Schneider Electric LTMR100CBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation through a network. The operating modes it accommodates are Overload, Independent, Reverser, 2-step, 2-speed, and a customizable "Custom" mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics such as protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and a detailed fault history. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor, current, and voltage connections, as well as motor control commands and loss of communication. Motor statistics provided include the number of motor control commands, operating time, number of starts per hour, last start I max, and duration of last start. Thermal overload statistics offer insights into time to trip and time to restart, while system operating statistics cover run, on, start, alarm, and fault statuses. The LTMR100CBD uses 3 measurement current transformers with a screw-clamp connection type and operates on the CANopen communication protocol. It is a 3 Pole device with protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variations, and earth fault. It also includes a feature to inhibit start in case of frequent starting, protecting the motor from overheating. The rated current range is 5-100 A, with protection settings adjustable for various parameters including thermal overload, motor temperature, phase imbalance, phase failure, and more. The supply voltage is 24 V DC, with a rated voltage for AC phase-to-phase operation at 690 V (50-60Hz). Measurement functions cover a wide range of current and temperature parameters, ensuring comprehensive monitoring and protection for connected motors.

Product Details

  • Protection Type
    Thermal protection Reverse polarity protection Phase unbalance Phase failure Overload (long time) Thermal overload protection Load fluctuation Power factor variation Earth-leakage protection Locked rotor O
  • Network And Machine Diagnosis Type
    Motor control command recording Trip context information Starting current and time Event recording Fault recording Remaining operating time before overload tripping Phase fault and earth fault trip counters Waiting time
  • Measurement Accuracy
    5...15 % earth fault current internal measurement 1 % voltage 100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 Temperature 5 % active and reactive power 0,02
  • Metering Type
    Imbalance current Earth-fault current Temperature Phase current I1, I2, I3 RMS Average current Iavg
  • Electromagnetic Compatibility
    Electrostatic discharge, 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2) Radiated RF fields, 3 10 V/m)EN/IEC 61000-4-3) Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4) Fast transients immunity test, level 4 4 kV)EN/IEC 61000-4-4)
  • Connections - Terminals
    Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.00…0.00 in² (0.25…2
  • [Uimp] Rated Impulse Withstand Voltage
    6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV communication circuit EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1
  • [Ui] Rated Insulation Voltage
    690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508
  • Load Current
    5 A 250 V AC logic output 5 A 30 V DC logic output
  • Contacts Type And Composition
    1 NO + 1 NC fault signal 3 NO
  • Permissible Power
    480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
  • Associated Fuse Rating
    4 A gG output 0.5 A gG control circuit
  • Bus Type
    CANopen ISO 1198 1...127 10...1000 kbit/s, SUB-D 9 4 twisted shielded pairs cable CANopen ISO 1198 1...127 10...1000 kbit/s, terminal block 4 twisted shielded pairs cable
  • Compatibility Code
    LTMR
  • Net Weight
    1.17 lb(US) (0.53 kg)
  • Depth
    4.82 in (122.5 mm)
  • Height
    2.40 in (61 mm)
  • Pollution Degree
    3
  • Web Services
    Web server
  • Tightening Torque
    Control circuit 4.43…5.31 lbf.in (0.5…0.6 N.m) flat 0.12 in (3 mm)
  • Width
    3.58 in (91 mm)
  • Overvoltage Category
    III
  • Connection Pitch
    0.20 in (5.08 mm)
  • Maximum Operating Rate
    1800 cyc/h
  • Current State 1 Guaranteed
    Logic input < 15 V 2...15 mA 15 ms
  • Current State 0 Guaranteed
    Logic input < 5 V <= 15 mA 5 ms
  • Maximum Output Switching Frequency
    2 Hz
  • Logic Input Number
    6
  • Input Current
    7 mA
  • Short-Circuit Withstand
    100 kA EN/IEC 60947-4-1
  • Communication Port Protocol
    CANopen
  • Product Name
    TeSys T
  • Supply Voltage Limits
    20.4…26.24 V DC
  • Measurement Current
    5…100 A
  • Device Application
    Equipment monitoring and control
  • Range
    TeSys
  • Current Consumption
    56...127 mA
  • Device Short Name
    LTMR
  • Product Or Component Type
    Motor controller
  • [Us] Rated Supply Voltage
    24 V DC

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Similar products from: Schneider Electric Industrial Automation Components

Manufacturer warranty

LTMR100CBD Schneider Electric

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare LTMR100CBD with other Industrial Automation Components products

Protection Type

Network And Machine Diagn...

