Schneider Electric LTMR27DFM, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation through a network. The LTMR27DFM offers multiple operating modes such as Overload, Independent, Reverser, 2-step, 2-speed, and Custom mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics like protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and fault history. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor connection, current connection, voltage connection, motor control commands, control configuration checksum, and loss of communication. Motor statistics provided include the number of motor control commands, operating time, number of starts per hour, last start I max, and duration of last start. Thermal overload statistics cover time to trip and time to restart, while system operating statistics monitor run, on, start, alarm, and fault statuses. The LTMR27DFM utilizes 3 measurement current transformers with a screw-clamp connection type and supports the DeviceNet communication protocol. It is a 3 Pole device with protection functions for thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variation, earth fault, and frequent starting. Rated current ranges from 1.35-27 A with protection settings adjustable for various parameters. Supply voltage is AC 100-240 V, with a rated voltage (AC) phase-to-phase of 690 V at 50-60Hz. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise.

Product Details

  • Protection Type
    Thermal overload protection Power factor variation Phase failure Overload (long time) Reverse polarity protection Earth-leakage protection Thermal protection Locked rotor Load fluctuation Overload Phase un
  • Measurement Accuracy
    5...15 % earth fault current internal measurement 1 % voltage 100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 Temperature 1 % current 5 % active and reactive
  • Network And Machine Diagnosis Type
    Trip history information Trip context information Running hours counter/operating time Remaining operating time before overload tripping Fault recording Waiting time after overload tripping Starting current and time Phas
  • Metering Type
    Imbalance current Temperature Earth-fault current Average current Iavg Phase current I1, I2, I3 RMS
  • Electromagnetic Compatibility
    Electrostatic discharge, 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2) Radiated RF fields, 3 10 V/m)EN/IEC 61000-4-3) Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4) Fast transients immunity test, level 4 4 kV)EN/IEC 61000-4-4)
  • Connections - Terminals
    Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.00…0.00 in² (0.25…2
  • [Uimp] Rated Impulse Withstand Voltage
    4 kV supply, inputs and outputs EN/IEC 60947-4-1 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV communication circuit EN/IEC 60947-4-1
  • [Ui] Rated Insulation Voltage
    690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508
  • Contacts Type And Composition
    1 NO + 1 NC fault signal 3 NO
  • Permissible Power
    480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
  • Associated Fuse Rating
    4 A gG output 0.5 A gG control circuit
  • Input Current
    3.1 mA 100 V 7.5 mA 240 V
  • Load Current
    5 A 250 V AC logic output 5 A 30 V DC logic output
  • Height
    2.40 in (61 mm)
  • Depth
    4.82 in (122.5 mm)
  • Net Weight
    1.17 lb(US) (0.53 kg)
  • Compatibility Code
    LTMR
  • Tightening Torque
    Control circuit 4.43…5.31 lbf.in (0.5…0.6 N.m) flat 0.12 in (3 mm)
  • Pollution Degree
    3
  • Web Services
    Web server
  • Width
    3.58 in (91 mm)
  • Overvoltage Category
    III
  • Connection Pitch
    0.20 in (5.08 mm)
  • Maximum Operating Rate
    1800 cyc/h
  • Maximum Output Switching Frequency
    2 Hz
  • Current State 1 Guaranteed
    Logic input 79...264 V >= 2 mA 25 ms
  • Current State 0 Guaranteed
    Logic input 0...40 V <= 15 mA 25 ms
  • Logic Input Number
    6
  • Short-Circuit Withstand
    100 kA EN/IEC 60947-4-1
  • Bus Type
    DeviceNet ISO 1198 1...64 125...500 kbit/s, terminal block 4 twisted shielded pairs cable
  • Communication Port Protocol
    DeviceNet
  • Product Name
    TeSys T
  • [Us] Rated Supply Voltage
    100...240 V AC 50/60 Hz
  • Range
    TeSys
  • Supply Voltage Limits
    93.5…264 V AC
  • Current Consumption
    8...62.8 mA
  • Measurement Current
    1.35…27 A
  • Device Short Name
    LTMR
  • Product Or Component Type
    Motor controller
  • Device Application
    Equipment monitoring and control

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LTMR27DFM on Powermatic Associates is $742.50. Order now.



Similar products from: Schneider Electric Industrial Automation Components

Manufacturer warranty

LTMR27DFM Schneider Electric

$742.50

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$742.50

$742.50 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare LTMR27DFM with other Industrial Automation Components products

Protection Type

Measurement Accuracy

Network And Machine Diagn...

Metering Type

Electromagnetic Compatibi...

