Product description

Schneider Electric - BJA360506

Product Details

  • Device Short Name
    BJ 050
  • Line Rated Current
    50 A
  • Control Type
    Toggle
  • Trip Unit Technology
    Thermal-magnetic
  • Electrical Durability
    10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
  • Depth
    3.50 in (89 mm)
  • Number Of Poles
    3P
  • [Ui] Rated Insulation Voltage
    800 V IEC 60947-2
  • Connection Pitch
    1.06 in (27 mm)
  • [Ue] Rated Operational Voltage
    690 V AC 50/60 Hz UL 489
  • Device Application
    Distribution
  • Continuous Current Rating
    80 %
  • Breaking Capacity Code
    J
  • Product Name
    PowerPact B
  • Utilisation Category
    Category A
  • Local Signalling
    for presence of auxiliary contacts flag (green)
  • Color
    Grey (RAL 7016)
  • Product Or Component Type
    Circuit breaker
  • Suitability For Isolation
    Yes IEC 60947-2
  • Mounting Height
    4.49 in (114 mm)
  • Mechanical Durability
    20000 cycles IEC 947-1 Annex K ed 5.2
  • Width
    3.19 in (81 mm)
  • Range
    PowerPact
  • [Uimp] Rated Impulse Withstand Voltage
    8 kV IEC 60947-2
  • Mounting Mode
    I-Line
  • Height
    5.39 in (137 mm)
  • Phase Connection
    CBA
  • 9 Mm Pitches
    9
  • AWG Gauge
    AWG 14...AWG 2/0 aluminium/copper
  • Power Wire Stripping Length
    0.79 in (20 mm)
  • Net Weight
    2.90 lb(US) (1.315 kg)
  • Quantity Per Set
    Set of 1
  • Tightening Torque
    31.86…38.94 lbf.in (3.6…4.4 N.m) 0.00…0.01 in² (2.5…6 mm²) (AWG 14...AWG 10) 44.25…54.87 lbf.in (5…6.2 N.m) 0.02…0.11 in² (10…70 mm²) (AWG 8...AWG 2/0)
  • Electrical Connection
    I-Line connection line Lugs load
  • Number Of Slots
    1 auxiliary switch OF plug-in) 1 voltage release MN or MX plug-in) 1 alarm switch SD plug-in)
  • [Ics] Rated Service Breaking Capacity
    100 kA 220...240 V AC 50/60 Hz IEC 60947-2 25 kA 500...525 V AC 50/60 Hz IEC 60947-2 2.5 kA 690 V AC 50/60 Hz IEC 60947-2 65 kA 380...415 V AC 50/60 Hz IEC 60947-2 65 kA 440 V AC 50/60 Hz IEC 60947-2
  • Breaking Capacity
    100 kA 208Y/120 V AC 50/60 Hz UL 489 100 kA 240 V AC 50/60 Hz UL 489 65 kA 480/277 V AC 50/60 Hz UL 489 65 kA 480 V AC 50/60 Hz UL 489 25 kA 600Y/347 V AC 50/60 Hz UL 489 50 kA 250 V DC UL 489

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Similar products from: Schneider Electric Industrial Automation Components

Manufacturer warranty

BJA360506 Schneider Electric

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare BJA360506 with other Industrial Automation Components products

Device Short Name

Line Rated Current

Control Type

Trip Unit Technology

Electrical Durability

Depth

Number Of Poles

[Ui] Rated Insulation Vol...

Connection Pitch

[Ue] Rated Operational Vo...

Selected product

BJA360506
Backordered
BJA360506
Schneider Electric

Schneider Electric - BJA360506

Device Short NameBJ 050

Line Rated Current50 A

Control TypeToggle

Trip Unit TechnologyThermal-magnetic

Electrical Durability10000 cycles IEC 947-1 Annex...

