Square D by Schneider Electric BGF46040 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGF sub-range, featuring a PowerPact B-Frame 100 TMD 4P-4t design. It has a rated current of 40A and operates at a rated voltage of 600Vac 600Y/347Vac, with a rated impulse voltage (Uimp) of 8 kV. The connection type is a terminal nut kit for fixed busbar connection on both line and load sides, and it offers a degree of protection of IP40. This MCCB is designed for fixed mounting on DIN rail or as an individual unit mount on a plate, with 4 poles (4P) and dimensions of 137 mm in height, 80 mm in depth, and 108 mm in width. It falls under utilisation category A and features over-current protection fixed at 40A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated insulation voltage (Ui) is 800 V, with a rated operating voltage (Ue) of 525 V, and it includes thermal and magnetic protection functions. The trip current rating is 40 AT, with a frame current rating of 100 AF. It operates manually via a toggle and has a short circuit breaking rating of 65kA at 240Vac, 35kA at 480Vac, 35kA at 480Y/277Vac, 18kA at 600Y/347Vac, and 20kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display.
Product Details
- Breaking Capacity 65 kA 208Y/120 V AC 50/60 Hz UL 489 65 kA 240 V AC 50/60 Hz UL 489 35 kA 480/277 V AC 50/60 Hz UL 489 35 kA 480 V AC 50/60 Hz UL 489 20 kA 250 V DC UL 489 18 kA 600Y/347 V AC 50/60 Hz UL 489
- [Ics] Rated Service Breaking Capacity 65 kA 220...240 V AC 50/60 Hz IEC 60947-2 18 kA 500...525 V AC 50/60 Hz IEC 60947-2 35 kA 380...415 V AC 50/60 Hz IEC 60947-2 35 kA 440 V AC 50/60 Hz IEC 60947-2
- Number Of Slots 1 auxiliary switch OF plug-in) 1 voltage release MN or MX plug-in) 1 alarm switch SD plug-in)
- Tightening Torque 44.25 lbf.in (5 N.m) 0.00…0.02 in² (2.5…16 mm²) (AWG 14...AWG 4) 79.66 lbf.in (9 N.m) 0.04…0.15 in² (25…95 mm²) (AWG 3...AWG 3/0)
- Mounting Mode Clip-on 35 mm symmetrical DIN rail) By screws plate)
- AWG Gauge AWG 14...AWG 8 aluminium/copper AWG 6...AWG 3/0 aluminium/copper
- Local Signalling for presence of auxiliary contacts flag (green)
- Quantity Per Set Set of 1
- Net Weight 2.74 lb(US) (1.241 kg)
- Depth 3.15 in (80 mm)
- 9 Mm Pitches 12
- Color Grey (RAL 7016)
- Power Wire Stripping Length 0.79 in (20 mm)
- Width 4.25 in (108 mm)
- Height 5.39 in (137 mm)
- Connection Pitch 1.06 in (27 mm)
- Electrical Connection Terminal nut ON and OFF end
- Trip Unit Name TM-D
- Electrical Durability 10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
- Mechanical Durability 15000 cycles IEC 947-1 Annex K ed 5.2
- [Ui] Rated Insulation Voltage 800 V IEC 60947-2
- Utilisation Category Category A
- Continuous Current Rating 80 %
- Suitability For Isolation Yes IEC 60947-2
- [Uimp] Rated Impulse Withstand Voltage 8 kV IEC 60947-2
- Trip Unit Technology Thermal-magnetic
- [Ue] Rated Operational Voltage 525 V AC 50/60 Hz UL 489
- Breaking Capacity Code G
- Device Application Distribution
- Protected Poles Description 4t
- Control Type Toggle
- Number Of Poles 4P
- Line Rated Current 40 A
- Range PowerPact
- Product Or Component Type Circuit breaker
- Product Name PowerPact B
- Device Short Name BG 040
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
BGF46040 Related Documents
Similar products from: Schneider Electric Electronic Components
Manufacturer warranty
BGF46040 Schneider Electric
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Worldwide Shipping and Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare BGF46040 with other Electronic Components products
Breaking Capacity
[Ics] Rated Service Break...
Number Of Slots
Tightening Torque
Mounting Mode
AWG Gauge
Local Signalling
Quantity Per Set
Net Weight
Depth
Selected product

BGF46040
Schneider Electric
Square D by Schneider Electric BGF46040 is a Moulded Case Circuit Breaker (MCCB) within the PowerPac...
Breaking Capacity65 kA 208Y/120 V AC 50/60 Hz...
[Ics] Rated Service Breaking Capacity65 kA 220...240 V AC 50/60 H...
Number Of Slots1 auxiliary switch OF plug-i...
Tightening Torque44.25 lbf.in (5 N.m) 0.00…0....
Mounting ModeClip-on 35 mm symmetrical DI...
AWG GaugeAWG 14...AWG 8 aluminium/cop...
Local Signallingfor presence of auxiliary co...
Quantity Per SetSet of 1
Net Weight2.74 lb(US) (1.241 kg)
Depth3.15 in (80 mm)
About the manufacturer
Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...
Recently viewed products
Relevant products
FAQ
Out if stock but available for backorder.
Square D by Schneider Electric BGF46040 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGF sub-range, featuring a PowerPact B-Frame 100 TMD 4P-4t design. It has a rated current of 40A and operates at a rated voltage of 600Vac 600Y/347Vac, with a rated impulse voltage (Uimp) of 8 kV. The connection type is a terminal nut kit for fixed busbar connection on both line and load sides, and it offers a degree of protection of IP40. This MCCB is designed for fixed mounting on DIN rail or as an individual unit mount on a plate, with 4 poles (4P) and dimensions of 137 mm in height, 80 mm in depth, and 108 mm in width. It falls under utilisation category A and features over-current protection fixed at 40A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated insulation voltage (Ui) is 800 V, with a rated operating voltage (Ue) of 525 V, and it includes thermal and magnetic protection functions. The trip current rating is 40 AT, with a frame current rating of 100 AF. It operates manually via a toggle and has a short circuit breaking rating of 65kA at 240Vac, 35kA at 480Vac, 35kA at 480Y/277Vac, 18kA at 600Y/347Vac, and 20kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display.
Similar products from: Electronic Components
What can I help you find today?