Product description

Schneider Electric LC1D40A6FD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design for ring-lugs connections. This 3-pole (3P; 3NO) contactor is designed for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection of IP20 and operates with a control voltage (DC) range of 82.5-137.5Vdc (110Vdc nominal; 0.75...1.25 x Uc). The LC1D40A6FD is rated for a current of 60A (AC-1) and 40A (440Vac; AC-3), with a rated operating voltage (Ue) of 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power ranges from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3 category. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 30HP at 575-600Vac in three-phase, according to UL/CSA standards. The mechanical durability of the LC1D40A6FD is rated at 6,000,000 operations, and its electrical durability with load is 1,500,000 operations. The rated voltage (AC) for phase-to-phase connections is 690 V.

Product Details

  • [Icw] Rated Short-Time Withstand Current
    320 A 104 °F (40 °C) - 10 s power circuit 720 A 104 °F (40 °C) - 1 s power circuit 72 A 104 °F (40 °C) - 10 min power circuit 165 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circ
  • Motor Power HP (UL / CSA)
    5 hp 230/240 V at AC 50/60 Hz for 1 phase 10 hp 230/240 V at AC 50/60 Hz for 3 phase 30 hp 575/600 V at AC 50/60 Hz for 3 phase 10 hp 200/208 V at AC 50/60 Hz for 3 phase 3 hp 115 V at AC 50/60 Hz for 1 phase 30 hp 460/480 V at AC
  • Standards
    CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
  • Motor Power Kw
    18.5 kW 380...400 V AC 50/60 Hz AC-3) 11 kW 220...230 V AC 50/60 Hz AC-3) 22 kW 415...440 V AC 50/60 Hz AC-3) 22 kW 500 V AC 50/60 Hz AC-3) 30 kW 660...690 V AC 50/60 Hz AC-3) 9 kW 400 V AC 50/60 Hz AC-4)
  • Product Certifications
    UL CSA CCC GOST
  • Control Circuit Voltage Limits
    0.1...0.3 Uc -40…158 °F (-40…70 °C) drop-out DC 0.75...1.25 Uc -40…140 °F (-40…60 °C) operational DC 1...1.25 Uc 140…158 °F (60…70 °C) operational DC
  • Irms Rated Making Capacity
    140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 800 A 440 V power circuit IEC 60947
  • Utilisation Category
    AC-3 AC-1 AC-4
  • Associated Fuse Rating
    10 A gG signalling circuit IEC 60947-5-1 80 A gG <= 690 V type 1 power circuit 80 A gG <= 690 V type 2 power circuit
  • Tightening Torque
    Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 53.10 lbf.in (6 N.m) lugs-ring terminals hexagonal 0.39 in (10 mm) M6
  • Safety Reliability Level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • [Ith] Conventional Free Air Thermal Current
    10 A 140 °F (60 °C) signalling circuit 60 A 140 °F (60 °C) power circuit
  • Connections - Terminals
    Control circuit lugs-ring terminals 0.31 in (8 mm)) Power circuit lugs-ring terminals 0.65 in (16.5 mm))
  • Operating Time
    42.5...57.5 ms closing 16...24 ms opening
  • [Ue] Rated Operational Voltage
    Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
  • Contactor Application
    Motor control Resistive load
  • [Ie] Rated Operational Current
    60 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit 40 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
  • Non-Overlap Time
    1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
  • Mounting Support
    Plate Rail
  • Auxiliary Contacts Type
    Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
  • Electrical Durability
    0.7 Mcycles 60 A AC-1 <= 440 V 1.5 Mcycles 40 A AC-3 <= 440 V
  • Power Dissipation Per Pole
    2.4 W AC-3 5.4 W AC-1
  • [Ui] Rated Insulation Voltage
    Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 690 V IEC 60947-4-1
  • Minimum Switching Voltage
    17 V signalling circuit
  • Signalling Circuit Frequency
    25...400 Hz
  • Hold-In Power Consumption In W
    7.4 W 68 °F (20 °C)
  • Time Constant
    34 ms
  • Inrush Power In W
    19 W 68 °F (20 °C))
  • Maximum Operating Rate
    3600 cyc/h 140 °F (60 °C)
  • Insulation Resistance
    > 10 MOhm signalling circuit
  • Minimum Switching Current
    5 mA signalling circuit
  • Coil Technology
    Built-in bidirectional peak limiting diode suppressor
  • Mechanical Durability
    10 Mcycles
  • Average Impedance
    1.5 mOhm - Ith 60 A 50 Hz power circuit
  • Front Cover
    With
  • Rated Breaking Capacity
    800 A 440 V power circuit IEC 60947
  • Overvoltage Category
    III
  • [Uc] Control Circuit Voltage
    110 V DC
  • Auxiliary Contact Composition
    1 NO + 1 NC
  • [Uimp] Rated Impulse Withstand Voltage
    6 kV IEC 60947
  • Control Circuit Type
    DC standard
  • Range
    TeSys
  • Poles Description
    3P
  • Device Short Name
    LC1D
  • Power Pole Contact Composition
    3 NO
  • Product Or Component Type
    Contactor
  • Product Name
    TeSys D

