Product description
Schneider Electric LTMR08MBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management including control modes such as local via terminal block, local via HMI terminal, and remote via network. It supports various operating modes including overload, independent, reverser, 2-step, 2-speed, and custom mode. The device offers fault management features like manual, automatic, and remote reset, alongside protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, fault history, and diagnostics for internal watchdog fault, controller internal temperature, temperature sensor connection, current connection, voltage connection, motor control commands, control configuration checksum, and loss of communication. It records motor statistics like the number of motor control commands, operating time, number of starts per hour, last start I max, duration of last start, and thermal overload statistics including time to trip and time to restart. System operating statistics such as run, on, start, alarm, and fault are also tracked. The LTMR08MBD features a 3-pole connection with 3 measurement current transformers (control circuit) using screw-clamp terminals and communicates via the Modbus protocol. It offers protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variation, earth fault, and frequent starting. The device is rated for currents from 0.4 to 8 A (maximum with CT) 800 A, with protection settings adjustable for various parameters. It operates on a supply voltage of 24 V DC and a rated voltage (AC) phase-to-phase of 690 V at 50-60Hz, with a minimum current of 0.4 A and a maximum of 8 A. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise.
Product Details
- Supply Voltage Limits 20.4…26.24 V DC
- Overvoltage Category III
- Net Weight 1.17 lb(US) (0.53 kg)
- Measurement Current 0.4…8 A
- Product Or Component Type Motor controller
- Communication Port Protocol Modbus
- Maximum Output Switching Frequency 2 Hz
- Width 3.58 in (91 mm)
- Product Name TeSys T
- Input Current 7 mA
- Web Services Web server
- Tightening Torque Control circuit 4.43…5.31 lbf.in (0.5…0.6 N.m) flat 0.12 in (3 mm)
- Device Short Name LTMR
- Logic Input Number 6
- Pollution Degree 3
- Compatibility Code LTMR
- [Us] Rated Supply Voltage 24 V DC
- Short-Circuit Withstand 100 kA EN/IEC 60947-4-1
- Current State 0 Guaranteed Logic input < 5 V <= 15 mA 5 ms
- Height 2.40 in (61 mm)
- Current Consumption 56...127 mA
- Range TeSys
- Device Application Equipment monitoring and control
- Current State 1 Guaranteed Logic input < 15 V 2...15 mA 15 ms
- Depth 4.82 in (122.5 mm)
- Maximum Operating Rate 1800 cyc/h
- Connection Pitch 0.20 in (5.08 mm)
- Associated Fuse Rating 4 A gG output 0.5 A gG control circuit
- Contacts Type And Composition 1 NO + 1 NC fault signal 3 NO
- Bus Type Modbus 2-wire RS 485 1...247 1.2...19.2 kbit/s, RJ45 2 shielded twisted pairs Modbus 2-wire RS 485 1...247 1.2...19.2 kbit/s, terminal block 2 shielded twisted pairs
- Load Current 5 A 250 V AC logic output 5 A 30 V DC logic output
- Permissible Power 480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
- [Uimp] Rated Impulse Withstand Voltage 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV communication circuit EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1
- Connections - Terminals Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.00…0.00 in² (0.25…2
- [Ui] Rated Insulation Voltage 690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508
- Electromagnetic Compatibility Electrostatic discharge, 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2) Radiated RF fields, 3 10 V/m)EN/IEC 61000-4-3) Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4) Fast transients immunity test, level 4 4 kV)EN/IEC 61000-4-4)
- Metering Type
Average current Iavg Earth-fault current Phase current I1, I2, I3 RMS Imbalance current Temperature- Network And Machine Diagnosis Type
Running hours counter/operating time Trip history information Phase fault and earth fault trip counters Fault recording Waiting time after overload tripping Remaining operating time before overload tripping Trip context infor- Measurement Accuracy
5...15 % earth fault current internal measurement 1 % voltage 100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 Temperature 1 % current 5 % active and reactive- Protection Type
Phase unbalance Locked rotor Power factor variation Load fluctuation Overload Overload (long time) Phase failure Thermal protection Thermal overload protection Earth-leakage protection Reverse polarity pro - Metering Type
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LTMR08MBD on Powermatic Associates is $1,002.38. Order now.
LTMR08MBD Related Documents
Similar products from: Schneider Electric Industrial Automation Components
Manufacturer warranty
LTMR08MBD Schneider Electric
$1,002.38
Your price can be lower.
Log in or Create account to check your discount
Select Qty:
$1,002.38
$1,002.38 each
Average response time: 11 minutes
Worldwide Shipping and Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare LTMR08MBD with other Industrial Automation Components products
Supply Voltage Limits
Overvoltage Category
Net Weight
Measurement Current
Product Or Component Type
Communication Port Protoc...
Maximum Output Switching ...
Width
Product Name
Input Current
Selected product

LTMR08MBD
Schneider Electric
Schneider Electric LTMR08MBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive mo...
Supply Voltage Limits20.4…26.24 V DC
Overvoltage CategoryIII
Net Weight1.17 lb(US) (0.53 kg)
Measurement Current0.4…8 A
Product Or Component TypeMotor controller
Communication Port ProtocolModbus
Maximum Output Switching Frequency2 Hz
Width3.58 in (91 mm)
Product NameTeSys T
Input Current7 mA
About the manufacturer
Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...
Recently viewed products
Relevant products
FAQ
What is the price of LTMR08MBD?
Purchase the LTMR08MBD from Powermatic Associates at the price of $1,002.38. Order today.
Out if stock but available for backorder.
Schneider Electric LTMR08MBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management including control modes such as local via terminal block, local via HMI terminal, and remote via network. It supports various operating modes including overload, independent, reverser, 2-step, 2-speed, and custom mode. The device offers fault management features like manual, automatic, and remote reset, alongside protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, fault history, and diagnostics for internal watchdog fault, controller internal temperature, temperature sensor connection, current connection, voltage connection, motor control commands, control configuration checksum, and loss of communication. It records motor statistics like the number of motor control commands, operating time, number of starts per hour, last start I max, duration of last start, and thermal overload statistics including time to trip and time to restart. System operating statistics such as run, on, start, alarm, and fault are also tracked. The LTMR08MBD features a 3-pole connection with 3 measurement current transformers (control circuit) using screw-clamp terminals and communicates via the Modbus protocol. It offers protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variation, earth fault, and frequent starting. The device is rated for currents from 0.4 to 8 A (maximum with CT) 800 A, with protection settings adjustable for various parameters. It operates on a supply voltage of 24 V DC and a rated voltage (AC) phase-to-phase of 690 V at 50-60Hz, with a minimum current of 0.4 A and a maximum of 8 A. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise.
Similar products from: Industrial Automation Components
What can I help you find today?