LTMR100EBD Schneider Electric Industrial Automation Components

LTMR100EBD on Powermatic Associates
Schneider Electric

Part#:LTMR100EBD

Manufacturer:Schneider Electric

Category:Industrial Automation Components

Product Lifecycle:Active

Product description

Schneider Electric LTMR100EBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation through a network. The operating modes it accommodates are Overload, Independent, Reverser, 2-step, 2-speed, and a customizable "Custom" mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics such as protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and a fault history log. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor, current, and voltage connections, as well as motor control commands and a control configuration checksum. The LTMR100EBD also monitors loss of communication and provides detailed motor and thermal overload statistics, including the number of motor control commands, operating time, number of starts per hour, and the duration and intensity of the last start. System operating statistics cover run, on, start, alarm, and fault statuses. Connection is facilitated through 3 measurement current transformers with a screw-clamp control circuit. It uses an Ethernet TCP/IP Modbus TCP communication protocol and is designed for 3 Pole(s) configurations. Protection functions include thermal overload, motor temperature monitoring with up to 3 sensors, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variations, and earth fault detection. It supports frequent starting protection to prevent motor overheating. Rated for a current range of 5-100 A, it offers adjustable protection settings for thermal overload, motor temperature, phase imbalance and failure, phase reversal, long starting time, locked rotor, current load limit variations, and earth faults. The supply voltage is DC 24 V, with a phase-to-phase rated voltage for AC at 50-60Hz up to 690 V. The minimum current capability is 5 A, and the maximum is 100 A. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise, covering a broad range of monitoring needs.

Product Details

  • Protection Type
    Locked rotor Overload Thermal overload protection Earth-leakage protection Reverse polarity protection Overload (long time) Power factor variation Phase unbalance Load fluctuation Phase failure Thermal pro
  • Network And Machine Diagnosis Type
    Fault recording Trip context information Waiting time after overload tripping Trip history information Running hours counter/operating time Motor control command recording Starting current and time Phase fault and earth
  • Measurement Accuracy
    5...15 % earth fault current internal measurement 1 % voltage 100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 Temperature 5 % active and reactive power 0,02
  • Metering Type
    Average current Iavg Earth-fault current Temperature Phase current I1, I2, I3 RMS Imbalance current
  • Electromagnetic Compatibility
    Electrostatic discharge, 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2) Radiated RF fields, 3 10 V/m)EN/IEC 61000-4-3) Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4) Fast transients immunity test, level 4 4 kV)EN/IEC 61000-4-4)
  • [Uimp] Rated Impulse Withstand Voltage
    6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV communication circuit EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1
  • Connections - Terminals
    Control circuit connector 1 0.00…0.00 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.00…0.00 in² (0.25…2
  • [Ui] Rated Insulation Voltage
    690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508
  • Permissible Power
    480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
  • Associated Fuse Rating
    4 A gG output 0.5 A gG control circuit
  • Contacts Type And Composition
    1 NO + 1 NC fault signal 3 NO
  • Load Current
    5 A 250 V AC logic output 5 A 30 V DC logic output
  • Web Services
    Web server
  • Compatibility Code
    LTMR
  • Net Weight
    1.17 lb(US) (0.53 kg)
  • Height
    2.40 in (61 mm)
  • Width
    3.58 in (91 mm)
  • Tightening Torque
    Control circuit 4.43…5.31 lbf.in (0.5…0.6 N.m) flat 0.12 in (3 mm)
  • Pollution Degree
    3
  • Connection Pitch
    0.20 in (5.08 mm)
  • Depth
    4.82 in (122.5 mm)
  • Overvoltage Category
    III
  • Maximum Operating Rate
    1800 cyc/h
  • Maximum Output Switching Frequency
    2 Hz
  • Current State 1 Guaranteed
    Logic input < 15 V 2...15 mA 15 ms
  • Current State 0 Guaranteed
    Logic input < 5 V <= 15 mA 5 ms
  • Logic Input Number
    6
  • Input Current
    7 mA
  • Short-Circuit Withstand
    100 kA EN/IEC 60947-4-1
  • Communication Port Protocol
    Modbus TCP/EtherNet/IP
  • Bus Type
    Ethernet IEEE 802.3 0...159 10...100 Mbit/s, RJ45 2 shielded twisted pairs
  • Supply Voltage Limits
    20.4…26.24 V DC
  • Current Consumption
    56...127 mA
  • [Us] Rated Supply Voltage
    24 V DC
  • Measurement Current
    5…100 A
  • Device Application
    Equipment monitoring and control
  • Product Or Component Type
    Motor controller
  • Device Short Name
    LTMR
  • Product Name
    TeSys T
  • Range
    TeSys

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LTMR100EBD on Powermatic Associates is $1,014.76. Order now.



Similar products from: Schneider Electric Industrial Automation Components

Manufacturer warranty

LTMR100EBD Schneider Electric

$1,014.76

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,014.76

$1,014.76 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare LTMR100EBD with other Industrial Automation Components products

Protection Type

Network And Machine Diagn...

