LTMR100MBD Schneider Electric Industrial Automation Components

LTMR100MBD on Powermatic Associates
Schneider Electric

Part#:LTMR100MBD

Manufacturer:Schneider Electric

Category:Industrial Automation Components

Product Lifecycle:Active

Product description

Schneider Electric LTMR100MBD, part of the LTMR (TeSys T) sub-range, is designed for motor management with a variety of control modes including local via terminal block, local via HMI terminal, and remote via network. It supports operating modes such as overload, independent, reverser, 2-step, 2-speed, and custom mode. The part offers comprehensive fault management capabilities with manual, automatic, and remote reset options, alongside protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and fault history. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor connection, current connection, voltage connection, motor control commands, control configuration checksum, and loss of communication. Motor statistics provided include the number of motor control commands, operating time, number of starts per hour, last start I max, and duration of last start. Thermal overload statistics cover time to trip and time to restart, while system operating statistics include run, on, start, alarm, and fault indicators. The connection type is 3 measurement current transformers with screw-clamp terminals, and it uses the Modbus communication protocol. It is a 3 Pole device with protection functions for thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variation, earth fault, and frequent starting. Rated current ranges from 5-100 A with protection settings adjustable for various conditions. The supply voltage is 24 V DC, and the rated voltage for AC phase-to-phase is up to 690 V at 50-60Hz. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise, accommodating a wide range of monitoring and protection needs for motor management.

Product Details

  • Measurement Current
    5…100 A
  • Logic Input Number
    6
  • Depth
    4.82 in (122.5 mm)
  • Current Consumption
    56...127 mA
  • Input Current
    7 mA
  • Height
    2.40 in (61 mm)
  • Connection Pitch
    0.20 in (5.08 mm)
  • Device Short Name
    LTMR
  • Maximum Output Switching Frequency
    2 Hz
  • Supply Voltage Limits
    20.4…26.24 V DC
  • Product Name
    TeSys T
  • Current State 1 Guaranteed
    Logic input < 15 V 2...15 mA 15 ms
  • Tightening Torque
    Control circuit 4.43…5.31 lbf.in (0.5…0.6 N.m) flat 0.12 in (3 mm)
  • Product Or Component Type
    Motor controller
  • Net Weight
    1.17 lb(US) (0.53 kg)
  • Width
    3.58 in (91 mm)
  • Range
    TeSys
  • Current State 0 Guaranteed
    Logic input < 5 V <= 15 mA 5 ms
  • [Us] Rated Supply Voltage
    24 V DC
  • Short-Circuit Withstand
    100 kA EN/IEC 60947-4-1
  • Maximum Operating Rate
    1800 cyc/h
  • Pollution Degree
    3
  • Device Application
    Equipment monitoring and control
  • Communication Port Protocol
    Modbus
  • Overvoltage Category
    III
  • Compatibility Code
    LTMR
  • Web Services
    Web server
  • Contacts Type And Composition
    1 NO + 1 NC fault signal 3 NO
  • Metering Type
    Phase current I1, I2, I3 RMS Temperature Average current Iavg Earth-fault current Imbalance current
  • Associated Fuse Rating
    4 A gG output 0.5 A gG control circuit
  • Load Current
    5 A 250 V AC logic output 5 A 30 V DC logic output
  • Permissible Power
    480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
  • Bus Type
    Modbus 2-wire RS 485 1...247 1.2...19.2 kbit/s, RJ45 2 shielded twisted pairs Modbus 2-wire RS 485 1...247 1.2...19.2 kbit/s, terminal block 2 shielded twisted pairs
  • [Ui] Rated Insulation Voltage
    690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508
  • [Uimp] Rated Impulse Withstand Voltage
    6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV communication circuit EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1
  • Connections - Terminals
    Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.00…0.00 in² (0.25…2
  • Electromagnetic Compatibility
    Electrostatic discharge, 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2) Radiated RF fields, 3 10 V/m)EN/IEC 61000-4-3) Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4) Fast transients immunity test, level 4 4 kV)EN/IEC 61000-4-4)
  • Protection Type
    Thermal overload protection Phase unbalance Overload (long time) Phase failure Thermal protection Power factor variation Reverse polarity protection Overload Locked rotor Load fluctuation Earth-leakage pro
  • Network And Machine Diagnosis Type
    Remaining operating time before overload tripping Phase fault and earth fault trip counters Fault recording Waiting time after overload tripping Motor control command recording Event recording Starting current and time T
  • Measurement Accuracy
    5...15 % earth fault current internal measurement 1 % voltage 100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 Temperature 5 % active and reactive power 0,02

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Similar products from: Schneider Electric Industrial Automation Components

Manufacturer warranty

LTMR100MBD Schneider Electric

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare LTMR100MBD with other Industrial Automation Components products

Measurement Current

Logic Input Number

Depth

Current Consumption

Input Current

Height

Connection Pitch

Device Short Name

Maximum Output Switching ...