Connections - Terminals

[Uimp] Rated Impulse With...

[Ui] Rated Insulation Vol...

Contacts Type And Composi...

Permissible Power

Selected product

LTMR27DFM
Backordered
LTMR27DFM
Schneider Electric

Schneider Electric LTMR27DFM, part of the LTMR (TeSys T) sub-range, is designed for comprehensive mo...

Protection TypeThermal overload protection ...

Measurement Accuracy5...15 % earth fault current...

Network And Machine Diagnosis TypeTrip history information Tri...

Metering TypeImbalance current Temperatur...

Electromagnetic CompatibilityElectrostatic discharge, 3 8...

Connections - TerminalsControl circuit connector 1 ...

[Uimp] Rated Impulse Withstand Voltage4 kV supply, inputs and outp...

[Ui] Rated Insulation Voltage690 V EN/IEC 60947-1 690 V C...

Contacts Type And Composition1 NO + 1 NC fault signal 3 N...

Permissible Power480 VA AC-15), Ie = 2 A, 500...

LC1D95M7
17 in stock
LC1D95M7
Schneider Electric

Schneider Electric LC1D95M7 is a magnetic contactor from the Deca sub-range, featuring screw connect...

Protection Type-

Measurement Accuracy-

Network And Machine Diagnosis Type-

Metering Type-

Electromagnetic Compatibility-

Connections - Terminals-

[Uimp] Rated Impulse Withstand Voltage-

[Ui] Rated Insulation VoltagePower circuit 1000 V IEC 609...

Contacts Type And Composition-

Permissible Power-

M9F43303
5 in stock
M9F43303
Schneider Electric

Schneider Electric M9F43303 is a Miniature Circuit Breaker (MCB) within the C60BP sub-range, designe...

Protection Type-

Measurement Accuracy-

Network And Machine Diagnosis Type-

Metering Type-

Electromagnetic Compatibility-

Connections - Terminals-

[Uimp] Rated Impulse Withstand Voltage-

[Ui] Rated Insulation Voltage500 V AC EN/IEC 60947-2

Contacts Type And Composition-

Permissible Power-

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

Recently viewed products

Relevant products

LTMR27DBD on Powermatic Associates

LTMR27DBD

Verified stock: 0

Schneider Electric LTMR27DBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation via network. The device offers multiple operating modes such as Overload, Independent, Reverser, 2-step, 2-speed, and Custom mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics like protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, fault history, and more. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor, current, and voltage connections, motor control commands, control configuration checksum, and loss of communication. Motor and thermal overload statistics provide insights into motor control commands, operating time, starts per hour, last start I max, duration of last start, time to trip, and time to restart. System operating statistics cover run, on, start, alarm, and fault statuses. Connection is facilitated through 3 measurement current transformers with a screw-clamp type, utilizing the DeviceNet communication protocol. It is a 3 Pole device with protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variations, and earth fault. The rated current ranges from 1.35-27 A with protection settings adjustable for various conditions. Supply voltage is DC 24 V, with a rated voltage for AC phase-to-phase at 50-60Hz 690 V. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise, catering to a broad spectrum of monitoring and protection needs.

Schneider Electric

LTMR100MBD on Powermatic Associates

LTMR100MBD

Verified stock: 0

Schneider Electric LTMR100MBD, part of the LTMR (TeSys T) sub-range, is designed for motor management with a variety of control modes including local via terminal block, local via HMI terminal, and remote via network. It supports operating modes such as overload, independent, reverser, 2-step, 2-speed, and custom mode. The part offers comprehensive fault management capabilities with manual, automatic, and remote reset options, alongside protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and fault history. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor connection, current connection, voltage connection, motor control commands, control configuration checksum, and loss of communication. Motor statistics provided include the number of motor control commands, operating time, number of starts per hour, last start I max, and duration of last start. Thermal overload statistics cover time to trip and time to restart, while system operating statistics include run, on, start, alarm, and fault indicators. The connection type is 3 measurement current transformers with screw-clamp terminals, and it uses the Modbus communication protocol. It is a 3 Pole device with protection functions for thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variation, earth fault, and frequent starting. Rated current ranges from 5-100 A with protection settings adjustable for various conditions. The supply voltage is 24 V DC, and the rated voltage for AC phase-to-phase is up to 690 V at 50-60Hz. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise, accommodating a wide range of monitoring and protection needs for motor management.

