Schneider Electric LC1D40A6UD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for ring-lugs connections. This 3-pole (3P; 3NO) contactor is designed for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection of IP20 and operates with a control voltage (DC) range of 187.5-312.5Vdc (250Vdc nominal; 0.75...1.25 x Uc). The LC1D40A6UD is rated for a current of 60A (AC-1) and 40A (440Vac; AC-3), with a rated operating voltage (Ue) of up to 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power ranges from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3 category. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 30HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D40A6UD is rated at 6 million operations at no load, and its electrical durability is rated at 1.5 million operations with load. The rated voltage (AC) for phase-to-phase connections is 690 V.

Product Details

  • Product Or Component Type
    Contactor
  • Auxiliary Contact Composition
    1 NO + 1 NC
  • Product Name
    TeSys D
  • [Uc] Control Circuit Voltage
    250 V DC
  • Hold-In Power Consumption In W
    7.4 W 68 °F (20 °C)
  • Maximum Operating Rate
    3600 cyc/h 140 °F (60 °C)
  • Front Cover
    With
  • Coil Technology
    Built-in bidirectional peak limiting diode suppressor
  • Insulation Resistance
    > 10 MOhm signalling circuit
  • Control Circuit Type
    DC standard
  • Power Pole Contact Composition
    3 NO
  • Time Constant
    34 ms
  • Range
    TeSys
  • Rated Breaking Capacity
    800 A 440 V power circuit IEC 60947
  • Signalling Circuit Frequency
    25...400 Hz
  • Mechanical Durability
    10 Mcycles
  • Inrush Power In W
    19 W 68 °F (20 °C))
  • Device Short Name
    LC1D
  • [Uimp] Rated Impulse Withstand Voltage
    6 kV IEC 60947
  • Poles Description
    3P
  • Overvoltage Category
    III
  • Average Impedance
    1.5 mOhm - Ith 60 A 50 Hz power circuit
  • Minimum Switching Voltage
    17 V signalling circuit
  • Minimum Switching Current
    5 mA signalling circuit
  • Mounting Support
    Rail Plate
  • Power Dissipation Per Pole
    2.4 W AC-3 5.4 W AC-1
  • Connections - Terminals
    Control circuit lugs-ring terminals 0.31 in (8 mm)) Power circuit lugs-ring terminals 0.65 in (16.5 mm))
  • Electrical Durability
    0.7 Mcycles 60 A AC-1 <= 440 V 1.5 Mcycles 40 A AC-3 <= 440 V
  • [Ue] Rated Operational Voltage
    Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
  • Contactor Application
    Resistive load Motor control
  • Safety Reliability Level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Non-Overlap Time
    1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
  • [Ith] Conventional Free Air Thermal Current
    10 A 140 °F (60 °C) signalling circuit 60 A 140 °F (60 °C) power circuit
  • [Ie] Rated Operational Current
    60 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit 40 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
  • Operating Time
    42.5...57.5 ms closing 16...24 ms opening
  • Auxiliary Contacts Type
    Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
  • Utilisation Category
    AC-1 AC-4 AC-3
  • Irms Rated Making Capacity
    140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 800 A 440 V power circuit IEC 60947
  • Associated Fuse Rating
    10 A gG signalling circuit IEC 60947-5-1 80 A gG <= 690 V type 1 power circuit 80 A gG <= 690 V type 2 power circuit
  • Control Circuit Voltage Limits
    0.1...0.3 Uc -40…158 °F (-40…70 °C) drop-out DC 0.75...1.25 Uc -40…140 °F (-40…60 °C) operational DC 1...1.25 Uc 140…158 °F (60…70 °C) operational DC
  • Tightening Torque
    Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 53.10 lbf.in (6 N.m) lugs-ring terminals hexagonal 0.39 in (10 mm) M6
  • Product Certifications
    CSA CCC GOST UL
  • Standards
    CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
  • Motor Power Kw
    18.5 kW 380...400 V AC 50/60 Hz AC-3) 11 kW 220...230 V AC 50/60 Hz AC-3) 22 kW 415...440 V AC 50/60 Hz AC-3) 22 kW 500 V AC 50/60 Hz AC-3) 30 kW 660...690 V AC 50/60 Hz AC-3) 9 kW 400 V AC 50/60 Hz AC-4)
  • Motor Power HP (UL / CSA)
    5 hp 230/240 V at AC 50/60 Hz for 1 phase 10 hp 230/240 V at AC 50/60 Hz for 3 phase 30 hp 575/600 V at AC 50/60 Hz for 3 phase 10 hp 200/208 V at AC 50/60 Hz for 3 phase 3 hp 115 V at AC 50/60 Hz for 1 phase 30 hp 460/480 V at AC
  • [Icw] Rated Short-Time Withstand Current
    320 A 104 °F (40 °C) - 10 s power circuit 720 A 104 °F (40 °C) - 1 s power circuit 72 A 104 °F (40 °C) - 10 min power circuit 165 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circ
  • [Ui] Rated Insulation Voltage
    Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 690 V IEC 60947-4-1

