LTMR100EBD Schneider Electric Industrial Automation Components


Part#:LTMR100EBD
Manufacturer:Schneider Electric
Category:Industrial Automation Components
Product Lifecycle:Active
Product description
Schneider Electric LTMR100EBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation through a network. The operating modes it accommodates are Overload, Independent, Reverser, 2-step, 2-speed, and a customizable "Custom" mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics such as protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and a fault history log. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor, current, and voltage connections, as well as motor control commands and a control configuration checksum. The LTMR100EBD also monitors loss of communication and provides detailed motor and thermal overload statistics, including the number of motor control commands, operating time, number of starts per hour, and the duration and intensity of the last start. System operating statistics cover run, on, start, alarm, and fault statuses. Connection is facilitated through 3 measurement current transformers with a screw-clamp control circuit. It uses an Ethernet TCP/IP Modbus TCP communication protocol and is designed for 3 Pole(s) configurations. Protection functions include thermal overload, motor temperature monitoring with up to 3 sensors, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variations, and earth fault detection. It supports frequent starting protection to prevent motor overheating. Rated for a current range of 5-100 A, it offers adjustable protection settings for thermal overload, motor temperature, phase imbalance and failure, phase reversal, long starting time, locked rotor, current load limit variations, and earth faults. The supply voltage is DC 24 V, with a phase-to-phase rated voltage for AC at 50-60Hz up to 690 V. The minimum current capability is 5 A, and the maximum is 100 A. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise, covering a broad range of monitoring needs.
Product Details
- Protection Type Locked rotor Overload Thermal overload protection Earth-leakage protection Reverse polarity protection Overload (long time) Power factor variation Phase unbalance Load fluctuation Phase failure Thermal pro
- Network And Machine Diagnosis Type Fault recording Trip context information Waiting time after overload tripping Trip history information Running hours counter/operating time Motor control command recording Starting current and time Phase fault and earth
- Measurement Accuracy 5...15 % earth fault current internal measurement 1 % voltage 100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 Temperature 5 % active and reactive power 0,02
- Metering Type Average current Iavg Earth-fault current Temperature Phase current I1, I2, I3 RMS Imbalance current
- Electromagnetic Compatibility Electrostatic discharge, 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2) Radiated RF fields, 3 10 V/m)EN/IEC 61000-4-3) Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4) Fast transients immunity test, level 4 4 kV)EN/IEC 61000-4-4)
- [Uimp] Rated Impulse Withstand Voltage
6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV communication circuit EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1- Connections - Terminals
Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.00…0.00 in² (0.25…2- [Ui] Rated Insulation Voltage
690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508- Permissible Power
480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output)- Associated Fuse Rating
4 A gG output 0.5 A gG control circuit- Contacts Type And Composition
1 NO + 1 NC fault signal 3 NO- Load Current
5 A 250 V AC logic output 5 A 30 V DC logic output- Web Services
Web server- Compatibility Code
LTMR- Net Weight
1.17 lb(US) (0.53 kg)- Height
2.40 in (61 mm)- Width
3.58 in (91 mm)- Tightening Torque
Control circuit 4.43…5.31 lbf.in (0.5…0.6 N.m) flat 0.12 in (3 mm)- Pollution Degree
3- Connection Pitch
0.20 in (5.08 mm)- Depth
4.82 in (122.5 mm)- Overvoltage Category
III- Maximum Operating Rate
1800 cyc/h- Maximum Output Switching Frequency
2 Hz- Current State 1 Guaranteed
Logic input < 15 V 2...15 mA 15 ms- Current State 0 Guaranteed
Logic input < 5 V <= 15 mA 5 ms- Logic Input Number
6- Input Current
7 mA- Short-Circuit Withstand
100 kA EN/IEC 60947-4-1- Communication Port Protocol
Modbus TCP/EtherNet/IP- Bus Type
Ethernet IEEE 802.3 0...159 10...100 Mbit/s, RJ45 2 shielded twisted pairs- Supply Voltage Limits
20.4…26.24 V DC- Current Consumption
56...127 mA- [Us] Rated Supply Voltage
24 V DC- Measurement Current
5…100 A- Device Application
Equipment monitoring and control- Product Or Component Type
Motor controller- Device Short Name
LTMR- Product Name
TeSys T- Range
TeSysProduct condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LTMR100EBD on Powermatic Associates is $1,014.76. Order now.LTMR100EBD Related Documents
Similar products from: Schneider Electric Industrial Automation Components
Manufacturer warranty
LTMR100EBD Schneider Electric
$1,014.76
Your price can be lower.
Log in or Create account to check your discountSelect Qty:
$1,014.76
$1,014.76 each
Average response time: 11 minutes
Worldwide Shipping and Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
- [Uimp] Rated Impulse Withstand Voltage
Compare LTMR100EBD with other Industrial Automation Components products
Protection Type
Network And Machine Diagn...
Measurement Accuracy
Metering Type
Electromagnetic Compatibi...
[Uimp] Rated Impulse With...
Connections - Terminals
[Ui] Rated Insulation Vol...
Permissible Power
Associated Fuse Rating
Selected product

LTMR100EBD
Schneider Electric
Schneider Electric LTMR100EBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive m...
Protection TypeLocked rotor Overload Therma...
Network And Machine Diagnosis TypeFault recording Trip context...
Measurement Accuracy5...15 % earth fault current...
Metering TypeAverage current Iavg Earth-f...
Electromagnetic CompatibilityElectrostatic discharge, 3 8...
[Uimp] Rated Impulse Withstand Voltage6 kV current or voltage meas...
Connections - TerminalsControl circuit connector 1 ...
[Ui] Rated Insulation Voltage690 V EN/IEC 60947-1 690 V C...
Permissible Power480 VA AC-15), Ie = 2 A, 500...
Associated Fuse Rating4 A gG output 0.5 A gG contr...
About the manufacturer
Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...
Recently viewed products
Relevant products
FAQ
What is the price of LTMR100EBD?
Purchase the LTMR100EBD from Powermatic Associates at the price of $1,014.76. Order today.
Out if stock but available for backorder.
Schneider Electric LTMR100EBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation through a network. The operating modes it accommodates are Overload, Independent, Reverser, 2-step, 2-speed, and a customizable "Custom" mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics such as protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and a fault history log. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor, current, and voltage connections, as well as motor control commands and a control configuration checksum. The LTMR100EBD also monitors loss of communication and provides detailed motor and thermal overload statistics, including the number of motor control commands, operating time, number of starts per hour, and the duration and intensity of the last start. System operating statistics cover run, on, start, alarm, and fault statuses. Connection is facilitated through 3 measurement current transformers with a screw-clamp control circuit. It uses an Ethernet TCP/IP Modbus TCP communication protocol and is designed for 3 Pole(s) configurations. Protection functions include thermal overload, motor temperature monitoring with up to 3 sensors, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variations, and earth fault detection. It supports frequent starting protection to prevent motor overheating. Rated for a current range of 5-100 A, it offers adjustable protection settings for thermal overload, motor temperature, phase imbalance and failure, phase reversal, long starting time, locked rotor, current load limit variations, and earth faults. The supply voltage is DC 24 V, with a phase-to-phase rated voltage for AC at 50-60Hz up to 690 V. The minimum current capability is 5 A, and the maximum is 100 A. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise, covering a broad range of monitoring needs.
Similar products from: Industrial Automation Components
What can I help you find today?