Measurement Accuracy

Metering Type

Electromagnetic Compatibi...

[Uimp] Rated Impulse With...

Connections - Terminals

[Ui] Rated Insulation Vol...

Permissible Power

Associated Fuse Rating

Selected product

LTMR100EBD
Backordered
LTMR100EBD
Schneider Electric

Schneider Electric LTMR100EBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive m...

Protection TypeLocked rotor Overload Therma...

Network And Machine Diagnosis TypeFault recording Trip context...

Measurement Accuracy5...15 % earth fault current...

Metering TypeAverage current Iavg Earth-f...

Electromagnetic CompatibilityElectrostatic discharge, 3 8...

[Uimp] Rated Impulse Withstand Voltage6 kV current or voltage meas...

Connections - TerminalsControl circuit connector 1 ...

[Ui] Rated Insulation Voltage690 V EN/IEC 60947-1 690 V C...

Permissible Power480 VA AC-15), Ie = 2 A, 500...

Associated Fuse Rating4 A gG output 0.5 A gG contr...

LC1D326BL
4 in stock
LC1D326BL
Schneider Electric

Schneider Electric LC1D326BL is a magnetic contactor from the Deca sub-range, featuring a low-consum...

Protection Type-

Network And Machine Diagnosis Type-

Measurement Accuracy-

Metering Type-

Electromagnetic Compatibility-

[Uimp] Rated Impulse Withstand Voltage-

Connections - Terminals-

[Ui] Rated Insulation VoltagePower circuit 690 V IEC 6094...

Permissible Power-

Associated Fuse Rating-

LC1DT20BL
2 in stock
LC1DT20BL
Schneider Electric

Schneider Electric LC1DT20BL is a magnetic contactor from the Deca sub-range, designed with a low-co...

Protection Type-

Network And Machine Diagnosis Type-

Measurement Accuracy-

Metering Type-

Electromagnetic Compatibility-

[Uimp] Rated Impulse Withstand Voltage-

Connections - Terminals-

[Ui] Rated Insulation VoltagePower circuit 600 V CSA Powe...

Permissible Power-

Associated Fuse Rating-

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

Recently viewed products

Relevant products

LTMR27DBD on Powermatic Associates

LTMR27DBD

Verified stock: 0

Schneider Electric LTMR27DBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation via network. The device offers multiple operating modes such as Overload, Independent, Reverser, 2-step, 2-speed, and Custom mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics like protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, fault history, and more. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor, current, and voltage connections, motor control commands, control configuration checksum, and loss of communication. Motor and thermal overload statistics provide insights into motor control commands, operating time, starts per hour, last start I max, duration of last start, time to trip, and time to restart. System operating statistics cover run, on, start, alarm, and fault statuses. Connection is facilitated through 3 measurement current transformers with a screw-clamp type, utilizing the DeviceNet communication protocol. It is a 3 Pole device with protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variations, and earth fault. The rated current ranges from 1.35-27 A with protection settings adjustable for various conditions. Supply voltage is DC 24 V, with a rated voltage for AC phase-to-phase at 50-60Hz 690 V. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise, catering to a broad spectrum of monitoring and protection needs.

Schneider Electric

LTMR100MBD on Powermatic Associates

LTMR100MBD

Verified stock: 0

Schneider Electric LTMR100MBD, part of the LTMR (TeSys T) sub-range, is designed for motor management with a variety of control modes including local via terminal block, local via HMI terminal, and remote via network. It supports operating modes such as overload, independent, reverser, 2-step, 2-speed, and custom mode. The part offers comprehensive fault management capabilities with manual, automatic, and remote reset options, alongside protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and fault history. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor connection, current connection, voltage connection, motor control commands, control configuration checksum, and loss of communication. Motor statistics provided include the number of motor control commands, operating time, number of starts per hour, last start I max, and duration of last start. Thermal overload statistics cover time to trip and time to restart, while system operating statistics include run, on, start, alarm, and fault indicators. The connection type is 3 measurement current transformers with screw-clamp terminals, and it uses the Modbus communication protocol. It is a 3 Pole device with protection functions for thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variation, earth fault, and frequent starting. Rated current ranges from 5-100 A with protection settings adjustable for various conditions. The supply voltage is 24 V DC, and the rated voltage for AC phase-to-phase is up to 690 V at 50-60Hz. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise, accommodating a wide range of monitoring and protection needs for motor management.

Schneider Electric

LTMR27PFM on Powermatic Associates

LTMR27PFM

Verified stock: 0

Schneider Electric LTMR27PFM, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation through a network. The operating modes it accommodates are Overload, Independent, Reverser, 2-step, 2-speed, and a customizable "Custom" mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics such as protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and a detailed fault history. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor, current, and voltage connections, motor control commands, control configuration checksum, and loss of communication. Motor and thermal overload statistics provide insights into motor control commands, operating time, starts per hour, last start current max, duration of last start, time to trip, and time to restart. System operating statistics cover run, on, start, alarm, and fault statuses. The connection type is a 3 measurement current transformer control circuit with screw-clamp terminals, utilizing the Profibus communication protocol. It is a 3 Pole device with protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variations, earth fault, and frequent starting. The rated current ranges from 1.35-27 A with protection settings adjustable for various conditions. Supply voltage is AC 100-240 V, with a rated voltage for phase-to-phase at 50-60Hz being 690 V. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise, ensuring comprehensive monitoring and protection for motor applications.