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LC1D40A6FD on Powermatic Associates is $351.72. Order now.



Similar products from: Schneider Electric Industrial Automation Components

Manufacturer warranty

LC1D40A6FD Schneider Electric

$351.72

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$351.72

$351.72 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare LC1D40A6FD with other Industrial Automation Components products

[Icw] Rated Short-Time Wi...

Motor Power HP (UL / CSA)

Standards

Motor Power Kw

Product Certifications

Control Circuit Voltage L...

Irms Rated Making Capacit...

Utilisation Category

Associated Fuse Rating

Tightening Torque

Selected product

LC1D40A6FD
Backordered
LC1D40A6FD
Schneider Electric

Schneider Electric LC1D40A6FD is a magnetic contactor from the Deca sub-range, featuring an EverLink...

[Icw] Rated Short-Time Withstand Current320 A 104 °F (40 °C) - 10 s ...

Motor Power HP (UL / CSA)5 hp 230/240 V at AC 50/60 H...

StandardsCSA C22.2 No 14 EN 60947-4-1...

Motor Power Kw18.5 kW 380...400 V AC 50/60...

Product CertificationsUL CSA CCC GOST

Control Circuit Voltage Limits0.1...0.3 Uc -40…158 °F (-40...

Irms Rated Making Capacity140 A AC signalling circuit ...

Utilisation CategoryAC-3 AC-1 AC-4

Associated Fuse Rating10 A gG signalling circuit I...

Tightening TorqueControl circuit 15.05 lbf.in...

LC1D256BD
41 in stock
LC1D256BD
Schneider Electric

Schneider Electric LC1D256BD is a magnetic contactor from the Deca sub-range, designed for ring-lugs...

[Icw] Rated Short-Time Withstand Current-

Motor Power HP (UL / CSA)-

Standards-

Motor Power Kw5.5 kW 220...230 V AC 50/60 ...

Product Certifications-

Control Circuit Voltage Limits-

Irms Rated Making Capacity-

Utilisation CategoryAC-3 AC-1 AC-4

Associated Fuse Rating-

Tightening Torque-

LC1D40ABD
2 in stock
LC1D40ABD
Schneider Electric

Schneider Electric LC1D40ABD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM)...

[Icw] Rated Short-Time Withstand Current-

Motor Power HP (UL / CSA)-

Standards-

Motor Power Kw18.5 kW 380...400 V AC 50/60...

Product Certifications-

Control Circuit Voltage Limits-

Irms Rated Making Capacity-

Utilisation CategoryAC-1 AC-3 AC-4

Associated Fuse Rating-

Tightening Torque-

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

Recently viewed products

Relevant products

FAQ

What is the price of LC1D40A6FD?
Purchase the LC1D40A6FD from Powermatic Associates at the price of $351.72. Order today.

Out if stock but available for backorder.

Schneider Electric LC1D40A6FD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design for ring-lugs connections. This 3-pole (3P; 3NO) contactor is designed for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection of IP20 and operates with a control voltage (DC) range of 82.5-137.5Vdc (110Vdc nominal; 0.75...1.25 x Uc). The LC1D40A6FD is rated for a current of 60A (AC-1) and 40A (440Vac; AC-3), with a rated operating voltage (Ue) of 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power ranges from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3 category. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 30HP at 575-600Vac in three-phase, according to UL/CSA standards. The mechanical durability of the LC1D40A6FD is rated at 6,000,000 operations, and its electrical durability with load is 1,500,000 operations. The rated voltage (AC) for phase-to-phase connections is 690 V.

Similar products from: Industrial Automation Components

What can I help you find today?

Recommended parts