347Vac, and 20kA at 250Vdc and 500Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display, and it falls under utilisation category A.
Product Details
- Electrical Connection I-Line connection line Lugs load
- Width 2.94 in (74.68 mm)
- Depth 4.8 in (121.92 mm)
- Continuous Current Rating 80 %
- Height 9.73 in (247.14 mm)
- Tightening Torque 44.25 lbf.in (5 N.m) 0.00…0.15 in² (2.5…95 mm²) (AWG 14...AWG 3/0)
- Phase Connection AB
- Number Of Poles 2P
- Mounting Mode I-Line
- Magnetic Tripping Current 750 A
- Magnetic Hold Current 350 A
- Product Or Component Type Circuit breaker
- Breaking Capacity Code G
- Line Rated Current 25 A
- Range Of Product PowerPact H
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
HGA260251 Related Documents
Similar products from: Schneider Electric Electronic Components
Manufacturer warranty
HGA260251 Schneider Electric
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Worldwide Shipping and Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare HGA260251 with other Electronic Components products
Electrical Connection
Width
Depth
Continuous Current Rating
Height
Tightening Torque
Phase Connection
Number Of Poles
Mounting Mode
Magnetic Tripping Current
Selected product

HGA260251
Schneider Electric
Square D by Schneider Electric HGA260251 is a Moulded Case Circuit Breaker (MCCB) within the PowerPa...
Electrical ConnectionI-Line connection line Lugs ...
Width2.94 in (74.68 mm)
Depth4.8 in (121.92 mm)
Continuous Current Rating80 %
Height9.73 in (247.14 mm)
Tightening Torque44.25 lbf.in (5 N.m) 0.00…0....
Phase ConnectionAB
Number Of Poles2P
Mounting ModeI-Line
Magnetic Tripping Current750 A
About the manufacturer
Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...
Recently viewed products
Relevant products
FAQ
Out if stock but available for backorder.
Square D by Schneider Electric HGA260251 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT HGA sub-range, designed as a PowerPact H-Frame 150 TMD 2P 25A 600Vac/500Vdc 18kA I-line AB with an 80% rating. It features a 2-pole (2P) configuration with I-line connection (AB phases) for mounting. This MCCB offers thermal protection for overload scenarios and magnetic protection against short-circuits, with a rated current of 25A. The rated insulation voltage (Ui) is 750 V, with AC rated voltages of 600Vac and 600Y/347Vac, and a DC rated voltage of 500Vdc. It mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism, ensuring a robust attachment. The net dimensions are 163 mm in height, 104 mm in width, and 86 mm in depth, with an IP40 degree of protection. Operation is manual via a toggle, with over-current protection fixed at 25A and short-circuit protection settings fixed at 350A for hold current and 750A for trip current. The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 25 AT, with a frame current rating of 150 AF. Short circuit breaking ratings include 65kA at 240Vac, 35kA at 480Vac and 480Y/277Vac, 18kA at 600Vac and 600Y/347Vac, and 20kA at 250Vdc and 500Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display, and it falls under utilisation category A.
Similar products from: Electronic Components
What can I help you find today?