Supply Voltage Limits

Selected product

LTMR100MBD
Backordered
LTMR100MBD
Schneider Electric

Schneider Electric LTMR100MBD, part of the LTMR (TeSys T) sub-range, is designed for motor managemen...

Measurement Current5…100 A

Logic Input Number6

Depth4.82 in (122.5 mm)

Current Consumption56...127 mA

Input Current7 mA

Height2.40 in (61 mm)

Connection Pitch0.20 in (5.08 mm)

Device Short NameLTMR

Maximum Output Switching Frequency2 Hz

Supply Voltage Limits20.4…26.24 V DC

LC1D40ABD
2 in stock
LC1D40ABD
Schneider Electric

Schneider Electric LC1D40ABD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM)...

Measurement Current-

Logic Input Number-

Depth-

Current Consumption-

Input Current-

Height-

Connection Pitch-

Device Short NameLC1D

Maximum Output Switching Frequency-

Supply Voltage Limits-

M9F53220
1 in stock
M9F53220
Schneider Electric

Schneider Electric M9F53220 is a Miniature Circuit Breaker (MCB) within the C60BPR sub-range, design...

Measurement Current-

Logic Input Number-

Depth-

Current Consumption-

Input Current-

Height-

Connection Pitch-

Device Short NameC60BPR

Maximum Output Switching Frequency-

Supply Voltage Limits-

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

Recently viewed products

Relevant products

LTMR27DBD on Powermatic Associates

LTMR27DBD

Verified stock: 0

Schneider Electric LTMR27DBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation via network. The device offers multiple operating modes such as Overload, Independent, Reverser, 2-step, 2-speed, and Custom mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics like protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, fault history, and more. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor, current, and voltage connections, motor control commands, control configuration checksum, and loss of communication. Motor and thermal overload statistics provide insights into motor control commands, operating time, starts per hour, last start I max, duration of last start, time to trip, and time to restart. System operating statistics cover run, on, start, alarm, and fault statuses. Connection is facilitated through 3 measurement current transformers with a screw-clamp type, utilizing the DeviceNet communication protocol. It is a 3 Pole device with protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variations, and earth fault. The rated current ranges from 1.35-27 A with protection settings adjustable for various conditions. Supply voltage is DC 24 V, with a rated voltage for AC phase-to-phase at 50-60Hz 690 V. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise, catering to a broad spectrum of monitoring and protection needs.

Schneider Electric

LTMR27PFM on Powermatic Associates

LTMR27PFM

Verified stock: 0

Schneider Electric LTMR27PFM, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation through a network. The operating modes it accommodates are Overload, Independent, Reverser, 2-step, 2-speed, and a customizable "Custom" mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics such as protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and a detailed fault history. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor, current, and voltage connections, motor control commands, control configuration checksum, and loss of communication. Motor and thermal overload statistics provide insights into motor control commands, operating time, starts per hour, last start current max, duration of last start, time to trip, and time to restart. System operating statistics cover run, on, start, alarm, and fault statuses. The connection type is a 3 measurement current transformer control circuit with screw-clamp terminals, utilizing the Profibus communication protocol. It is a 3 Pole device with protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variations, earth fault, and frequent starting. The rated current ranges from 1.35-27 A with protection settings adjustable for various conditions. Supply voltage is AC 100-240 V, with a rated voltage for phase-to-phase at 50-60Hz being 690 V. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise, ensuring comprehensive monitoring and protection for motor applications.

