LTMR100CBD Schneider Electric Industrial Automation Components


Part#:LTMR100CBD
Manufacturer:Schneider Electric
Category:Industrial Automation Components
Product Lifecycle:Active
Product description
Schneider Electric LTMR100CBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation through a network. The operating modes it accommodates are Overload, Independent, Reverser, 2-step, 2-speed, and a customizable "Custom" mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics such as protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and a detailed fault history. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor, current, and voltage connections, as well as motor control commands and loss of communication. Motor statistics provided include the number of motor control commands, operating time, number of starts per hour, last start I max, and duration of last start. Thermal overload statistics offer insights into time to trip and time to restart, while system operating statistics cover run, on, start, alarm, and fault statuses. The LTMR100CBD uses 3 measurement current transformers with a screw-clamp connection type and operates on the CANopen communication protocol. It is a 3 Pole device with protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variations, and earth fault. It also includes a feature to inhibit start in case of frequent starting, protecting the motor from overheating. The rated current range is 5-100 A, with protection settings adjustable for various parameters including thermal overload, motor temperature, phase imbalance, phase failure, and more. The supply voltage is 24 V DC, with a rated voltage for AC phase-to-phase operation at 690 V (50-60Hz). Measurement functions cover a wide range of current and temperature parameters, ensuring comprehensive monitoring and protection for connected motors.
Product Details
- Protection Type Thermal protection Reverse polarity protection Phase unbalance Phase failure Overload (long time) Thermal overload protection Load fluctuation Power factor variation Earth-leakage protection Locked rotor O
- Network And Machine Diagnosis Type Motor control command recording Trip context information Starting current and time Event recording Fault recording Remaining operating time before overload tripping Phase fault and earth fault trip counters Waiting time
- Measurement Accuracy 5...15 % earth fault current internal measurement 1 % voltage 100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 Temperature 5 % active and reactive power 0,02
- Metering Type Imbalance current Earth-fault current Temperature Phase current I1, I2, I3 RMS Average current Iavg
- Electromagnetic Compatibility Electrostatic discharge, 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2) Radiated RF fields, 3 10 V/m)EN/IEC 61000-4-3) Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4) Fast transients immunity test, level 4 4 kV)EN/IEC 61000-4-4)
- Connections - Terminals
Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.00…0.00 in² (0.25…2- [Uimp] Rated Impulse Withstand Voltage
6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV communication circuit EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1- [Ui] Rated Insulation Voltage
690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508- Load Current
5 A 250 V AC logic output 5 A 30 V DC logic output- Contacts Type And Composition
1 NO + 1 NC fault signal 3 NO- Permissible Power
480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output)- Associated Fuse Rating
4 A gG output 0.5 A gG control circuit- Bus Type
CANopen ISO 1198 1...127 10...1000 kbit/s, SUB-D 9 4 twisted shielded pairs cable CANopen ISO 1198 1...127 10...1000 kbit/s, terminal block 4 twisted shielded pairs cable- Compatibility Code
LTMR- Net Weight
1.17 lb(US) (0.53 kg)- Depth
4.82 in (122.5 mm)- Height
2.40 in (61 mm)- Pollution Degree
3- Web Services
Web server- Tightening Torque
Control circuit 4.43…5.31 lbf.in (0.5…0.6 N.m) flat 0.12 in (3 mm)- Width
3.58 in (91 mm)- Overvoltage Category
III- Connection Pitch
0.20 in (5.08 mm)- Maximum Operating Rate
1800 cyc/h- Current State 1 Guaranteed
Logic input < 15 V 2...15 mA 15 ms- Current State 0 Guaranteed
Logic input < 5 V <= 15 mA 5 ms- Maximum Output Switching Frequency
2 Hz- Logic Input Number
6- Input Current
7 mA- Short-Circuit Withstand
100 kA EN/IEC 60947-4-1- Communication Port Protocol
CANopen- Product Name
TeSys T- Supply Voltage Limits
20.4…26.24 V DC- Measurement Current
5…100 A- Device Application
Equipment monitoring and control- Range
TeSys- Current Consumption
56...127 mA- Device Short Name
LTMR- Product Or Component Type
Motor controller- [Us] Rated Supply Voltage
24 V DCProduct condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
LTMR100CBD Related Documents
Similar products from: Schneider Electric Industrial Automation Components
Manufacturer warranty
LTMR100CBD Schneider Electric
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Worldwide Shipping and Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
- Connections - Terminals
Compare LTMR100CBD with other Industrial Automation Components products
Protection Type
Network And Machine Diagn...
Measurement Accuracy
Metering Type
Electromagnetic Compatibi...
Connections - Terminals
[Uimp] Rated Impulse With...
[Ui] Rated Insulation Vol...
Load Current
Contacts Type And Composi...
Selected product

LTMR100CBD
Schneider Electric
Schneider Electric LTMR100CBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive m...
Protection TypeThermal protection Reverse p...
Network And Machine Diagnosis TypeMotor control command record...
Measurement Accuracy5...15 % earth fault current...
Metering TypeImbalance current Earth-faul...
Electromagnetic CompatibilityElectrostatic discharge, 3 8...
Connections - TerminalsControl circuit connector 1 ...
[Uimp] Rated Impulse Withstand Voltage6 kV current or voltage meas...
[Ui] Rated Insulation Voltage690 V EN/IEC 60947-1 690 V C...
Load Current5 A 250 V AC logic output 5 ...
Contacts Type And Composition1 NO + 1 NC fault signal 3 N...
About the manufacturer
Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...
Recently viewed products
Relevant products
FAQ
Out if stock but available for backorder.
Schneider Electric LTMR100CBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation through a network. The operating modes it accommodates are Overload, Independent, Reverser, 2-step, 2-speed, and a customizable "Custom" mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics such as protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and a detailed fault history. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor, current, and voltage connections, as well as motor control commands and loss of communication. Motor statistics provided include the number of motor control commands, operating time, number of starts per hour, last start I max, and duration of last start. Thermal overload statistics offer insights into time to trip and time to restart, while system operating statistics cover run, on, start, alarm, and fault statuses. The LTMR100CBD uses 3 measurement current transformers with a screw-clamp connection type and operates on the CANopen communication protocol. It is a 3 Pole device with protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variations, and earth fault. It also includes a feature to inhibit start in case of frequent starting, protecting the motor from overheating. The rated current range is 5-100 A, with protection settings adjustable for various parameters including thermal overload, motor temperature, phase imbalance, phase failure, and more. The supply voltage is 24 V DC, with a rated voltage for AC phase-to-phase operation at 690 V (50-60Hz). Measurement functions cover a wide range of current and temperature parameters, ensuring comprehensive monitoring and protection for connected motors.
Similar products from: Industrial Automation Components
What can I help you find today?