Measurement Accuracy

Metering Type

Electromagnetic Compatibi...

Connections - Terminals

[Uimp] Rated Impulse With...

[Ui] Rated Insulation Vol...

Load Current

Contacts Type And Composi...

Selected product

LTMR100CBD
Backordered
LTMR100CBD
Schneider Electric

Schneider Electric LTMR100CBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive m...

Protection TypeThermal protection Reverse p...

Network And Machine Diagnosis TypeMotor control command record...

Measurement Accuracy5...15 % earth fault current...

Metering TypeImbalance current Earth-faul...

Electromagnetic CompatibilityElectrostatic discharge, 3 8...

Connections - TerminalsControl circuit connector 1 ...

[Uimp] Rated Impulse Withstand Voltage6 kV current or voltage meas...

[Ui] Rated Insulation Voltage690 V EN/IEC 60947-1 690 V C...

Load Current5 A 250 V AC logic output 5 ...

Contacts Type And Composition1 NO + 1 NC fault signal 3 N...

LC1D326BL
4 in stock
LC1D326BL
Schneider Electric

Schneider Electric LC1D326BL is a magnetic contactor from the Deca sub-range, featuring a low-consum...

Protection Type-

Network And Machine Diagnosis Type-

Measurement Accuracy-

Metering Type-

Electromagnetic Compatibility-

Connections - Terminals-

[Uimp] Rated Impulse Withstand Voltage-

[Ui] Rated Insulation VoltagePower circuit 690 V IEC 6094...

Load Current-

Contacts Type And Composition-

LC1DT20BL
2 in stock
LC1DT20BL
Schneider Electric

Schneider Electric LC1DT20BL is a magnetic contactor from the Deca sub-range, designed with a low-co...

Protection Type-

Network And Machine Diagnosis Type-

Measurement Accuracy-

Metering Type-

Electromagnetic Compatibility-

Connections - Terminals-

[Uimp] Rated Impulse Withstand Voltage-

[Ui] Rated Insulation VoltagePower circuit 600 V CSA Powe...

Load Current-

Contacts Type And Composition-

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

Recently viewed products

Relevant products

LTMR27DBD on Powermatic Associates

LTMR27DBD

Verified stock: 0

Schneider Electric LTMR27DBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation via network. The device offers multiple operating modes such as Overload, Independent, Reverser, 2-step, 2-speed, and Custom mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics like protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, fault history, and more. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor, current, and voltage connections, motor control commands, control configuration checksum, and loss of communication. Motor and thermal overload statistics provide insights into motor control commands, operating time, starts per hour, last start I max, duration of last start, time to trip, and time to restart. System operating statistics cover run, on, start, alarm, and fault statuses. Connection is facilitated through 3 measurement current transformers with a screw-clamp type, utilizing the DeviceNet communication protocol. It is a 3 Pole device with protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variations, and earth fault. The rated current ranges from 1.35-27 A with protection settings adjustable for various conditions. Supply voltage is DC 24 V, with a rated voltage for AC phase-to-phase at 50-60Hz 690 V. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise, catering to a broad spectrum of monitoring and protection needs.

Schneider Electric

LTMR100MBD on Powermatic Associates

LTMR100MBD

Verified stock: 0

Schneider Electric LTMR100MBD, part of the LTMR (TeSys T) sub-range, is designed for motor management with a variety of control modes including local via terminal block, local via HMI terminal, and remote via network. It supports operating modes such as overload, independent, reverser, 2-step, 2-speed, and custom mode. The part offers comprehensive fault management capabilities with manual, automatic, and remote reset options, alongside protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and fault history. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor connection, current connection, voltage connection, motor control commands, control configuration checksum, and loss of communication. Motor statistics provided include the number of motor control commands, operating time, number of starts per hour, last start I max, and duration of last start. Thermal overload statistics cover time to trip and time to restart, while system operating statistics include run, on, start, alarm, and fault indicators. The connection type is 3 measurement current transformers with screw-clamp terminals, and it uses the Modbus communication protocol. It is a 3 Pole device with protection functions for thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variation, earth fault, and frequent starting. Rated current ranges from 5-100 A with protection settings adjustable for various conditions. The supply voltage is 24 V DC, and the rated voltage for AC phase-to-phase is up to 690 V at 50-60Hz. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise, accommodating a wide range of monitoring and protection needs for motor management.