Depth3.50 in (89 mm)

Number Of Poles3P

[Ui] Rated Insulation Voltage800 V IEC 60947-2

Connection Pitch1.06 in (27 mm)

[Ue] Rated Operational Voltage690 V AC 50/60 Hz UL 489

BDF36015
4 in stock
BDF36015
Schneider Electric

Square D by Schneider Electric BDF36015 is a Moulded Case Circuit Breaker (MCCB) within the PowerPac...

Device Short NameBD 015

Line Rated Current15 A

Control TypeToggle

Trip Unit Technology-

Electrical Durability-

Depth-

Number Of Poles3P

[Ui] Rated Insulation Voltage-

Connection Pitch-

[Ue] Rated Operational Voltage525 V AC 50/60 Hz UL 489

BDL36020
16 in stock
BDL36020
Schneider Electric

Square D by Schneider Electric BDL36020 is a Moulded Case Circuit Breaker (MCCB) within the PowerPac...

Device Short NameBD 020

Line Rated Current20 A

Control TypeToggle

Trip Unit Technology-

Electrical Durability-

Depth-

Number Of Poles3P

[Ui] Rated Insulation Voltage-

Connection Pitch-

[Ue] Rated Operational Voltage525 V AC 50/60 Hz UL 489

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

Recently viewed products

Relevant products

BJA36040 on Powermatic Associates

BJA36040

Verified stock: 0

Square D by Schneider Electric BJA36040 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJA sub-range, featuring a PowerPact B-Frame 100 TMD 3P 40A 600Y/347Vac 25kA I-line design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection for ABC phases with a degree of protection rated at IP40. The rated current is 40A, with a rated voltage (AC) of 600Vac 600Y/347Vac. This MCCB is designed for mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism for robust attachment. It features 3 poles (3P), with dimensions of 137 mm in height, 89 mm in depth, and 81 mm in width. The utilisation category is A. Protection settings include over-current fixed at 40A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. Protection functions cover thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 40 AT. Electrical durability with load is rated at 10,000 operations at 440Vac; In. The frame current rating is 100 AF, operating mode is toggle (manual), and the short circuit breaking rating varies with voltage, including 100kA at 240Vac, 65kA at 480Vac and 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

BJA36025 on Powermatic Associates

BJA36025

Verified stock: 0

Square D by Schneider Electric BJA36025 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJA sub-range, featuring a PowerPact B-Frame 100 TMD 3P 25A design for 600Y/347Vac with a 25kA I-line ABC 80% rated. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection for ABC phases. The degree of protection is IP40, with a rated current of 25A and a rated voltage (AC) of 600Vac 600Y/347Vac. This MCCB offers mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism. It has 3 poles (3P), with dimensions of 137 mm in height, 89 mm in depth, and 81 mm in width. The utilisation category is A. Protection settings include over-current fixed at 25A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. It features thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 25 AT. Electrical durability with load is 10,000 operations at 440Vac; In. The frame current rating is 100 AF, with a toggle (manual) operating mode. The short circuit breaking rating includes 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all according to UL489. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

BJA36100 on Powermatic Associates

BJA36100

Verified stock: 0

Square D by Schneider Electric BJA36100 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJA range, featuring a PowerPact B-Frame 100 TMD 3P 100A 600Y/347Vac 25kA I-line design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection for ABC phases with a degree of protection rated at IP40. The rated current is 100A, with a rated voltage (AC) of 600Vac 600Y/347Vac. This MCCB is designed for mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism for robust attachment. It features 3 poles (3P), has a net height of 137 mm, a net depth of 89 mm, and a net width of 81 mm. The utilisation category is A. Protection settings include over-current fixed at 100A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. Protection functions cover thermal protection (overload) and magnetic protection (short-circuit), with a trip current rating of 100 AT. Electrical durability with load is rated for 10,000 operations at 440Vac; In. The frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating includes 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, and 25kA at 600Y/347Vac under UL489 standards, with a 50kA rating at 250Vdc. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

FAQ

Out if stock but available for backorder.

Schneider Electric - BJA360506

Similar products from: Industrial Automation Components

What can I help you find today?

Recommended parts