LC1D40AJD Schneider Electric Industrial Automation Components

LC1D40AJD on Powermatic Associates
Schneider Electric

Part#:LC1D40AJD

Manufacturer:Schneider Electric

Category:Industrial Automation Components

Product Lifecycle:Active

Product description

Schneider Electric LC1D40AJD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design with screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 60A for AC-1 and 40A for 440Vac in AC-3. Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection of IP20. The control voltage (DC) ranges from 9-15Vdc, with a nominal 12Vdc, and it operates at a rated operating voltage (Ue) of up to 690 V. It includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 30HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability is rated at 6 million operations at no load, and its electrical durability with load is 1.5 million operations. The rated voltage (AC) for phase-to-phase connections is 690 V.

Product Details

  • Insulation Resistance
    > 10 MOhm signalling circuit
  • Product Or Component Type
    Contactor
  • Poles Description
    3P
  • [Uimp] Rated Impulse Withstand Voltage
    6 kV IEC 60947
  • Signalling Circuit Frequency
    25...400 Hz
  • Range
    TeSys
  • Hold-In Power Consumption In W
    7.4 W 68 °F (20 °C)
  • Product Name
    TeSys D
  • Control Circuit Type
    DC standard
  • Minimum Switching Current
    5 mA signalling circuit
  • [Uc] Control Circuit Voltage
    12 V DC
  • Time Constant
    34 ms
  • Rated Breaking Capacity
    800 A 440 V power circuit IEC 60947
  • Coil Technology
    Built-in bidirectional peak limiting diode suppressor
  • Device Short Name
    LC1D
  • Average Impedance
    1.5 mOhm - Ith 60 A 50 Hz power circuit
  • Inrush Power In W
    19 W 68 °F (20 °C))
  • Front Cover
    With
  • Power Pole Contact Composition
    3 NO
  • Overvoltage Category
    III
  • Maximum Operating Rate
    3600 cyc/h 140 °F (60 °C)
  • Mechanical Durability
    10 Mcycles
  • Auxiliary Contact Composition
    1 NO + 1 NC
  • Minimum Switching Voltage
    17 V signalling circuit
  • Product Certifications
    GOST CSA CCC UL
  • Operating Time
    42.5...57.5 ms closing 16...24 ms opening
  • Contactor Application
    Motor control Resistive load
  • [Ith] Conventional Free Air Thermal Current
    10 A 140 °F (60 °C) signalling circuit 60 A 140 °F (60 °C) power circuit
  • Electrical Durability
    0.7 Mcycles 60 A AC-1 <= 440 V 1.5 Mcycles 40 A AC-3 <= 440 V
  • Mounting Support
    Plate Rail
  • [Ie] Rated Operational Current
    60 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit 40 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
  • [Ue] Rated Operational Voltage
    Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
  • Power Dissipation Per Pole
    2.4 W AC-3 5.4 W AC-1
  • Safety Reliability Level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Auxiliary Contacts Type
    Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
  • Non-Overlap Time
    1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
  • Utilisation Category
    AC-1 AC-3 AC-4
  • Connections - Terminals
    Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)fle
  • Irms Rated Making Capacity
    140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 800 A 440 V power circuit IEC 60947
  • Control Circuit Voltage Limits
    0.1...0.3 Uc -40…158 °F (-40…70 °C) drop-out DC 0.75...1.25 Uc -40…140 °F (-40…60 °C) operational DC 1...1.25 Uc 140…158 °F (60…70 °C) operational DC
  • Tightening Torque
    Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 70.81 lbf.in (8 N.m) EverLink BTR screw connectors 0.04…0.05 in² (25…35 mm²) hexagon
  • Associated Fuse Rating
    10 A gG signalling circuit IEC 60947-5-1 80 A gG <= 690 V type 1 power circuit 80 A gG <= 690 V type 2 power circuit
  • Motor Power HP (UL / CSA)
    5 hp 230/240 V at AC 50/60 Hz for 1 phase 10 hp 230/240 V at AC 50/60 Hz for 3 phase 30 hp 575/600 V at AC 50/60 Hz for 3 phase 10 hp 200/208 V at AC 50/60 Hz for 3 phase 3 hp 115 V at AC 50/60 Hz for 1 phase 30 hp 460/480 V at AC
  • Motor Power Kw
    18.5 kW 380...400 V AC 50/60 Hz AC-3) 11 kW 220...230 V AC 50/60 Hz AC-3) 22 kW 415...440 V AC 50/60 Hz AC-3) 22 kW 500 V AC 50/60 Hz AC-3) 30 kW 660...690 V AC 50/60 Hz AC-3) 9 kW 400 V AC 50/60 Hz AC-4)
  • [Icw] Rated Short-Time Withstand Current
    320 A 104 °F (40 °C) - 10 s power circuit 720 A 104 °F (40 °C) - 1 s power circuit 72 A 104 °F (40 °C) - 10 min power circuit 165 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circ
  • Standards
    CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
  • [Ui] Rated Insulation Voltage
    Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 690 V IEC 60947-4-1

