LC1D50AX7 Schneider Electric Industrial Automation Components

LC1D50AX7 on Powermatic Associates
Schneider Electric

Part#:LC1D50AX7

Manufacturer:Schneider Electric

Category:Industrial Automation Components

Product Lifecycle:Active

Product description

Schneider Electric LC1D50AX7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 80A for AC-1 and 50A for 440Vac in AC-3. Designed for DIN rail mounting, it has a net width of 55 mm and offers an IP20 degree of protection. The control voltage ranges from 480-660Vac at 50Hz and 510-660Vac at 60Hz, with a nominal control voltage of 600Vac. The rated operating voltage (Ue) is 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 15kW at 220-230Vac to 33kW at 660-690Vac in AC-3. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 40HP at 575-600Vac in three-phase, under UL/CSA standards. This contactor is built for mechanical durability of 6,000,000 operations and electrical durability of 1,450,000 operations with load, with a phase-to-phase rated voltage of 690 V.

Product Details

  • Product Certifications
    GL GOST UL DNV LROS (Lloyds register of shipping) RINA CCC CSA BV
  • Motor Power Kw
    15 kW 220...230 V AC 50/60 Hz AC-3) 22 kW 380...400 V AC 50/60 Hz AC-3) 30 kW 500 V AC 50/60 Hz AC-3) 33 kW 660...690 V AC 50/60 Hz AC-3) 25 kW 415 V AC 50/60 Hz AC-3) 30 kW 440 V AC 50/60 Hz AC-3) 11 kW 400 V AC 50/60 Hz AC-
  • [Icw] Rated Short-Time Withstand Current
    400 A 104 °F (40 °C) - 10 s power circuit 810 A 104 °F (40 °C) - 1 s power circuit 84 A 104 °F (40 °C) - 10 min power circuit 208 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circ
  • Motor Power HP (UL / CSA)
    3 hp 115 V at AC 50/60 Hz for 1 phase 7.5 hp 230/240 V at AC 50/60 Hz for 1 phase 15 hp 200/208 V at AC 50/60 Hz for 3 phase 15 hp 230/240 V at AC 50/60 Hz for 3 phase 40 hp 460/480 V at AC 50/60 Hz for 3 phase 40 hp 575/600 V at
  • [Ui] Rated Insulation Voltage
    Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 690 V IEC 60947-4-1
  • Standards
    CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
  • Control Circuit Voltage Limits
    0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
  • Connections - Terminals
    Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)fle
  • Irms Rated Making Capacity
    140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 900 A 440 V power circuit IEC 60947
  • Tightening Torque
    Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 70.81 lbf.in (8 N.m) EverLink BTR screw connectors 0.04…0.05 in² (25…35 mm²) hexagon
  • Associated Fuse Rating
    10 A gG signalling circuit IEC 60947-5-1 100 A gG <= 690 V type 1 power circuit 100 A gG <= 690 V type 2 power circuit
  • Utilisation Category
    AC-1 AC-3 AC-4
  • Non-Overlap Time
    1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
  • Hold-In Power Consumption In VA
    13 VA 60 Hz 0.3 68 °F (20 °C)) 15 VA 50 Hz 0.3 68 °F (20 °C))
  • [Ith] Conventional Free Air Thermal Current
    10 A 140 °F (60 °C) signalling circuit 80 A 140 °F (60 °C) power circuit
  • Contactor Application
    Resistive load Motor control
  • Inrush Power In VA
    140 VA 60 Hz 0.75 68 °F (20 °C)) 160 VA 50 Hz 0.75 68 °F (20 °C))
  • Operating Time
    4...19 ms opening 12...26 ms closing
  • Safety Reliability Level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Power Dissipation Per Pole
    3.7 W AC-3 9.6 W AC-1
  • Auxiliary Contacts Type
    Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
  • Electrical Durability
    1.45 Mcycles 50 A AC-3 <= 440 V 1.1 Mcycles 80 A AC-1 <= 440 V
  • [Ie] Rated Operational Current
    50 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit 80 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
  • [Ue] Rated Operational Voltage
    Power circuit: <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
  • Mounting Support
    Rail Plate
  • Insulation Resistance
    > 10 MOhm for signalling circuit
  • Minimum Switching Voltage
    17 V signalling circuit
  • Signalling Circuit Frequency
    25...400 Hz
  • Heat Dissipation
    4…5 W 50/60 Hz
  • Coil Technology
    Without built-in suppressor module
  • Minimum Switching Current
    5 mA signalling circuit
  • Maximum Operating Rate
    3600 cyc/h 140 °F (60 °C)
  • Mechanical Durability
    6 Mcycles
  • Front Cover
    With
  • Rated Breaking Capacity
    900 A 440 V power circuit IEC 60947
  • [Uimp] Rated Impulse Withstand Voltage
    6 kV IEC 60947
  • Average Impedance
    1.5 mOhm - Ith 80 A 50 Hz power circuit
  • Overvoltage Category
    III
  • Auxiliary Contact Composition
    1 NO + 1 NC
  • [Uc] Control Circuit Voltage
    600 V AC 50/60 Hz
  • Control Circuit Type
    AC at 50/60 Hz
  • Power Pole Contact Composition
    3 NO
  • Poles Description
    3P
  • Device Short Name
    LC1D
  • Product Or Component Type
    Contactor
  • Product Name
    TeSys D
  • Range
    TeSys