Schneider Electric

LTMR27PFM on Powermatic Associates

LTMR27PFM

Verified stock: 0

Schneider Electric LTMR27PFM, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation through a network. The operating modes it accommodates are Overload, Independent, Reverser, 2-step, 2-speed, and a customizable "Custom" mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics such as protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and a detailed fault history. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor, current, and voltage connections, motor control commands, control configuration checksum, and loss of communication. Motor and thermal overload statistics provide insights into motor control commands, operating time, starts per hour, last start current max, duration of last start, time to trip, and time to restart. System operating statistics cover run, on, start, alarm, and fault statuses. The connection type is a 3 measurement current transformer control circuit with screw-clamp terminals, utilizing the Profibus communication protocol. It is a 3 Pole device with protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variations, earth fault, and frequent starting. The rated current ranges from 1.35-27 A with protection settings adjustable for various conditions. Supply voltage is AC 100-240 V, with a rated voltage for phase-to-phase at 50-60Hz being 690 V. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise, ensuring comprehensive monitoring and protection for motor applications.

Schneider Electric

LTMR08MBD on Powermatic Associates

LTMR08MBD

Verified stock: 0

Schneider Electric LTMR08MBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management including control modes such as local via terminal block, local via HMI terminal, and remote via network. It supports various operating modes including overload, independent, reverser, 2-step, 2-speed, and custom mode. The device offers fault management features like manual, automatic, and remote reset, alongside protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, fault history, and diagnostics for internal watchdog fault, controller internal temperature, temperature sensor connection, current connection, voltage connection, motor control commands, control configuration checksum, and loss of communication. It records motor statistics like the number of motor control commands, operating time, number of starts per hour, last start I max, duration of last start, and thermal overload statistics including time to trip and time to restart. System operating statistics such as run, on, start, alarm, and fault are also tracked. The LTMR08MBD features a 3-pole connection with 3 measurement current transformers (control circuit) using screw-clamp terminals and communicates via the Modbus protocol. It offers protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variation, earth fault, and frequent starting. The device is rated for currents from 0.4 to 8 A (maximum with CT) 800 A, with protection settings adjustable for various parameters. It operates on a supply voltage of 24 V DC and a rated voltage (AC) phase-to-phase of 690 V at 50-60Hz, with a minimum current of 0.4 A and a maximum of 8 A. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise.

Schneider Electric

LTMR27MFM on Powermatic Associates

LTMR27MFM

Verified stock: 0

Schneider Electric LTMR27MFM, part of the LTMR (TeSys T) sub-range, is a motor management controller designed for comprehensive motor and system protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation via network. The operating modes it accommodates are Overload, Independent, Reverser, 2-step, 2-speed, and "Custom" mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics such as protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, fault history, and more. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor connection, current connection, voltage connection, motor control commands, control configuration checksum, and loss of communication. Motor statistics provided include the number of motor control commands, operating time, number of starts per hour, last start I max, duration of last start, and thermal overload statistics like time to trip and time to restart. System operating statistics cover run, on, start, alarm, and fault statuses. The connection type is 3 measurement current transformers with a screw-clamp terminal. It uses the Modbus communication protocol, is designed for 3 Pole(s) configurations, and offers protection functions against thermal overload, motor temperature issues, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variations, earth fault, and frequent starting. The rated current range is 1.35-27 A, with protection settings adjustable for various conditions and thresholds. The supply voltage is AC 100-240 V, with a rated voltage for phase-to-phase of 690 V at 50-60Hz. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise, supporting a broad range of monitoring and protection capabilities for industrial motor applications.

Schneider Electric

FAQ

What is the price of LTMR27DFM?
Purchase the LTMR27DFM from Powermatic Associates at the price of $742.50. Order today.

Out if stock but available for backorder.

Schneider Electric LTMR27DFM, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation through a network. The LTMR27DFM offers multiple operating modes such as Overload, Independent, Reverser, 2-step, 2-speed, and Custom mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics like protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and fault history. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor connection, current connection, voltage connection, motor control commands, control configuration checksum, and loss of communication. Motor statistics provided include the number of motor control commands, operating time, number of starts per hour, last start I max, and duration of last start. Thermal overload statistics cover time to trip and time to restart, while system operating statistics monitor run, on, start, alarm, and fault statuses. The LTMR27DFM utilizes 3 measurement current transformers with a screw-clamp connection type and supports the DeviceNet communication protocol. It is a 3 Pole device with protection functions for thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variation, earth fault, and frequent starting. Rated current ranges from 1.35-27 A with protection settings adjustable for various parameters. Supply voltage is AC 100-240 V, with a rated voltage (AC) phase-to-phase of 690 V at 50-60Hz. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise.

Similar products from: Industrial Automation Components

What can I help you find today?

Recommended parts