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LC1D40AJD on Powermatic Associates is $326.32. Order now.



Similar products from: Schneider Electric Industrial Automation Components

Manufacturer warranty

LC1D40AJD Schneider Electric

$326.32

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$326.32

$326.32 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare LC1D40AJD with other Industrial Automation Components products

Insulation Resistance

Product Or Component Type

Poles Description

[Uimp] Rated Impulse With...

Signalling Circuit Freque...

Range

Hold-In Power Consumption...

Product Name

Control Circuit Type

Minimum Switching Current

Selected product

LC1D40AJD
Backordered
LC1D40AJD
Schneider Electric

Schneider Electric LC1D40AJD is a magnetic contactor from the Deca sub-range, featuring an EverLink(...

Insulation Resistance> 10 MOhm signalling circuit

Product Or Component TypeContactor

Poles Description3P

[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947

Signalling Circuit Frequency25...400 Hz

RangeTeSys

Hold-In Power Consumption In W7.4 W 68 °F (20 °C)

Product NameTeSys D

Control Circuit TypeDC standard

Minimum Switching Current5 mA signalling circuit

LC1D40ABD
2 in stock
LC1D40ABD
Schneider Electric

Schneider Electric LC1D40ABD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM)...

Insulation Resistance-

Product Or Component TypeContactor

Poles Description3P

[Uimp] Rated Impulse Withstand Voltage-

Signalling Circuit Frequency-

RangeTeSys

Hold-In Power Consumption In W-

Product NameTeSys D

Control Circuit Type-

Minimum Switching Current-

LC1D50A6BD
2 in stock
LC1D50A6BD
Schneider Electric

Schneider Electric LC1D50A6BD is a magnetic contactor from the Deca sub-range, featuring an EverLink...

Insulation Resistance-

Product Or Component TypeContactor

Poles Description3P

[Uimp] Rated Impulse Withstand Voltage-

Signalling Circuit Frequency-

RangeTeSys

Hold-In Power Consumption In W-

Product NameTeSys D

Control Circuit Type-

Minimum Switching Current-

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

Recently viewed products

Relevant products

FAQ

What is the price of LC1D40AJD?
Purchase the LC1D40AJD from Powermatic Associates at the price of $326.32. Order today.

Out if stock but available for backorder.

Schneider Electric LC1D40AJD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design with screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 60A for AC-1 and 40A for 440Vac in AC-3. Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection of IP20. The control voltage (DC) ranges from 9-15Vdc, with a nominal 12Vdc, and it operates at a rated operating voltage (Ue) of up to 690 V. It includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 30HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability is rated at 6 million operations at no load, and its electrical durability with load is 1.5 million operations. The rated voltage (AC) for phase-to-phase connections is 690 V.

Similar products from: Industrial Automation Components

What can I help you find today?

Recommended parts