Schneider Electric

LTMR27PFM on Powermatic Associates

LTMR27PFM

Verified stock: 0

Schneider Electric LTMR27PFM, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation through a network. The operating modes it accommodates are Overload, Independent, Reverser, 2-step, 2-speed, and a customizable "Custom" mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics such as protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and a detailed fault history. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor, current, and voltage connections, motor control commands, control configuration checksum, and loss of communication. Motor and thermal overload statistics provide insights into motor control commands, operating time, starts per hour, last start current max, duration of last start, time to trip, and time to restart. System operating statistics cover run, on, start, alarm, and fault statuses. The connection type is a 3 measurement current transformer control circuit with screw-clamp terminals, utilizing the Profibus communication protocol. It is a 3 Pole device with protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variations, earth fault, and frequent starting. The rated current ranges from 1.35-27 A with protection settings adjustable for various conditions. Supply voltage is AC 100-240 V, with a rated voltage for phase-to-phase at 50-60Hz being 690 V. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise, ensuring comprehensive monitoring and protection for motor applications.

Schneider Electric

LTMR27DFM on Powermatic Associates

LTMR27DFM

Verified stock: 0

Schneider Electric LTMR27DFM, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation through a network. The LTMR27DFM offers multiple operating modes such as Overload, Independent, Reverser, 2-step, 2-speed, and Custom mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics like protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and fault history. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor connection, current connection, voltage connection, motor control commands, control configuration checksum, and loss of communication. Motor statistics provided include the number of motor control commands, operating time, number of starts per hour, last start I max, and duration of last start. Thermal overload statistics cover time to trip and time to restart, while system operating statistics monitor run, on, start, alarm, and fault statuses. The LTMR27DFM utilizes 3 measurement current transformers with a screw-clamp connection type and supports the DeviceNet communication protocol. It is a 3 Pole device with protection functions for thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variation, earth fault, and frequent starting. Rated current ranges from 1.35-27 A with protection settings adjustable for various parameters. Supply voltage is AC 100-240 V, with a rated voltage (AC) phase-to-phase of 690 V at 50-60Hz. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise.

Schneider Electric

LTMR08MBD on Powermatic Associates

LTMR08MBD

Verified stock: 0

Schneider Electric LTMR08MBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management including control modes such as local via terminal block, local via HMI terminal, and remote via network. It supports various operating modes including overload, independent, reverser, 2-step, 2-speed, and custom mode. The device offers fault management features like manual, automatic, and remote reset, alongside protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, fault history, and diagnostics for internal watchdog fault, controller internal temperature, temperature sensor connection, current connection, voltage connection, motor control commands, control configuration checksum, and loss of communication. It records motor statistics like the number of motor control commands, operating time, number of starts per hour, last start I max, duration of last start, and thermal overload statistics including time to trip and time to restart. System operating statistics such as run, on, start, alarm, and fault are also tracked. The LTMR08MBD features a 3-pole connection with 3 measurement current transformers (control circuit) using screw-clamp terminals and communicates via the Modbus protocol. It offers protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variation, earth fault, and frequent starting. The device is rated for currents from 0.4 to 8 A (maximum with CT) 800 A, with protection settings adjustable for various parameters. It operates on a supply voltage of 24 V DC and a rated voltage (AC) phase-to-phase of 690 V at 50-60Hz, with a minimum current of 0.4 A and a maximum of 8 A. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise.

Schneider Electric

FAQ

Out if stock but available for backorder.

Schneider Electric LTMR100CBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation through a network. The operating modes it accommodates are Overload, Independent, Reverser, 2-step, 2-speed, and a customizable "Custom" mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics such as protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and a detailed fault history. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor, current, and voltage connections, as well as motor control commands and loss of communication. Motor statistics provided include the number of motor control commands, operating time, number of starts per hour, last start I max, and duration of last start. Thermal overload statistics offer insights into time to trip and time to restart, while system operating statistics cover run, on, start, alarm, and fault statuses. The LTMR100CBD uses 3 measurement current transformers with a screw-clamp connection type and operates on the CANopen communication protocol. It is a 3 Pole device with protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variations, and earth fault. It also includes a feature to inhibit start in case of frequent starting, protecting the motor from overheating. The rated current range is 5-100 A, with protection settings adjustable for various parameters including thermal overload, motor temperature, phase imbalance, phase failure, and more. The supply voltage is 24 V DC, with a rated voltage for AC phase-to-phase operation at 690 V (50-60Hz). Measurement functions cover a wide range of current and temperature parameters, ensuring comprehensive monitoring and protection for connected motors.

Similar products from: Industrial Automation Components

What can I help you find today?

Recommended parts