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LC1D40A6UD on Powermatic Associates is $369.09. Order now.



Similar products from: Schneider Electric Industrial Automation Components

Manufacturer warranty

LC1D40A6UD Schneider Electric

$369.09

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$369.09

$369.09 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare LC1D40A6UD with other Industrial Automation Components products

Product Or Component Type

Auxiliary Contact Composi...

Product Name

[Uc] Control Circuit Volt...

Hold-In Power Consumption...

Maximum Operating Rate

Front Cover

Coil Technology

Insulation Resistance

Control Circuit Type

Selected product

LC1D40A6UD
Backordered
LC1D40A6UD
Schneider Electric

Schneider Electric LC1D40A6UD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM...

Product Or Component TypeContactor

Auxiliary Contact Composition1 NO + 1 NC

Product NameTeSys D

[Uc] Control Circuit Voltage250 V DC

Hold-In Power Consumption In W7.4 W 68 °F (20 °C)

Maximum Operating Rate3600 cyc/h 140 °F (60 °C)

Front CoverWith

Coil TechnologyBuilt-in bidirectional peak ...

Insulation Resistance> 10 MOhm signalling circuit

Control Circuit TypeDC standard

LC1D40ABD
2 in stock
LC1D40ABD
Schneider Electric

Schneider Electric LC1D40ABD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM)...

Product Or Component TypeContactor

Auxiliary Contact Composition-

Product NameTeSys D

[Uc] Control Circuit Voltage-

Hold-In Power Consumption In W-

Maximum Operating Rate-

Front Cover-

Coil Technology-

Insulation Resistance-

Control Circuit Type-

DFCC2
15 in stock
DFCC2
Schneider Electric

Schneider Electric - DFCC2

Product Or Component TypeFuse carrier

Auxiliary Contact Composition-

Product NameTeSys DF

[Uc] Control Circuit Voltage-

Hold-In Power Consumption In W-

Maximum Operating Rate-

Front Cover-

Coil Technology-

Insulation Resistance-

Control Circuit Type-

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

Recently viewed products

Relevant products

FAQ

What is the price of LC1D40A6UD?
Purchase the LC1D40A6UD from Powermatic Associates at the price of $369.09. Order today.

Out if stock but available for backorder.

Schneider Electric LC1D40A6UD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for ring-lugs connections. This 3-pole (3P; 3NO) contactor is designed for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection of IP20 and operates with a control voltage (DC) range of 187.5-312.5Vdc (250Vdc nominal; 0.75...1.25 x Uc). The LC1D40A6UD is rated for a current of 60A (AC-1) and 40A (440Vac; AC-3), with a rated operating voltage (Ue) of up to 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power ranges from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3 category. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 30HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D40A6UD is rated at 6 million operations at no load, and its electrical durability is rated at 1.5 million operations with load. The rated voltage (AC) for phase-to-phase connections is 690 V.

Similar products from: Industrial Automation Components

What can I help you find today?

Recommended parts