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LC1D50AX7 on Powermatic Associates is $290.95. Order now.



Similar products from: Schneider Electric Industrial Automation Components

Manufacturer warranty

LC1D50AX7 Schneider Electric

$290.95

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$290.95

$290.95 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare LC1D50AX7 with other Industrial Automation Components products

Product Certifications

Motor Power Kw

[Icw] Rated Short-Time Wi...

Motor Power HP (UL / CSA)

[Ui] Rated Insulation Vol...

Standards

Control Circuit Voltage L...

Connections - Terminals

Irms Rated Making Capacit...

Tightening Torque

Selected product

LC1D50AX7
Backordered
LC1D50AX7
Schneider Electric

Schneider Electric LC1D50AX7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM)...

Product CertificationsGL GOST UL DNV LROS (Lloyds ...

Motor Power Kw15 kW 220...230 V AC 50/60 H...

[Icw] Rated Short-Time Withstand Current400 A 104 °F (40 °C) - 10 s ...

Motor Power HP (UL / CSA)3 hp 115 V at AC 50/60 Hz fo...

[Ui] Rated Insulation VoltagePower circuit 600 V CSA Powe...

StandardsCSA C22.2 No 14 EN 60947-4-1...

Control Circuit Voltage Limits0.3...0.6 Uc -40…158 °F (-40...

Connections - TerminalsControl circuit screw clamp ...

Irms Rated Making Capacity140 A AC signalling circuit ...

Tightening TorqueControl circuit 15.05 lbf.in...

LC1D40ABD
2 in stock
LC1D40ABD
Schneider Electric

Schneider Electric LC1D40ABD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM)...

Product Certifications-

Motor Power Kw18.5 kW 380...400 V AC 50/60...

[Icw] Rated Short-Time Withstand Current-

Motor Power HP (UL / CSA)5 hp 230/240 V at AC 50/60 H...

[Ui] Rated Insulation Voltage-

Standards-

Control Circuit Voltage Limits-

Connections - Terminals-

Irms Rated Making Capacity-

Tightening Torque-

LC1D326BL
4 in stock
LC1D326BL
Schneider Electric

Schneider Electric LC1D326BL is a magnetic contactor from the Deca sub-range, featuring a low-consum...

Product Certifications-

Motor Power Kw7.5 kW 220...230 V AC 50/60 ...

[Icw] Rated Short-Time Withstand Current-

Motor Power HP (UL / CSA)2 hp 115 V at AC 50/60 Hz fo...

[Ui] Rated Insulation Voltage-

Standards-

Control Circuit Voltage Limits-

Connections - Terminals-

Irms Rated Making Capacity-

Tightening Torque-

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

Recently viewed products

Relevant products

FAQ

What is the price of LC1D50AX7?
Purchase the LC1D50AX7 from Powermatic Associates at the price of $290.95. Order today.

Out if stock but available for backorder.

Schneider Electric LC1D50AX7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 80A for AC-1 and 50A for 440Vac in AC-3. Designed for DIN rail mounting, it has a net width of 55 mm and offers an IP20 degree of protection. The control voltage ranges from 480-660Vac at 50Hz and 510-660Vac at 60Hz, with a nominal control voltage of 600Vac. The rated operating voltage (Ue) is 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 15kW at 220-230Vac to 33kW at 660-690Vac in AC-3. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 40HP at 575-600Vac in three-phase, under UL/CSA standards. This contactor is built for mechanical durability of 6,000,000 operations and electrical durability of 1,450,000 operations with load, with a phase-to-phase rated voltage of 690 V.

Similar products from: Industrial Automation Components

What can I help you find today?

Recommended parts