Schneider Electric

LTMR27DFM on Powermatic Associates

LTMR27DFM

Verified stock: 0

Schneider Electric LTMR27DFM, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation through a network. The LTMR27DFM offers multiple operating modes such as Overload, Independent, Reverser, 2-step, 2-speed, and Custom mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics like protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and fault history. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor connection, current connection, voltage connection, motor control commands, control configuration checksum, and loss of communication. Motor statistics provided include the number of motor control commands, operating time, number of starts per hour, last start I max, and duration of last start. Thermal overload statistics cover time to trip and time to restart, while system operating statistics monitor run, on, start, alarm, and fault statuses. The LTMR27DFM utilizes 3 measurement current transformers with a screw-clamp connection type and supports the DeviceNet communication protocol. It is a 3 Pole device with protection functions for thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variation, earth fault, and frequent starting. Rated current ranges from 1.35-27 A with protection settings adjustable for various parameters. Supply voltage is AC 100-240 V, with a rated voltage (AC) phase-to-phase of 690 V at 50-60Hz. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise.

Schneider Electric

LTMR100CBD on Powermatic Associates

LTMR100CBD

Verified stock: 0

Schneider Electric LTMR100CBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation through a network. The operating modes it accommodates are Overload, Independent, Reverser, 2-step, 2-speed, and a customizable "Custom" mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics such as protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and a detailed fault history. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor, current, and voltage connections, as well as motor control commands and loss of communication. Motor statistics provided include the number of motor control commands, operating time, number of starts per hour, last start I max, and duration of last start. Thermal overload statistics offer insights into time to trip and time to restart, while system operating statistics cover run, on, start, alarm, and fault statuses. The LTMR100CBD uses 3 measurement current transformers with a screw-clamp connection type and operates on the CANopen communication protocol. It is a 3 Pole device with protection functions against thermal overload, motor temperature, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variations, and earth fault. It also includes a feature to inhibit start in case of frequent starting, protecting the motor from overheating. The rated current range is 5-100 A, with protection settings adjustable for various parameters including thermal overload, motor temperature, phase imbalance, phase failure, and more. The supply voltage is 24 V DC, with a rated voltage for AC phase-to-phase operation at 690 V (50-60Hz). Measurement functions cover a wide range of current and temperature parameters, ensuring comprehensive monitoring and protection for connected motors.

Schneider Electric

FAQ

What is the price of LTMR100EBD?
Purchase the LTMR100EBD from Powermatic Associates at the price of $1,014.76. Order today.

Out if stock but available for backorder.

Schneider Electric LTMR100EBD, part of the LTMR (TeSys T) sub-range, is designed for comprehensive motor management and protection. It supports various control modes including local operation via terminal block or HMI terminal, and remote operation through a network. The operating modes it accommodates are Overload, Independent, Reverser, 2-step, 2-speed, and a customizable "Custom" mode. Fault management capabilities include manual, automatic, and remote reset options, alongside extensive fault statistics such as protection fault counters, protection alarm counters, diagnostic fault counters, motor control function counters, and a fault history log. It features fault diagnostics for internal watchdog faults, controller internal temperature, temperature sensor, current, and voltage connections, as well as motor control commands and a control configuration checksum. The LTMR100EBD also monitors loss of communication and provides detailed motor and thermal overload statistics, including the number of motor control commands, operating time, number of starts per hour, and the duration and intensity of the last start. System operating statistics cover run, on, start, alarm, and fault statuses. Connection is facilitated through 3 measurement current transformers with a screw-clamp control circuit. It uses an Ethernet TCP/IP Modbus TCP communication protocol and is designed for 3 Pole(s) configurations. Protection functions include thermal overload, motor temperature monitoring with up to 3 sensors, phase imbalance, phase failure, phase reversal, long starting time, locked rotor, minimum and maximum current load limit variations, and earth fault detection. It supports frequent starting protection to prevent motor overheating. Rated for a current range of 5-100 A, it offers adjustable protection settings for thermal overload, motor temperature, phase imbalance and failure, phase reversal, long starting time, locked rotor, current load limit variations, and earth faults. The supply voltage is DC 24 V, with a phase-to-phase rated voltage for AC at 50-60Hz up to 690 V. The minimum current capability is 5 A, and the maximum is 100 A. Measurement functions include current/phase, earth current, average current, current imbalance between phases, thermal capacity level, and motor temperature rise, covering a broad range of monitoring needs.

Similar products from: Industrial Automation Components

What can I help you find today?

Recommended parts