LTMR08MBD Schneider Electric Industrial Automation Components


Part#:LTMR08MBD
Manufacturer:Schneider Electric
Category:Industrial Automation Components
Product Lifecycle:Active
Product description
Schneider Electric LTMR08MBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management including control modes such as local via terminal block, local via HMI terminal, and remote via network. It supports various operating modes including overload, independent, reverser, 2-step, 2-speed, and custom mode. The device offers fault management features like manual, automatic, and remote reset, alongside protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, fault history, and diagnostics for internal watchdog fault, controller internal temperature, temperature sensor connection, current connection, voltage connection, motor control commands, control configuration checksum, and loss of communication. It records motor statistics like the number of motor control commands, operating time, number of starts per hour, last start I max, duration of last start, and thermal overload statistics including time to trip and time to restart. System operating statistics such as run, on, start, alarm, and fault are also tracked. The LTMR08MBD features a 3-pole connection with 3 measurement current transformers (control circuit) using screw-clamp terminals and communicates via the Modbus protocol. It offers protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variation, earth fault, and frequent starting. The device is rated for currents from 0.4 to 8 A (maximum with CT) 800 A, with protection settings adjustable for various parameters. It operates on a supply voltage of 24 V DC and a rated voltage (AC) phase-to-phase of 690 V at 50-60Hz, with a minimum current of 0.4 A and a maximum of 8 A. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise.
Product Details
- Protection Type Phase unbalance Locked rotor Power factor variation Load fluctuation Overload Overload (long time) Phase failure Thermal protection Thermal overload protection Earth-leakage protection Reverse polarity pro
- Measurement Accuracy 5...15 % earth fault current internal measurement 1 % voltage 100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 Temperature 1 % current 5 % active and reactive
- Network And Machine Diagnosis Type Running hours counter/operating time Trip history information Phase fault and earth fault trip counters Fault recording Waiting time after overload tripping Remaining operating time before overload tripping Trip context infor
- Metering Type Average current Iavg Earth-fault current Phase current I1, I2, I3 RMS Imbalance current Temperature
- Electromagnetic Compatibility Electrostatic discharge, 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2) Radiated RF fields, 3 10 V/m)EN/IEC 61000-4-3) Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4) Fast transients immunity test, level 4 4 kV)EN/IEC 61000-4-4)
- [Ui] Rated Insulation Voltage
690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508- [Uimp] Rated Impulse Withstand Voltage
6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV communication circuit EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1- Connections - Terminals
Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.00…0.00 in² (0.25…2- Load Current
5 A 250 V AC logic output 5 A 30 V DC logic output- Permissible Power
480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output)- Bus Type
Modbus 2-wire RS 485 1...247 1.2...19.2 kbit/s, RJ45 2 shielded twisted pairs Modbus 2-wire RS 485 1...247 1.2...19.2 kbit/s, terminal block 2 shielded twisted pairs- Associated Fuse Rating
4 A gG output 0.5 A gG control circuit- Contacts Type And Composition
1 NO + 1 NC fault signal 3 NO- Maximum Operating Rate
1800 cyc/h- Connection Pitch
0.20 in (5.08 mm)- Web Services
Web server- Compatibility Code
LTMR- Tightening Torque
Control circuit 4.43…5.31 lbf.in (0.5…0.6 N.m) flat 0.12 in (3 mm)- Net Weight
1.17 lb(US) (0.53 kg)- Depth
4.82 in (122.5 mm)- Width
3.58 in (91 mm)- Height
2.40 in (61 mm)- Overvoltage Category
III- Pollution Degree
3- Current State 0 Guaranteed
Logic input < 5 V <= 15 mA 5 ms- Maximum Output Switching Frequency
2 Hz- Input Current
7 mA- Logic Input Number
6- Current State 1 Guaranteed
Logic input < 15 V 2...15 mA 15 ms- Short-Circuit Withstand
100 kA EN/IEC 60947-4-1- Communication Port Protocol
Modbus- Measurement Current
0.4…8 A- Supply Voltage Limits
20.4…26.24 V DC- Current Consumption
56...127 mA- [Us] Rated Supply Voltage
24 V DC- Product Or Component Type
Motor controller- Device Application
Equipment monitoring and control- Range
TeSys- Device Short Name
LTMR- Product Name
TeSys TProduct condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LTMR08MBD on Powermatic Associates is $1,002.38. Order now.LTMR08MBD Related Documents
Similar products from: Schneider Electric Industrial Automation Components
Manufacturer warranty
LTMR08MBD Schneider Electric
$1,002.38
Your price can be lower.
Log in or Create account to check your discountSelect Qty:
$1,002.38
$1,002.38 each
Average response time: 11 minutes
Worldwide Shipping and Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
- [Ui] Rated Insulation Voltage
Compare LTMR08MBD with other Industrial Automation Components products
Protection Type
Measurement Accuracy
Network And Machine Diagn...
Metering Type
Electromagnetic Compatibi...
[Ui] Rated Insulation Vol...
[Uimp] Rated Impulse With...
Connections - Terminals
Load Current
Permissible Power
Selected product

LTMR08MBD
Schneider Electric
Schneider Electric LTMR08MBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive mo...
Protection TypePhase unbalance Locked rotor...
Measurement Accuracy5...15 % earth fault current...
Network And Machine Diagnosis TypeRunning hours counter/operat...
Metering TypeAverage current Iavg Earth-f...
Electromagnetic CompatibilityElectrostatic discharge, 3 8...
[Ui] Rated Insulation Voltage690 V EN/IEC 60947-1 690 V C...
[Uimp] Rated Impulse Withstand Voltage6 kV current or voltage meas...
Connections - TerminalsControl circuit connector 1 ...
Load Current5 A 250 V AC logic output 5 ...
Permissible Power480 VA AC-15), Ie = 2 A, 500...
About the manufacturer
Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...
Recently viewed products
Relevant products
FAQ
What is the price of LTMR08MBD?
Purchase the LTMR08MBD from Powermatic Associates at the price of $1,002.38. Order today.
Out if stock but available for backorder.
Schneider Electric LTMR08MBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management including control modes such as local via terminal block, local via HMI terminal, and remote via network. It supports various operating modes including overload, independent, reverser, 2-step, 2-speed, and custom mode. The device offers fault management features like manual, automatic, and remote reset, alongside protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, fault history, and diagnostics for internal watchdog fault, controller internal temperature, temperature sensor connection, current connection, voltage connection, motor control commands, control configuration checksum, and loss of communication. It records motor statistics like the number of motor control commands, operating time, number of starts per hour, last start I max, duration of last start, and thermal overload statistics including time to trip and time to restart. System operating statistics such as run, on, start, alarm, and fault are also tracked. The LTMR08MBD features a 3-pole connection with 3 measurement current transformers (control circuit) using screw-clamp terminals and communicates via the Modbus protocol. It offers protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variation, earth fault, and frequent starting. The device is rated for currents from 0.4 to 8 A (maximum with CT) 800 A, with protection settings adjustable for various parameters. It operates on a supply voltage of 24 V DC and a rated voltage (AC) phase-to-phase of 690 V at 50-60Hz, with a minimum current of 0.4 A and a maximum of 8 A. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise.
Similar products from: Industrial Automation Components
What can I help you find today?