Schneider Electric

LTMR100CBD on Powermatic Associates

LTMR100CBD

Verified stock: 0

Schneider Electric LTMR100CBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation through a network. The operating modes it accommodates are Overload, Independent, Reverser, 2-step, 2-speed, and a customizable "Custom" mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics such as protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and a detailed fault history. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor, current, and voltage connections, as well as motor control commands and loss of communication. Motor statistics provided include the number of motor control commands, operating time, number of starts per hour, last start I max, and duration of last start. Thermal overload statistics offer insights into time to trip and time to restart, while system operating statistics cover run, on, start, alarm, and fault statuses. The LTMR100CBD uses 3 measurement current transformers with a screw-clamp connection type and operates on the CANopen communication protocol. It is a 3 Pole device with protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variations, and earth fault. It also includes a feature to inhibit start in case of frequent starting, protecting the motor from overheating. The rated current range is 5-100 A, with protection settings adjustable for various parameters including thermal overload, motor temperature, phase imbalance, phase failure, and more. The supply voltage is 24 V DC, with a rated voltage for AC phase-to-phase operation at 690 V (50-60Hz). Measurement functions cover a wide range of current and temperature parameters, ensuring comprehensive monitoring and protection for connected motors.

Schneider Electric

LTMR100EFM on Powermatic Associates

LTMR100EFM

Verified stock: 0

Schneider Electric LTMR100EFM, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation through a network. The operating modes it accommodates are Overload, Independent, Reverser, 2-step, 2-speed, and a customizable "Custom" mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics like protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, fault history, and more. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor connection, current and voltage connection, motor control commands, control configuration checksum, and loss of communication. Motor statistics provided include the number of motor control commands, operating time, number of starts per hour, last start I max, and duration of last start. Thermal overload statistics and system operating statistics offer insights into the time to trip, time to restart, and run/on/start/alarm/fault statuses. The connection type is through 3 measurement current transformers with a screw-clamp control circuit, and it uses an Ethernet TCP/IP Modbus TCP communication protocol. This 3 Pole device offers protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variations, earth fault, and frequent starting. Rated current ranges from 5-100 A with protection settings adjustable for various conditions. Supply voltage is AC 100-240 V, with a rated voltage (AC) phase-to-phase of 690 V at 50-60Hz. Measurement functions cover a wide range of parameters including current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise.

Schneider Electric

LTMR27EFM on Powermatic Associates

LTMR27EFM

Verified stock: 0

Schneider Electric LTMR27EFM, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation via network. The operating modes it accommodates are Overload, Independent, Reverser, 2-step, 2-speed, and a customizable "Custom" mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics such as protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and a detailed fault history. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor, current, and voltage connections, motor control commands, control configuration checksum, and loss of communication. Motor and thermal overload statistics provide insights into the number of motor control commands, operating time, starts per hour, last start's maximum current, duration of last start, time to trip, and time to restart. System operating statistics cover run, on, start, alarm, and fault statuses. The connection type is through 3 measurement current transformers with a screw-clamp control circuit, and it uses an Ethernet TCP/IP Modbus TCP communication protocol. This 3 Pole device offers protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variations, earth fault, and frequent starting. Rated current ranges from 1.35-27 A with protection settings adjustable for various conditions. Supply voltage is AC 100-240 V, with a rated voltage for phase-to-phase at 50-60Hz being 690 V. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise, ensuring comprehensive monitoring and protection for motor applications.

Schneider Electric

FAQ

Out if stock but available for backorder.

Schneider Electric LTMR100MBD, part of the LTMR (TeSys T) sub-range, is designed for motor management with a variety of control modes including local via terminal block, local via HMI terminal, and remote via network. It supports operating modes such as overload, independent, reverser, 2-step, 2-speed, and custom mode. The part offers comprehensive fault management capabilities with manual, automatic, and remote reset options, alongside protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and fault history. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor connection, current connection, voltage connection, motor control commands, control configuration checksum, and loss of communication. Motor statistics provided include the number of motor control commands, operating time, number of starts per hour, last start I max, and duration of last start. Thermal overload statistics cover time to trip and time to restart, while system operating statistics include run, on, start, alarm, and fault indicators. The connection type is 3 measurement current transformers with screw-clamp terminals, and it uses the Modbus communication protocol. It is a 3 Pole device with protection functions for thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variation, earth fault, and frequent starting. Rated current ranges from 5-100 A with protection settings adjustable for various conditions. The supply voltage is 24 V DC, and the rated voltage for AC phase-to-phase is up to 690 V at 50-60Hz. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise, accommodating a wide range of monitoring and protection needs for motor management.

Similar products from: Industrial Automation Components

What can I help you find today?

Recommended parts