Product description
Schneider Electric LC1D50A6FD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminals and ring-lugs connections. This 3-pole (3P; 3NO) contactor supports a rated current of 80A under AC-1 conditions and 50A at 440Vac under AC-3 conditions. It is designed for DIN rail mounting, with a net width of 55 mm and an IP20 degree of protection. The control voltage (DC) ranges from 82.5-137.5Vdc (110Vdc nominal; 0.75...1.25 x Uc), and the rated operating voltage (Ue) is up to 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, with a contacts type of 1NO+1NC instantaneous aux. The rated impulse voltage (Uimp) is 6 kV. Rated active power spans from 15kW at 220-230Vac to 33kW at 660-690Vac under AC-3 conditions. Rated power in horsepower (HP) ranges from 3HP at 115Vac to 40HP at 575-600Vac, with specific ratings for single-phase and 3-phase connections under UL/CSA standards. Mechanical durability is rated at 6,000,000 operations, and electrical durability at 1,450,000 operations with load. The rated voltage (AC) phase-to-phase is 690 V.
Product Details
- Product Name TeSys D
- Auxiliary Contact Composition 1 NO + 1 NC
- Product Or Component Type Contactor
- Inrush Power In W 19 W 68 °F (20 °C))
- Overvoltage Category III
- [Uc] Control Circuit Voltage 110 V DC
- Average Impedance 1.5 mOhm - Ith 80 A 50 Hz power circuit
- [Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947
- Poles Description 3P
- Power Pole Contact Composition 3 NO
- Device Short Name LC1D
- Range TeSys
- Control Circuit Type DC standard
- Front Cover With
- Coil Technology Built-in bidirectional peak limiting diode suppressor
- Rated Breaking Capacity 900 A 440 V power circuit IEC 60947
- Minimum Switching Voltage 17 V signalling circuit
- Time Constant 34 ms
- Signalling Circuit Frequency 25...400 Hz
- Minimum Switching Current 5 mA signalling circuit
- Hold-In Power Consumption In W 7.4 W 68 °F (20 °C)
- Mechanical Durability 10 Mcycles
- Maximum Operating Rate 3600 cyc/h 140 °F (60 °C)
- Insulation Resistance > 10 MOhm for signalling circuit
- [Ue] Rated Operational Voltage Power circuit: <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
- [Ie] Rated Operational Current 50 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit 80 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
- Mounting Support Plate Rail
- [Ith] Conventional Free Air Thermal Current 10 A 140 °F (60 °C) signalling circuit 80 A 140 °F (60 °C) power circuit
- Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
- Contactor Application Motor control Resistive load
- Connections - Terminals Control circuit lugs-ring terminals 0.31 in (8 mm)) Power circuit lugs-ring terminals 0.65 in (16.5 mm))
- Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
- Power Dissipation Per Pole 3.7 W AC-3 9.6 W AC-1
- Electrical Durability 1.45 Mcycles 50 A AC-3 <= 440 V 0.5 Mcycles 80 A AC-1 <= 440 V
- Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Operating Time 42.5...57.5 ms closing 16...24 ms opening
- Tightening Torque Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 53.10 lbf.in (6 N.m) lugs-ring terminals hexagonal 0.39 in (10 mm) M6
- Utilisation Category AC-1 AC-4 AC-3
- Irms Rated Making Capacity 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 900 A 440 V power circuit IEC 60947
- Control Circuit Voltage Limits 0.1...0.3 Uc -40…158 °F (-40…70 °C) drop-out DC 0.75...1.25 Uc -40…140 °F (-40…60 °C) operational DC 1...1.25 Uc 140…158 °F (60…70 °C) operational DC
- Associated Fuse Rating 10 A gG signalling circuit IEC 60947-5-1 100 A gG <= 690 V type 1 power circuit 100 A gG <= 690 V type 2 power circuit
- Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
- Motor Power HP (UL / CSA) 3 hp 115 V at AC 50/60 Hz for 1 phase 7.5 hp 230/240 V at AC 50/60 Hz for 1 phase 15 hp 200/208 V at AC 50/60 Hz for 3 phase 15 hp 230/240 V at AC 50/60 Hz for 3 phase 40 hp 460/480 V at AC 50/60 Hz for 3 phase 40 hp 575/600 V at
- [Icw] Rated Short-Time Withstand Current 400 A 104 °F (40 °C) - 10 s power circuit 810 A 104 °F (40 °C) - 1 s power circuit 84 A 104 °F (40 °C) - 10 min power circuit 208 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circ
- [Ui] Rated Insulation Voltage Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 690 V IEC 60947-4-1
- Motor Power Kw 15 kW 220...230 V AC 50/60 Hz AC-3) 22 kW 380...400 V AC 50/60 Hz AC-3) 30 kW 500 V AC 50/60 Hz AC-3) 33 kW 660...690 V AC 50/60 Hz AC-3) 25 kW 415 V AC 50/60 Hz AC-3) 30 kW 440 V AC 50/60 Hz AC-3) 11 kW 400 V AC 50/60 Hz AC-
- Product Certifications CSA RINA LROS (Lloyds register of shipping) UL GL GOST BV CCC DNV
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LC1D50A6FD on Powermatic Associates is $396.11. Order now.
LC1D50A6FD Related Documents
Similar products from: Schneider Electric Industrial Automation Components
Manufacturer warranty
LC1D50A6FD Schneider Electric
$396.11
Your price can be lower.
Log in or Create account to check your discount
Select Qty:
$396.11
$396.11 each
Average response time: 11 minutes
Worldwide Shipping and Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare LC1D50A6FD with other Industrial Automation Components products
Product Name
Auxiliary Contact Composi...
Product Or Component Type
Inrush Power In W
Overvoltage Category
[Uc] Control Circuit Volt...
Average Impedance
[Uimp] Rated Impulse With...
Poles Description
Power Pole Contact Compos...
Selected product

LC1D50A6FD
Schneider Electric
Schneider Electric LC1D50A6FD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM...
Product NameTeSys D
Auxiliary Contact Composition1 NO + 1 NC
Product Or Component TypeContactor
Inrush Power In W19 W 68 °F (20 °C))
Overvoltage CategoryIII
[Uc] Control Circuit Voltage110 V DC
Average Impedance1.5 mOhm - Ith 80 A 50 Hz po...
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947
Poles Description3P
Power Pole Contact Composition3 NO
About the manufacturer
Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...
Recently viewed products
Relevant products
FAQ
What is the price of LC1D50A6FD?
Purchase the LC1D50A6FD from Powermatic Associates at the price of $396.11. Order today.
Out if stock but available for backorder.
Schneider Electric LC1D50A6FD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminals and ring-lugs connections. This 3-pole (3P; 3NO) contactor supports a rated current of 80A under AC-1 conditions and 50A at 440Vac under AC-3 conditions. It is designed for DIN rail mounting, with a net width of 55 mm and an IP20 degree of protection. The control voltage (DC) ranges from 82.5-137.5Vdc (110Vdc nominal; 0.75...1.25 x Uc), and the rated operating voltage (Ue) is up to 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, with a contacts type of 1NO+1NC instantaneous aux. The rated impulse voltage (Uimp) is 6 kV. Rated active power spans from 15kW at 220-230Vac to 33kW at 660-690Vac under AC-3 conditions. Rated power in horsepower (HP) ranges from 3HP at 115Vac to 40HP at 575-600Vac, with specific ratings for single-phase and 3-phase connections under UL/CSA standards. Mechanical durability is rated at 6,000,000 operations, and electrical durability at 1,450,000 operations with load. The rated voltage (AC) phase-to-phase is 690 V.
Similar products from: Industrial Automation Components
What can I help you find today?